Magnetization-Prepared IDEAL bSSFP: A Flow-Independent Technique for Noncontrast-Enhanced Peripheral Angiography

被引:23
作者
Cukur, Tolga [1 ]
Shimakawa, Ann [2 ]
Yu, Huanzhou [2 ]
Hargreaves, Brian A. [3 ]
Hu, Bob S. [4 ]
Nishimura, Dwight G. [5 ]
Brittain, Jean H. [6 ]
机构
[1] Univ Calif Berkeley, Helen Wills Neurosci Inst, Berkeley, CA 94720 USA
[2] GE Healthcare, MR Global Appl Sci Lab, Menlo Pk, CA USA
[3] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[4] Palo Alto Med Fdn, Palo Alto, CA USA
[5] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[6] GE Healthcare, MR Global Appl Sci Lab, Madison, WI USA
基金
美国国家卫生研究院;
关键词
peripheral angiography; MR angiography; noncontrast enhanced; flow-independent; IDEAL; SSFP; STATE FREE PRECESSION; WATER-FAT SEPARATION; FAST SPIN-ECHO; MR-ANGIOGRAPHY; BALANCED SSFP; CONTRAST; RESONANCE; ACQUISITION; SEQUENCES;
D O I
10.1002/jmri.22479
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To propose a new noncontrast-enhanced flow-independent angiography sequence based on balanced steady-state free precession (bSSFP) that produces reliable vessel contrast despite the reduced blood flow in the extremities. Materials and Methods: The proposed technique addresses a variety of factors that can compromise the exam success including insufficient background suppression, field inhomogeneity, and large volumetric coverage requirements. A bSSFP sequence yields reduced signal from venous blood when long repetition times are used. Complex-sum bSSFP acquisitions decrease the sensitivity to field inhomogeneity but retain phase information, so that data can be processed with the Iterative Decomposition of Water and Fat with Echo Asymmetry and Least-Squares Estimation (IDEAL) method for robust fat suppression. Meanwhile, frequent magnetization preparation coupled with parallel imaging reduces the muscle and long-T(1) fluid signals without compromising scan efficiency. Results: In vivo flow-independent peripheral angiograms with reliable background suppression and high spatial resolution are produced. Comparisons with phase-sensitive bSSFP angiograms (that yield out-of-phase fat and water signals, and exploit this phase difference to suppress fat) demonstrate enhanced vessel depiction with the proposed technique due to reduced partial-volume effects and improved venous suppression. Conclusion: Magnetization-prepared complex-sum bSSFP with IDEAL fat/water separation can create reliable flow-independent angiographic contrast in the lower extremities.
引用
收藏
页码:931 / 939
页数:9
相关论文
共 43 条
[1]  
[Anonymous], 2004, HDB MRI PULSE SEQUEN, DOI 10.1016/B978-0-12-092861-3.X5000-6
[2]   MR FLOW IMAGING BY VELOCITY-COMPENSATED UNCOMPENSATED DIFFERENCE IMAGES [J].
AXEL, L ;
MORTON, D .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (01) :31-34
[3]  
BANGERTER NK, 2004, P 12 ANN M ISMRM KYO
[4]   On the origin of apparent low tissue signals in balanced SSFD [J].
Bieri, O. ;
Scheffler, K. .
MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (05) :1067-1074
[5]   Comparison of reconstruction accuracy and efficiency among autocalibrating data-driven parallel imaging methods [J].
Brau, Anja C. S. ;
Beatty, Philip J. ;
Skare, Stefan ;
Bammer, Roland .
MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (02) :382-395
[6]  
Brittain J., 2004, P 12 ANN M ISMRM KYO
[7]   Three-dimensional flow-independent peripheral angiography [J].
Brittain, JH ;
Olcott, EW ;
Szuba, A ;
Gold, GE ;
Wright, GA ;
Irarrazaval, P ;
Nishimura, DG .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (03) :343-354
[8]  
BRITTAIN JH, 2003, P 11 ANN M ISMRM TOR
[9]  
BRITTAIN JH, 2005, P 13 ANN M ISMRM MIA
[10]   STEADY-STATE FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE [J].
CARR, HY .
PHYSICAL REVIEW, 1958, 112 (05) :1693-1701