COMP Report: A survey of radiation safety regulations for medical imaging x-ray equipment in Canada

被引:5
作者
Bjarnason, Thorarin A. [1 ,2 ,3 ]
Rees, Robert [4 ]
Kainz, Judy [5 ]
Le, Lawrence H. [6 ,7 ]
Stewart, Errol E. [6 ,23 ]
Preston, Brent [8 ]
Elbakri, Idris [9 ,10 ,11 ]
Fife, Ingvar A. J. [9 ,10 ,11 ]
Lee, Ting-Yim [12 ,13 ,14 ]
Gagnon, I. Martin Benoit [15 ]
Arsenault, Clement [16 ]
Therrien, Pierre [17 ]
Kendall, Edward [18 ]
Tonkopi, Elena [19 ,20 ,21 ]
Cottreau, Michelle [22 ]
Aldrich, John E. [2 ]
机构
[1] Interior Hlth Author, Med Imaging, Kelowna, BC, Canada
[2] Univ British Columbia, Radiol, Vancouver, BC, Canada
[3] Univ British Columbia Okanagan, Phys, Kelowna, BC, Canada
[4] Yukon Workers Compensat Hlth & Safety Board, Occupat Hlth & Safety, Whitehorse, YT, Canada
[5] Workers Safety & Compensat Commiss Northwest Terr, Yellowknife, NT, Canada
[6] Alberta Hlth Serv, Diagnost Imaging, Edmonton, AB, Canada
[7] Univ Alberta, Radiol & Diagnost Imaging, Edmonton, AB, Canada
[8] Govt Saskatchewan, Radiat Safety Unit, Saskatoon, SK, Canada
[9] Canc Care Manitoba, Winnipeg, MB, Canada
[10] Univ Manitoba, Phys & Astron, Winnipeg, MB, Canada
[11] Univ Manitoba, Radiol, Winnipeg, MB, Canada
[12] St Josephs Hlth Care London, London, ON, Canada
[13] Lawson Res Inst, London, ON, Canada
[14] Univ Western Ontario, Robarts Res Inst, Med Imaging, Med Biophys,Oncol, London, ON, Canada
[15] Minist Sante & Serv Sociaux Quebec, Quebec City, PQ, Canada
[16] Hop Dr Georges L Dumont, Ctr Oncol Dr Leon Richard, Moncton, NB, Canada
[17] Horizon Hlth Network, Therapeut Phys, St John, NB, Canada
[18] Mem Univ, Fac Med, St John, NF, Canada
[19] Nova Scotia Hlth Author, Halifax, NS, Canada
[20] Dalhousie Univ, Diagnost Radiol, Halifax, NS, Canada
[21] Dalhousie Univ, Radiat Oncol, Halifax, NS, Canada
[22] Hlth PEI Diagnost Imaging, Charlottetown, PE, Canada
[23] Alberta Hlth Serv, Diagnost Imaging, Calgary, AB, Canada
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2020年 / 21卷 / 03期
关键词
diagnostic radiology; medical imaging; occupational dose; radiation safety; shielding;
D O I
10.1002/acm2.12708
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
X-ray regulations and room design methodology vary widely across Canada. The Canadian Organization of Medical Physicists (COMP) conducted a survey in 2016/2017 to provide a useful snapshot of existing variations in rules and methodologies for human patient medical imaging facilities. Some jurisdictions no longer have radiation safety regulatory requirements and COMP is concerned that lack of regulatory oversight might erode safe practices. Harmonized standards will facilitate oversight that will ensure continued attention is given to public safety and to control workplace exposure. COMP encourages all Canadian jurisdictions to adopt the dose limits and constraints outlined in Health Canada Safety Code 35 with the codicil that the design standards be updated to those outlined in NCRP 147 and BIR 2012.
引用
收藏
页码:10 / 19
页数:10
相关论文
共 50 条
  • [1] Fundamentals of X-ray imaging and radiation safety
    Bashore, T
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2001, 54 (01) : 126 - 135
  • [2] Perspectives of medical X-ray imaging
    Freudenberger, J
    Hell, E
    Knüpfer, W
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 466 (01) : 99 - 104
  • [3] X-ray medical imaging - A centennial perspective
    Sprawls, P
    PHYSICA MEDICA, 1997, 13 : 193 - 196
  • [4] A new X-ray source for medical imaging and radiotherapy research: Synchrotron radiation.
    LeBas, JF
    Charvet, AM
    Elleaume, H
    Bertrand, B
    Esteve, F
    Spanne, P
    Suortti, P
    BULLETIN DU CANCER, 1995, 82 : S544 - S548
  • [5] Synchrotron X-ray Radiation (SXR) in Medical Imaging: Current Status and Future Prospects
    Tamal, Mahbubunnabi
    Althobaiti, Murad
    Alomari, Abdul-Hakeem
    Dipty, Sumaiya Tabassum
    Suha, Khadiza Tun
    Al-Hashim, Maryam
    APPLIED SCIENCES-BASEL, 2022, 12 (08):
  • [6] Radiation safety of patients during x-ray examination
    Voronin K.V.
    Smerdova L.A.
    Biomedical Engineering, 1998, 32 (3) : 169 - 173
  • [7] Improved X-Ray Safety, Quality Control, and Resource Management in Medical Imaging Using QATrack
    Buckley, Lesley
    Heddon, Gary
    Byrne, Ian
    Angers, Crystal
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2020, 51 (01) : 22 - 28
  • [8] Review of medical imaging with emphasis on X-ray detectors
    Hoheisel, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 563 (01) : 215 - 224
  • [9] Development of X-Ray Talbot-Lau Interferometer with a Practical X-Ray Tube for Medical Imaging
    Makifuchi, Chiho
    Kido, Kazuhiro
    Kiyohara, Junko
    Ito, Tsukasa
    Nagatsuka, Sumiya
    Momose, Atsushi
    INTERNATIONAL CONFERENCE ON ADVANCED PHASE MEASUREMENT METHODS IN OPTICS AN IMAGING, 2010, 1236 : 203 - +
  • [10] Modern requirements for radiation safety of x-ray diagnostic rooms
    Blinov N.N.
    Kozlovskii E.B.
    Biomedical Engineering, 2008, 42 (5) : 247 - 248