Intraoperative biomechanical assessment of lumbar spinal instability: Validation of radiographic parameters indicating anterior column support in lumbar spinal fusion

被引:55
作者
Kanayama, M [1 ]
Hashimoto, T [1 ]
Shigenobu, K [1 ]
Oha, F [1 ]
Ishida, T [1 ]
Yamane, S [1 ]
机构
[1] Hakodate Cent Gen Hosp, Dept Orthopaed Surg, Hakodate, Hokkaido 0408585, Japan
关键词
lumbar spinal instability; biomechanics; radiographic assessment; anterior column support; intraoperative measurement;
D O I
10.1097/01.BRS.0000085357.24025.27
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Lumbar spinal instability was evaluated using radiographic parameters and intraoperative biomechanical measurement. Objectives. To validate a conventional radiographic assessment using an intraoperative biomechanical measurement and to determine the radiographic parameters indicating anterior column support in lumbar spinal fusion. Background. Posterior lumbar interbody fusion is gaining acceptance in the treatment of degenerative spondylolisthesis, whereas posterolateral fusion alone may result in good clinical outcomes. A quantitative biomechanical assessment of spinal instability is essential to determine the optimal method of spinal arthrodesis. Materials and Methods. Nineteen cases with symptomatic degenerative spondylolisthesis were included in this study. All were candidates for pedicle-screw instrumented lumbar arthrodesis. A total of five L3-L4 segments and seventeen L4-L5 segments were investigated. Radiographic assessment included disc angle, range of motion ( ROM), percent of slip, and percent of posterior disc height. Distraction stiffness of the operative segment was measured intraoperatively using a strain-gauged spreader. Results. Disc angle in flexion and ROM were highly correlated to distraction stiffness. Severity of slip, disc space narrowing, and facet tropism did not influence the distraction stiffness. The cases with segmental kyphosis in flexion had significantly lower distraction stiffness than those showing segmental lordosis in flexion. Conclusions. Disc angle in flexion and ROM were the most prognostic parameters of lumbar distraction instability. Although the option of spinal arthrodesis method should be determined based on both clinical manifestation and imaging studies, the current study demonstrated that providing of anterior column support is biomechanically reasonable for degenerative spondylolisthesis with segmental kyphosis in flexion.
引用
收藏
页码:2368 / 2372
页数:5
相关论文
共 22 条
[1]   Mechanics of the external fixation test in the lumbar spine - A roentgen stereophotogrammetric analysis [J].
Axelsson, P ;
Johnsson, R ;
Stromqvist, B .
SPINE, 1996, 21 (03) :330-333
[2]   Lumbar interbody fusion using the Brantigan I/F Cage for posterior lumbar interbody fusion and the variable pedicle screw placement system - Two-year results from a Food and Drug Administration Investigational Device Exemption Clinical Trial [J].
Brantigan, JW ;
Steffee, AD ;
Lewis, ML ;
Quinn, LM ;
Persenaire, JM .
SPINE, 2000, 25 (11) :1437-1446
[3]   THE ROLE OF FUSION AND INSTRUMENTATION IN THE TREATMENT OF DEGENERATIVE SPONDYLOLISTHESIS WITH SPINAL STENOSIS [J].
BRIDWELL, KH ;
SEDGEWICK, TA ;
OBRIEN, MF ;
LENKE, LG ;
BALDUS, C .
JOURNAL OF SPINAL DISORDERS, 1993, 6 (06) :461-472
[5]  
Ebara S, 1992, SPINE, V17, P44
[6]   THE ROLE OF EXTERNAL SPINAL SKELETAL FIXATION IN THE ASSESSMENT OF LOW-BACK DISORDERS [J].
ESSES, SI ;
BOTSFORD, DJ ;
KOSTUIK, JP .
SPINE, 1989, 14 (06) :594-601
[7]   ROENTGENOGRAPHIC AND BIOMECHANICAL ANALYSIS OF LUMBAR FUSIONS - A CANINE MODEL [J].
GURR, KR ;
MCAFEE, PC ;
WARDEN, KE ;
SHIH, CM .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1989, 7 (06) :838-848
[8]   INSTANTANEOUS AXIS OF ROTATION AS A FUNCTION OF THE 3 COLUMNS OF THE SPINE [J].
HAHER, TR ;
OBRIEN, M ;
FELMLY, WT ;
WELIN, D ;
PERRIER, G ;
CHOUEKA, J ;
DEVLIN, V ;
VASSILIOU, A ;
CHOW, G .
SPINE, 1992, 17 (06) :S149-S154
[9]  
HAHER TR, 1994, SPINE, V19, P2667, DOI 10.1097/00007632-199412010-00012
[10]   Clinical results of single-level posterior lumbar interbody fusion using the Brantigan I/F carbon cage filled with a mixture of local morselized bone and bioactive ceramic granules [J].
Hashimoto, T ;
Shigenobu, K ;
Kanayama, M ;
Harada, M ;
Oha, F ;
Ohkoshi, Y ;
Tada, H ;
Yamamoto, K ;
Yamane, S .
SPINE, 2002, 27 (03) :258-262