Twenty-five Pitfalls in the Analysis of Diffusion MRI Data

被引:631
作者
Jones, Derek K. [1 ]
Cercignani, Mara [2 ]
机构
[1] Cardiff Univ, CUBRIC, Sch Psychol, Brain Res Imaging Ctr, Cardiff CF10 3AT, S Glam, Wales
[2] Santa Lucia Fdn, IRCCS, Neuroimaging Lab, Rome, Italy
关键词
diffusion tensor MRI; registration; distortion; spatial normalization; analysis; statistics; artefacts; voxel-based analysis; VOXEL-BASED MORPHOMETRY; ECHO-PLANAR IMAGES; HUMAN BRAIN; TENSOR MRI; WHITE-MATTER; SPATIAL STATISTICS; SPIN-ECHO; ANISOTROPY; DISTORTION; TRACTOGRAPHY;
D O I
10.1002/nbm.1543
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Obtaining reliable data and drawing meaningful and robust inferences from diffusion MRI can be challenging and is subject to many pitfalls. The process of quantifying diffusion indices and eventually comparing them between groups of subjects and/or correlating them with other parameters starts at the acquisition of the raw data, followed by a long pipeline of image processing steps. Each one of these steps is susceptible to sources of bias, which may not only limit the accuracy and precision, but can lead to substantial errors. This article provides a detailed review of the steps along the analysis pipeline and their associated pitfalls. These are grouped into (1) pre-processing of data; (2) estimation of the tensor; (3) derivation of voxelwise quantitative parameters; (4) strategies for extracting quantitative parameters; and finally (5) intra-subject and inter-subject comparison, including region of interest, histogram, tract-specific and voxel-based analyses. The article covers important aspects of diffusion MRI analysis, such as motion correction, susceptibility and eddy current distortion correction, model fitting, region of interest placement, histogram and voxel-based analysis. We have assembled 25 pitfalls (several previously unreported) into a single article, which should serve as a useful reference for those embarking on new diffusion MRI-based studies, and as a check for those who may already be running studies but may have overlooked some important confounds. While some of these problems are well known to diffusion experts, they might not be to other researchers wishing to undertake a clinical study based on diffusion MRI. Copyright (C) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:803 / 820
页数:18
相关论文
共 80 条
  • [1] Spatial transformations of diffusion tensor magnetic resonance images
    Alexander, DC
    Pierpaoli, C
    Basser, PJ
    Gee, JC
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (11) : 1131 - 1139
  • [2] Andersson JL, 2004, P INT SOC MAGN RES M, P87
  • [3] A model-based method for retrospective correction of geometric distortions in diffusion-weighted EPI
    Andersson, JLR
    Skare, S
    [J]. NEUROIMAGE, 2002, 16 (01) : 177 - 199
  • [4] Voxel-based morphometry - The methods
    Ashburner, J
    Friston, KJ
    [J]. NEUROIMAGE, 2000, 11 (06) : 805 - 821
  • [5] Why voxel-based morphometry should be used
    Ashburner, J
    Friston, KJ
    [J]. NEUROIMAGE, 2001, 14 (06) : 1238 - 1243
  • [6] Diffusion tensor imaging using single-shot SENSE-EPI
    Bammer, R
    Auer, M
    Keeling, SL
    Augustin, M
    Stables, LA
    Prokesch, RW
    Stollberger, R
    Moseley, ME
    Fazekas, F
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (01) : 128 - 136
  • [7] MR DIFFUSION TENSOR SPECTROSCOPY AND IMAGING
    BASSER, PJ
    MATTIELLO, J
    LEBIHAN, D
    [J]. BIOPHYSICAL JOURNAL, 1994, 66 (01) : 259 - 267
  • [8] ESTIMATION OF THE EFFECTIVE SELF-DIFFUSION TENSOR FROM THE NMR SPIN-ECHO
    BASSER, PJ
    MATTIELLO, J
    LEBIHAN, D
    [J]. JOURNAL OF MAGNETIC RESONANCE SERIES B, 1994, 103 (03): : 247 - 254
  • [9] Correction of eddy current-induced artefacts in diffusion tensor imaging using iterative cross-correlation
    Bastin, ME
    [J]. MAGNETIC RESONANCE IMAGING, 1999, 17 (07) : 1011 - 1024
  • [10] Bevington P. R., 2002, Data reduction and error analysis for the physical sciences