A comparison of two methods of heart rate variability assessment at high altitude

被引:17
作者
Boos, Christopher John [1 ,2 ]
Bakker-Dyos, Josh [3 ]
Watchorn, Jim [3 ]
Woods, David Richard [3 ,4 ,5 ,6 ]
O'Hara, John Paul [4 ]
Macconnachie, Lee [1 ]
Mellor, Adrian [3 ,4 ,7 ]
机构
[1] Poole Hosp NHS Fdn Trust, Dept Cardiol, Longfleet Rd, Poole BH15 2JB, Dorset, England
[2] Bournemouth Univ, Dept Postgrad Med Educ, Bournemouth, Dorset, England
[3] Def Med Serv, Lichfield, England
[4] Leeds Beckett Univ, Res Inst Sport Phys Act & Leisure, Leeds, W Yorkshire, England
[5] Wansbeck Gen & Royal Victoria Infirm, Northumbria & Newcastle NHS Trusts, Newcastle, England
[6] Univ Newcastle, Newcastle Upon Tyne, Tyne & Wear, England
[7] James Cook Univ Hosp, Middlesbrough, England
关键词
CheckMyHeart; heart rate variability; high altitude; ithlete; AUTONOMIC ACTIVITY; AGREEMENT; EXPOSURE; INDEXES;
D O I
10.1111/cpf.12334
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Heart rate variability (HRV) is a useful index of autonomic function and has been linked to the development of high altitude (HA) related illness. However, its assessment at HA has been undermined by the relative expense and limited portability of traditional HRV devices which have mandated at least a minute heart rate recording. In this study, the portable ithlete (TM) HRV system, which uses a 55 s recording, was compared with a reference method of HRV which utilizes a 5 min electrocardiograph recording (CheckMyHeart (TM)). The root mean squares of successive R-R intervals (RMSSD) for each device was converted to a validated HRV score (lnRMSSD 9 20) for comparison. Twelve healthy volunteers were assessed for HRV using the two devices across seven time points at HA over 10 days. There was no significant change in the HRV values with either the ithlete (P = 0.3) or the CheckMyHeart (TM) (P = 0.19) device over the seven altitudes. There was also a strong overall correlation between the ithlete (TM) and CheckMyHeart (TM) device (r = 0.86; 95% confidence interval: 0.79-0.91). The HRV was consistently, though non-significantly higher with ithlete (TM) than with the CheckMyHeart (TM) device [mean difference (bias) 1.8 l; 95% CI-12.3 to 8.5]. In summary, the ithlete (TM) and CheckMyHeart (TM) system provide relatively similar results with good overall agreement at HA.
引用
收藏
页码:582 / 587
页数:6
相关论文
共 28 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   Heart rate variability and arterial oxygen saturation response during extreme normobaric hypoxia [J].
Botek, Michal ;
Krejci, Jakub ;
De Smet, Stefan ;
Gaba, Ales ;
McKune, Andrew J. .
AUTONOMIC NEUROSCIENCE-BASIC & CLINICAL, 2015, 190 :40-45
[3]  
Camm AJ, 1996, CIRCULATION, V93, P1043
[4]   Effect of Rapid Ascent to High Altitude on Autonomic Cardiovascular Modulation [J].
Chen, Yi-Chu ;
Lin, Fang-Chi ;
Shiao, Guang-Ming ;
Chang, Shi-Chuan .
AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 2008, 336 (03) :248-253
[5]   Serious Altitude Illness in Travelers Who Visited a Pre-Travel Clinic [J].
Croughs, Mieke ;
Van Gompel, Alfons ;
Rameckers, Sarah ;
Van den Ende, Jef .
JOURNAL OF TRAVEL MEDICINE, 2014, 21 (06) :403-409
[6]   Precompetitive assessment of heart rate variability in elite female athletes during play offs [J].
D'Ascenzi, Flavio ;
Alvino, Federico ;
Natali, Benedetta M. ;
Cameli, Matteo ;
Palmitesta, Paola ;
Boschetti, Giampaolo ;
Bonifazi, Marco ;
Mondillo, Sergio .
CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2014, 34 (03) :230-236
[7]   Heart Rate Variability Indexes as a Marker of Chronic Adaptation in Athletes: A Systematic Review [J].
da Silva, Vanessa Pereira ;
de Oliveira, Natacha Alves ;
Silveira, Heitor ;
Tavares Mello, Roger Gomes ;
Deslandes, Andrea Camaz .
ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2015, 20 (02) :108-118
[8]  
Esco MR, 2014, J SPORT SCI MED, V13, P535
[9]   Heart rate variability stabilization in athletes: towards more convenient data acquisition [J].
Flatt, Andrew A. ;
Esco, Michael R. .
CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2016, 36 (05) :331-336
[10]   Validity of the ithlete™ Smart Phone Application for Determining Ultra-Short-Term Heart Rate Variability [J].
Flatt, Andrew A. ;
Esco, Michael R. .
JOURNAL OF HUMAN KINETICS, 2013, 39 (01) :85-92