On the importance of modeling balloon folding, pleating, and stent crimping: An FE study comparing experimental inflation tests

被引:31
作者
Geith, Markus A. [1 ,2 ,3 ]
Swidergal, Krzysztof [3 ]
Hochholdinger, Bernd [4 ]
Schratzenstaller, Thomas G. [3 ]
Wagner, Marcus [3 ]
Holzapfel, Gerhard A. [1 ,5 ]
机构
[1] Graz Univ Technol, Inst Biomech, Stremayrgasse 16-2, A-8010 Graz, Austria
[2] Kings Coll London, Dept Biomed Engn, London, England
[3] Ostbayer Tech Hsch, Fac Mech Engn, Regensburg, Germany
[4] DYNAmore Swiss GmbH, Zurich, Switzerland
[5] Norwegian Univ Sci & Technol, Dept Struct Engn, Trondheim, Norway
关键词
catheter; coronary; crimping; finite element; numerical; stent; SIROLIMUS-ELUTING STENTS; BARE-METAL STENTS; CORONARY STENTS; NEOINTIMAL PROLIFERATION; MECHANICAL-BEHAVIOR; NUMERICAL-ANALYSIS; EXPANSION; IMPLANTATION; RESTENOSIS; THROMBOSIS;
D O I
10.1002/cnm.3249
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Finite element (FE)-based studies of preoperative processes such as folding, pleating, and stent crimping with a comparison with experimental inflation tests are not yet available. Therefore, a novel workflow is presented in which residual stresses of balloon folding and pleating, as well as stent crimping, and the geometries of all contact partners were ultimately implemented in an FE code to simulate stent expansion by using an implicit solver. The numerical results demonstrate that the incorporation of residual stresses and strains experienced during the production step significantly increased the accuracy of the subsequent simulations, especially of the stent expansion model. During the preoperative processes, stresses inside the membrane and the stent material also reached a rather high level. Hence, there can be no presumption that balloon catheters or stents are undamaged before the actual surgery. The implementation of the realistic geometry, in particular the balloon tapers, and the blades of the process devices improved the simulation of the expansion mechanisms, such as dogboning, concave bending, or overexpansion of stent cells. This study shows that implicit solvers are able to precisely simulate the mentioned preoperative processes and the stent expansion procedure without a preceding manipulation of the simulation time or physical mass.
引用
收藏
页数:19
相关论文
共 57 条
[1]   MANAGEMENT OF RESTENOSIS WITHIN THE PALMAZ-SCHATZ CORONARY STENT (THE UNITED-STATES MULTICENTER EXPERIENCE) [J].
BAIM, DS ;
LEVINE, MJ ;
LEON, MB ;
LEVINE, S ;
ELLIS, SG ;
SCHATZ, RA .
AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (04) :364-366
[2]   Drug-Eluting or Bare-Metal Stents for Coronary Artery Disease [J].
Bonaa, K. H. ;
Mannsverk, J. ;
Wiseth, R. ;
Aaberge, L. ;
Myreng, Y. ;
Nygard, O. ;
Nilsen, D. W. ;
Klow, N. -E. ;
Uchto, M. ;
Trovik, T. ;
Bendz, B. ;
Stavnes, S. ;
Bjornerheim, R. ;
Larsen, A. -I. ;
Slette, M. ;
Steigen, T. ;
Jakobsen, O. J. ;
Bleie, O. ;
Fossum, E. ;
Hanssen, T. A. ;
Dahl-Eriksen, O. ;
Njolstad, I. ;
Rasmussen, K. ;
Wilsgaard, T. ;
Nordrehaug, J. E. .
NEW ENGLAND JOURNAL OF MEDICINE, 2016, 375 (13) :1242-1252
[3]   Numerical analysis of crimping and inflation process of balloon-expandable coronary stent using implicit solution [J].
Bukala, Jakub ;
Kwiatkowski, Piotr ;
Malachowski, Jerzy .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2017, 33 (12)
[4]   Numerical analysis of stent expansion process in coronary artery stenosis with the use of non-compliant balloon [J].
Bukala, Jakub ;
Kwiatkowski, Piotr ;
Malachowski, Jerzy .
BIOCYBERNETICS AND BIOMEDICAL ENGINEERING, 2016, 36 (01) :145-156
[5]   Realistic finite element-based stent design: The impact of balloon folding [J].
De Beule, Matthieu ;
Mortier, Peter ;
Carlier, Stphane G. ;
Verhegghe, Benedict ;
Van Impe, Rudy ;
Verdonck, Pascal .
JOURNAL OF BIOMECHANICS, 2008, 41 (02) :383-389
[6]   Sirolimus-eluting stent for treatment of complex in-stent restenosis - The first clinical experience [J].
Degertekin, M ;
Regar, E ;
Tanabe, K ;
Smits, PC ;
van der Giessen, WJ ;
Carlier, SG ;
de Feyter, P ;
Vos, J ;
Foley, DP ;
Ligthart, JMR ;
Popma, JJ ;
Serruys, PW .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (02) :184-189
[7]   BIOCOMPATIBILITY OF POLYMER-COATED OVERSIZED METALLIC STENTS IMPLANTED IN NORMAL PORCINE CORONARY-ARTERIES [J].
DESCHEERDER, IK ;
WILCZEK, KL ;
VERBEKEN, EV ;
VANDORPE, J ;
LAN, PN ;
SCHACHT, E ;
DEGEEST, H ;
PIESSENS, J .
ATHEROSCLEROSIS, 1995, 114 (01) :105-114
[8]   Mechanical behaviour modelling of balloon-expandable stents [J].
Dumoulin, C ;
Cochelin, B .
JOURNAL OF BIOMECHANICS, 2000, 33 (11) :1461-1470
[9]  
Early M, 2009, COMPUT METHOD BIOMEC, V12, P25, DOI [10.1080/10255840802136135, 10.1080/10255840903065043]
[10]   A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE [J].
FISCHMAN, DL ;
LEON, MB ;
BAIM, DS ;
SCHATZ, RA ;
SAVAGE, MP ;
PENN, I ;
DETRE, K ;
VELTRI, L ;
RICCI, D ;
NOBUYOSHI, M ;
CLEMAN, M ;
HEUSER, R ;
ALMOND, D ;
TEIRSTEIN, PS ;
FISH, RD ;
COLOMBO, A ;
BRINKER, J ;
MOSES, J ;
SHAKNOVICH, A ;
HIRSHFELD, J ;
BAILEY, S ;
ELLIS, S ;
RAKE, R ;
GOLDBERG, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :496-501