Impact of Tear Location on Hemodynamics in a Type B Aortic Dissection investigated with Computational Fluid Dynamics

被引:20
作者
Karmonik, Christof [1 ]
Bismuth, Jean [2 ]
Redel, Thomas [2 ]
Anaya-Ayala, Javier E. [2 ]
Davies, Mark G. [2 ]
Shah, Dipan J. [2 ]
Lumsden, Alan B. [2 ]
机构
[1] Methodist Hosp, Neurol Inst, 6535 Fannin, Houston, TX 77030 USA
[2] Methodist DeBakey Heart & Vascular ctr, Houston, TX 77030 USA
来源
2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC) | 2010年
关键词
BLOOD-FLOW; MODEL;
D O I
10.1109/IEMBS.2010.5627193
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Stanford type B aortic dissections (TB-AD), which split the descending aorta in a true and false lumen, have better in-hospital survival than type A dissections affecting the ascending aorta. However, short-term and long-term prognosis for the individual patient remains challenging, with one in four patients not surviving after 3 years. Towards a better understanding of the influence of tear location on TB-AD hemodynamics, we performed computational fluid dynamics (CFD) with aortic geometry extracted from magnetic resonance angiographic (MRA) images and inflow conditions modeled using the aortic flow waveform measured with 2D phase contrast magnetic resonance imaging (2D pcMRI). Three configurations were investigated. Configuration 1 had both entrance and re-entrance tear (as imaged), in configuration 2 the re-entrance tear was virtually occluded to simulate disease progression (thrombus formation) and in configuration 3, the entrance tear was virtually occluded, simulating endovascular treatment (EVAR) i.e. placing a stent-graft to eliminate inflow into the false lumen. For incorporation of the simulation results into the clinical workflow, a Siemens Leonardo software plugin prototype was developed to visualize and quantify hemodynamic parameters as 4D (3D plus time) volumes. Pressure in the true lumen for all three configurations was similar and varied about 3.4% (largest variation between configuration 1 and 3). Pressure in the false lumen increased by 7.4% for configuration 2 compared to configuration 1 and dropped by 97% for configuration 3 compared to configuration 1. Pressure difference curves (true lumen value subtracted from false lumen value) showed similar behavior for configuration 1 and 2 with largest differences occurring during systole. For configuration 3, largest decrease in pressure difference occurred during systole. Higher pressure in the false lumen compared to the true lumen was found at end systole, indicating reversal of sign of pressure difference in configuration 3 (virtually treated TB-AD by EVAR). Velocity patterns did not show pronounced differences between configuration 1 and 2 but revealed reduced flow in the false lumen for configuration 3.
引用
收藏
页码:3138 / 3141
页数:4
相关论文
共 11 条
[1]   The International Registry of Acute Aortic Dissection (IRAD) - New insights into an old disease [J].
Hagan, PG ;
Nienaber, CA ;
Isselbacher, EM ;
Bruckman, D ;
Karavite, DJ ;
Russman, PL ;
Evangelista, A ;
Fattori, R ;
Suzuki, T ;
Oh, JK ;
Moore, AG ;
Malouf, JF ;
Pape, LA ;
Gaca, C ;
Sechtem, U ;
Lenferink, S ;
Deutsch, HJ ;
Diedrichs, H ;
Robles, JMY ;
Llovet, A ;
Gilon, D ;
Das, SK ;
Armstrong, WF ;
Deeb, GM ;
Eagle, KA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2000, 283 (07) :897-903
[2]   Blood flow in cerebral aneurysms: Comparison of phase contrast magnetic resonance and computational fluid dynamics - Preliminary experience [J].
Karmonik, C. ;
Klucznik, R. ;
Benndorf, G. .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2008, 180 (03) :209-215
[3]  
KARMONIK C., 2009, ROFO 1026
[4]  
Karmonik Christof, 2008, Technol Health Care, V16, P343
[5]  
Karmonik Christof, 2008, Technol Health Care, V16, P119
[6]  
KUMAR BVR, 1995, COMPUT BIOL MED, V25, P1, DOI 10.1016/0010-4825(95)98881-D
[7]  
Leuprecht A, 2002, BIORHEOLOGY, V39, P425
[8]   PROSPECTS FOR COMPUTATIONAL FLUID-MECHANICS [J].
PATTERSON, GS .
ANNUAL REVIEW OF FLUID MECHANICS, 1978, 10 :289-300
[9]  
SPIEGEL M, 2009, EMBC 2009 ANN INT C, P2787
[10]  
Steinman David A., 2004, Current Drug Targets - Cardiovascular & Haematological Disorders, V4, P183, DOI 10.2174/1568006043336302