A Fast Response Strontium(II) Selective Polymeric Membrane Sensor Based on 1-Benzothiazol-3-Benzoyl-Thiocarbamide as Neutral Carrier

被引:2
作者
Guo, Junxiang [1 ]
Chai, Yaqin [1 ]
Yuan, Ruo [1 ]
Ma, Yuhua [1 ]
Zou, Zhifen [1 ]
机构
[1] Southwest Univ, Coll Chem & Chem Engn, Minist Educ, Key Lab Luminescence & Real Time Anal, Chongqing 400715, Peoples R China
基金
中国国家自然科学基金;
关键词
Membrane Sensor; Neutral Carrier; PVC Membrane; Ion Selective Electrode; Potentiometry; POTENTIOMETRIC SENSOR; MASS-SPECTROMETRY; LEVEL DETECTION; URANYL IONS; PVC MATRIX; ELECTRODES; CONSTRUCTION; ADDITIVES; DIAMIDES; METALS;
D O I
10.1166/sl.2010.1317
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new selective strontium(II) PVC membrane sensor based on the 1-benzothiazol-3-benzoyl-thiocarbamide (BTBTA) ligand as neutral ionophore has been developed. The sensor exhibits Nernstian potential linear range to Sr2+ from 4.0 x 10(-7) moth. to 1.0 x 10(-1) mol/L with a detection limit of 2.5 x 10(-7) mol/L and a slope of 30.1 +/- 0.1 mV/decade of activity in a pH range of 3.0-8.0. It showed a response time of less than 10 s and could be used for at least 3 months without any considerable divergence in potentials. The proposed sensor showed a good discriminating ability towards strontium(II) ion over a wide variety of other metal ions including alkali, alkaline earth, transition and heavy metal ions. The response mechanism was discussed in view of the AC impedance and UV-visible spectroscopic techniques. It was used as an indicator electrode in potentiometric titration of strontium ion against EDTA. At the same time the sensor was successfully applied to the determination of strontium ions in soil and tea.
引用
收藏
页码:596 / 601
页数:6
相关论文
共 43 条
[1]   Barium(II)-PVC membrane sensor based on 4-4′-methylenediantipyrine as a neutral carrier [J].
Abedi, Mohammad Reza ;
Zamani, Hassan Ali .
ANALYTICAL LETTERS, 2008, 41 (12) :2251-2266
[2]  
Amarchand S, 2000, ELECTROANAL, V12, P522, DOI 10.1002/(SICI)1521-4109(200005)12:7<522::AID-ELAN522>3.3.CO
[3]  
2-4
[4]   LIPOPHILIC SALTS AS MEMBRANE ADDITIVES AND THEIR INFLUENCE ON THE PROPERTIES OF MACROELECTRODES AND MICROELECTRODES BASED ON NEUTRAL CARRIERS [J].
AMMANN, D ;
PRETSCH, E ;
SIMON, W ;
LINDNER, E ;
BEZEGH, A ;
PUNGOR, E .
ANALYTICA CHIMICA ACTA, 1985, 171 (MAY) :119-129
[5]   Atomic spectrometry update. Atomic mass spectrometry [J].
Bacon, Jeffrey R. ;
Linge, Kathryn L. ;
Parrish, Randall R. ;
Van Vaeck, Luc .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2008, 23 (08) :1130-1162
[6]  
DOROTHY C, 1955, CHEM REV, V55, P181
[7]   Microwave digestion of plant and grain standard reference materials in nitric and hydrofluoric acids for multi-elemental determination by inductively coupled plasma mass spectrometry [J].
Feng, XB ;
Wu, SL ;
Wharmby, A ;
Wittmeier, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (06) :939-946
[8]   Novel lanthanum(III) membrane sensor based on a new N-S Schiff's base [J].
Ganjali, MR ;
Qomi, M ;
Daftari, A ;
Norouzi, P ;
Salavati-Niasari, M ;
Rabbani, M .
SENSORS AND ACTUATORS B-CHEMICAL, 2004, 98 (01) :92-96
[9]  
Ganjali MR, 2004, ANAL SCI, V20, P1007
[10]   Gliclazide as novel carrier in construction of PVC-based La(III)-selective membrane sensor [J].
Ganjali, MR ;
Daftari, A ;
Rezapour, M ;
Puorsaberi, T ;
Haghgoo, S .
TALANTA, 2003, 59 (03) :613-619