Sensitivity enhancement in laser ablation ICP-MS using small amounts of hydrogen in the carrier gas

被引:121
作者
Guillong, Marcel [1 ]
Heinrich, Christoph A. [1 ]
机构
[1] ETH, Dept Earth Sci, Isotope Geochem & Min Resources, CH-8092 Zurich, Switzerland
关键词
D O I
10.1039/b709489b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The addition of 4 - 9 ml min(-1) of hydrogen to the helium carrier gas flow in 193 nm excimer laser ablation increases the sensitivity for most of 47 investigated elements by a factor of 2 - 4. The sensitivity enhancement for some elements, including beryllium, phosphorus, arsenic, platinum and gold, is even 5 - 7 fold. This effect can be explained by a higher electron temperature in the plasma. A correlation exists between the enhancement factor and the 1st ionization energy. Limits of detection are improved for all elements except those with hydrogen based polyatomic interferences, such as silicon, potassium, calcium and selenium, thus opening up new applications in LA- ICP- MS. A similar but weaker effect was found for the addition of methane; almost no sensitivity enhancement was found for nitrogen addition.
引用
收藏
页码:1488 / 1494
页数:7
相关论文
共 36 条
[1]   High-speed digital photographic study of an inductively coupled plasma during laser ablation: comparison of dried solution aerosols from a microconcentric nebulizer and solid particles from laser ablation [J].
Aeschliman, DB ;
Bajic, SJ ;
Baldwin, DP ;
Houk, RS .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (09) :1008-1014
[2]   INVESTIGATIONS ON MIXED-GAS PLASMAS PRODUCED BY ADDING NITROGEN TO THE PLASMA GAS IN ICP-MS [J].
BEAUCHEMIN, D ;
CRAIG, JM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1991, 46 (05) :603-614
[3]   TEMPERATURE AND CONCENTRATION MEASUREMENTS OF MOLECULAR-HYDROGEN IN A FILAMENTARY DISCHARGE BY COHERENT ANTI-STOKES-RAMAN SPECTROSCOPY (CARS) [J].
BORNEMANN, T ;
KORNAS, V ;
SCHULZVONDERGATHEN, V ;
DOBELE, HF .
APPLIED PHYSICS B-PHOTOPHYSICS AND LASER CHEMISTRY, 1990, 51 (05) :307-313
[4]   FEASIBILITY OF IMPROVEMENT IN ANALYTICAL PERFORMANCE IN LASER-ABLATION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY (LA-ICP-MS) BY ADDITION OF NITROGEN TO THE ARGON PLASMA [J].
DURRANT, SF .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 349 (10-11) :768-771
[5]   ALTERNATIVES TO ALL-ARGON PLASMAS IN INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY (ICP-MS) - AN OVERVIEW [J].
DURRANT, SF .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 347 (10-11) :389-392
[6]   SLURRY ATOMIZATION USING HYDROGEN-MODIFIED INDUCTIVELY COUPLED PLASMAS [J].
EBDON, L ;
GOODALL, P .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (07) :1111-1116
[7]   Deposition and element fractionation processes during atmospheric pressure laser sampling for analysis by ICP-MS [J].
Eggins, SM ;
Kinsley, LPJ ;
Shelley, JMG .
APPLIED SURFACE SCIENCE, 1998, 127 :278-286
[8]  
EHRISMANN F, 2007, THESIS DEP EARTH SCI
[9]   A comparison of 266 nm, 213 nm and 193 nm produced from a single solid state Nd:YAG laser for laser ablation ICP-MS [J].
Guillong, M ;
Horn, I ;
Günther, D .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (10) :1224-1230
[10]   Effect of particle size distribution on ICP-induced elemental fractionation in laser ablation-inductively coupled plasma-mass spectrometry [J].
Guillong, M ;
Günther, D .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (08) :831-837