Wearable force sensor with parallel structure for measurement of ground-reaction force

被引:42
作者
Liu, Tao [1 ]
Inoue, Yoshio [1 ]
Shibata, Kyoko [1 ]
机构
[1] Kochi Univ Technol, Dept Intelligent Mech Syst Engn, Kama City, Kochi 7828502, Japan
关键词
wearable sensor; load cell; finite element method; human dynamics; GAIT ANALYSIS; DESIGN; SYSTEM;
D O I
10.1016/j.measurement.2006.08.008
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper presents development of a wearable force sensor system for human dynamics analysis. Forces and moments are detected by combining responses from eight load cells fabricated on a parallel connection foundation. Finite element method was used for designing preliminary mechanical structures and simulating the mechanical stresses and strains in the load cells. Sensitivity of the load cells in the force sensor was increased by distributing strain gauges on the maximum strain positions. A smart electrical board consisting of signal conditioning circuits, A/D module and a micro-computer controller based communication module was built and integrated into the force sensor. The calibration experiments were performed using a force platform (EFP-S-2KNSA12) as a reference sensor, and in order to investigate interference errors of the sensor, preliminary characterization tests were implemented using a purposely developed characterization workstation. The sensor's abilities to measure ground-reaction forces with high precision and low interference error were demonstrated. (c) 2006 Elsevier Ltd. Ail rights reserved.
引用
收藏
页码:644 / 653
页数:10
相关论文
共 21 条
[1]   Evaluation of an ambulatory system for gait analysis in hip osteoarthritis and after total hip replacement [J].
Aminian, K ;
Trevisan, C ;
Najafi, B ;
Dejnabadi, H ;
Frigo, C ;
Pavan, E ;
Telonio, A ;
Cerati, F ;
Marinoni, EC ;
Robert, P ;
Leyvraz, PF .
GAIT & POSTURE, 2004, 20 (01) :102-107
[2]  
[Anonymous], STAT TECHNIQUES DATA
[3]   Design and fabrication of a hybrid silicon three-axial force sensor for biomechanical applications [J].
Beccai, L ;
Roccella, S ;
Arena, A ;
Valvo, F ;
Valdastri, P ;
Menciassi, A ;
Carrozza, MC ;
Dario, P .
SENSORS AND ACTUATORS A-PHYSICAL, 2005, 120 (02) :370-382
[4]   Direct measurement of ankle stiffness during quiet standing: implications for control modelling and clinical application [J].
Casadio, M ;
Morasso, PG ;
Sanguineti, V .
GAIT & POSTURE, 2005, 21 (04) :410-424
[5]   The six-component force sensor for measuring the loading of the feet in locomotion [J].
Chao, LP ;
Yin, CY .
MATERIALS & DESIGN, 1999, 20 (05) :237-244
[6]   Instrumented shoes for pathological gait assessment [J].
Faivre, A ;
Dahan, M ;
Parratte, B ;
Monnier, G .
MECHANICS RESEARCH COMMUNICATIONS, 2004, 31 (05) :627-632
[7]  
HARRIS GF, 1996, HUMAN MOTION ANAL, P12
[8]  
INOUE Y, 2003, JSME S HUM DYN, P57
[9]   Tracking people in three dimensions using a hierarchical model of dynamics [J].
Karaulova, IA ;
Hall, PM ;
Marshall, AD .
IMAGE AND VISION COMPUTING, 2002, 20 (9-10) :691-700
[10]   Gait analysis system for assessment of dynamic loading axis of the knee [J].
Kawakami, H ;
Sugano, N ;
Yonenobu, K ;
Yoshikawa, H ;
Ochi, T ;
Hattori, A ;
Suzuki, N .
GAIT & POSTURE, 2005, 21 (01) :125-130