COMP Report: A survey of radiation safety regulations for medical imaging x-ray equipment in Canada

被引:5
作者
Bjarnason, Thorarin A. [1 ,2 ,3 ]
Rees, Robert [4 ]
Kainz, Judy [5 ]
Le, Lawrence H. [6 ,7 ]
Stewart, Errol E. [6 ,23 ]
Preston, Brent [8 ]
Elbakri, Idris [9 ,10 ,11 ]
Fife, Ingvar A. J. [9 ,10 ,11 ]
Lee, Ting-Yim [12 ,13 ,14 ]
Gagnon, I. Martin Benoit [15 ]
Arsenault, Clement [16 ]
Therrien, Pierre [17 ]
Kendall, Edward [18 ]
Tonkopi, Elena [19 ,20 ,21 ]
Cottreau, Michelle [22 ]
Aldrich, John E. [2 ]
机构
[1] Interior Hlth Author, Med Imaging, Kelowna, BC, Canada
[2] Univ British Columbia, Radiol, Vancouver, BC, Canada
[3] Univ British Columbia Okanagan, Phys, Kelowna, BC, Canada
[4] Yukon Workers Compensat Hlth & Safety Board, Occupat Hlth & Safety, Whitehorse, YT, Canada
[5] Workers Safety & Compensat Commiss Northwest Terr, Yellowknife, NT, Canada
[6] Alberta Hlth Serv, Diagnost Imaging, Edmonton, AB, Canada
[7] Univ Alberta, Radiol & Diagnost Imaging, Edmonton, AB, Canada
[8] Govt Saskatchewan, Radiat Safety Unit, Saskatoon, SK, Canada
[9] Canc Care Manitoba, Winnipeg, MB, Canada
[10] Univ Manitoba, Phys & Astron, Winnipeg, MB, Canada
[11] Univ Manitoba, Radiol, Winnipeg, MB, Canada
[12] St Josephs Hlth Care London, London, ON, Canada
[13] Lawson Res Inst, London, ON, Canada
[14] Univ Western Ontario, Robarts Res Inst, Med Imaging, Med Biophys,Oncol, London, ON, Canada
[15] Minist Sante & Serv Sociaux Quebec, Quebec City, PQ, Canada
[16] Hop Dr Georges L Dumont, Ctr Oncol Dr Leon Richard, Moncton, NB, Canada
[17] Horizon Hlth Network, Therapeut Phys, St John, NB, Canada
[18] Mem Univ, Fac Med, St John, NF, Canada
[19] Nova Scotia Hlth Author, Halifax, NS, Canada
[20] Dalhousie Univ, Diagnost Radiol, Halifax, NS, Canada
[21] Dalhousie Univ, Radiat Oncol, Halifax, NS, Canada
[22] Hlth PEI Diagnost Imaging, Charlottetown, PE, Canada
[23] Alberta Hlth Serv, Diagnost Imaging, Calgary, AB, Canada
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2020年 / 21卷 / 03期
关键词
diagnostic radiology; medical imaging; occupational dose; radiation safety; shielding;
D O I
10.1002/acm2.12708
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
X-ray regulations and room design methodology vary widely across Canada. The Canadian Organization of Medical Physicists (COMP) conducted a survey in 2016/2017 to provide a useful snapshot of existing variations in rules and methodologies for human patient medical imaging facilities. Some jurisdictions no longer have radiation safety regulatory requirements and COMP is concerned that lack of regulatory oversight might erode safe practices. Harmonized standards will facilitate oversight that will ensure continued attention is given to public safety and to control workplace exposure. COMP encourages all Canadian jurisdictions to adopt the dose limits and constraints outlined in Health Canada Safety Code 35 with the codicil that the design standards be updated to those outlined in NCRP 147 and BIR 2012.
引用
收藏
页码:10 / 19
页数:10
相关论文
共 50 条
  • [21] Radiation exposure of medical staff from interventional x-ray procedures: a multicentre study
    Haeusler, Uwe
    Czarwinski, Renate
    Brix, Gunnar
    EUROPEAN RADIOLOGY, 2009, 19 (08) : 2000 - 2008
  • [22] Status of Radiation Protection of Medical X-Ray Facilities in Greater Accra Region, Ghana
    Emi-Reynolds, Geoffrey
    Mensah, Cynthia Kaikor
    Gyekye, Prince Kwabena
    Amekudzie, Ann Etornam
    HEALTH PHYSICS, 2012, 102 (05): : S63 - S66
  • [23] Metal Halide Perovskites for Direct X-Ray Detection in Medical Imaging: To Higher Performance
    Fan, Jinyang
    Li, Wei
    Zhou, Quan
    Yang, Guo
    Tang, Pengfei
    He, Junhai
    Ma, Lin
    Zhang, Jianfei
    Xiao, Jiawen
    Yan, Zhengguang
    Li, Ang
    Han, Xiaodong
    ADVANCED FUNCTIONAL MATERIALS, 2024,
  • [24] Human thyroid specimen imaging by fluorescent x-ray computed tomography with synchrotron radiation
    Takeda, T
    Yu, QW
    Yashiro, T
    Yuasa, T
    Hasegawa, Y
    Itai, Y
    Akatsuka, T
    DEVELOPMENTS IN X-RAY TOMOGRAPHY II, 1999, 3772 : 258 - 267
  • [25] Development and characterization of a 3D GaAs X-ray detector for medical imaging
    d'Aillon, Eric Gros
    Avenel, Marie-Laure
    Farcage, Daniel
    Verger, Loick
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 727 : 126 - 130
  • [26] Scatter estimation and correction using time-of-flight and deconvolution in x-ray medical imaging
    Rossignol, Julien
    Belanger, Gabriel
    Fromont, Maelle
    Therrien, Audrey C.
    Fontaine, Rejean
    Berube-Lauziere, Yves
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (17)
  • [27] New amorphous-silicon image sensor for x-ray diagnostic medical imaging applications
    Weisfield, RL
    Hartney, MA
    Street, RA
    Apte, RB
    PHYSICS OF MEDICAL IMAGING, 1998, 3336 : 444 - 452
  • [28] Evaluation of a CMOS image detector for low cost and power medical X-ray imaging applications
    Smith, ST
    Bednarek, DR
    Wobschall, DC
    Jeong, MK
    Kim, HK
    Rudin, S
    MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 952 - 961
  • [29] A large area, multi-mode, flat panel medical X-ray imaging system
    Wright, MD
    Batts, M
    Boyce, S
    Colbeth, RE
    Fong, R
    Gray, K
    Harris, R
    Job, I
    Mollov, I
    Nepo, B
    Partain, LD
    Pavkovich, JM
    Seppi, EJ
    Shapiro, E
    Taie, N
    Webb, C
    Yu, J
    Zentai, GE
    IEEE-EMBS ASIA PACIFIC CONFERENCE ON BIOMEDICAL ENGINEERING - PROCEEDINGS, PTS 1 & 2, 2000, : 224 - 225
  • [30] Configurable real-time motion estimation for medical imaging: application to X-ray and ultrasound
    Abramov N.
    Fradkin M.
    Rouet L.
    Wischmann H.-A.
    Journal of Real-Time Image Processing, 2017, 13 (1) : 147 - 160