Impulse Response Characterization of Breast Tomosynthesis Reconstruction with Parallel Imaging Configurations

被引:2
作者
Balla, Apuroop [1 ]
Zhou, Weihua [1 ]
Chen, Ying [1 ]
机构
[1] So Illinois Univ, Dept Elect & Comp Engn, Carbondale, IL 62901 USA
来源
MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING | 2010年 / 7622卷
关键词
mammography; tomosynthesis; shift-and-add (SAA); back projection (BP); filtered back projection (FBP); impulse response (IR); DIGITAL MAMMOGRAPHY; FILTERED BACKPROJECTION; ALGORITHMS; MITS;
D O I
10.1117/12.844320
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Early detection, diagnosis, and suitable treatment are known to significantly improve the chance of survival for breast cancer (BC) patients. To date, the most cost effective method for screening and early detection is mammography, which is also the tool that has demonstrated its ability to reduce BC mortality. Tomosynthesis is an emerging technology that offers an alternative to conventional two-dimensional mammography. Tomosynthesis produces three-dimensional (volumetric) images of the breast that may be superior to planar imaging due to improved visualization. In this paper we examined the effect of varying the number of projections (N) and total view angle (VA) on the shift-and-add (SAA), back projection (BP) and filtered back projection (FBP) image reconstruction response characterized by impulse response (IR) simulations. IR data were generated by simulating the projection images of a very thin wire, using various combinations of VA and N. Results suggested that BP and FBP performed better for in-plane performance than that of SAA. With bigger number of projection images, the investigated reconstruction algorithms performed the best by obtaining sharper in-focus IR with simulated parallel imaging configurations.
引用
收藏
页数:8
相关论文
共 33 条
[1]  
American Cancer Society, Breast Cancer Facts & Figures 2022-2024
[2]  
Bassett L.W., 2005, Diagnosis of Diseases of the Breast, V2 nd
[3]   Digital breast tomosynthesis using an amorphous selenium flat panel detector [J].
Bissonnette, M ;
Hansroul, M ;
Masson, E ;
Savard, S ;
Cadieux, S ;
Warmoes, P ;
Gravel, D ;
Agopyan, J ;
Polischuk, B ;
Haerer, W ;
Mertelmeier, T ;
Lo, JY ;
Chen, Y ;
Dobbins, JT ;
Jesneck, JL ;
Singh, S .
Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 :529-540
[4]   Impulse response analysis for several digital tomosynthesis mammography reconstruction algorithms [J].
Chen, Y ;
Lo, JY ;
Dobbins, JT .
Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 :541-549
[5]  
Chen Y., 2007, THESIS DUKE U
[6]   Importance of point-by-point back projection correction for isocentric motion in digital breast tomosynthesis: Relevance to morphology of structures such as microcalcifications [J].
Chen, Ying ;
Lo, Joseph Y. ;
Dobbins, James T., III .
MEDICAL PHYSICS, 2007, 34 (10) :3885-3892
[7]   Gaussian frequency blending algorithm with Matrix Inversion Tomosynthesis (MITS) and Filtered Back Projection (FBP) for better digital breast tomosynthesis reconstruction [J].
Chen, Ying ;
Lo, Joseph Y. ;
Baker, Jay A. ;
Dobbins, James T., III .
MEDICAL IMAGING 2006: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2006, 6142
[8]  
Cherney T, 1999, WMJ, V98, P47
[9]  
Dobbins III James T., 1990, US Patent, Patent No. [US4903204 A, 4903204]
[10]   Digital x-ray tomosynthesis: current state of the art and clinical potential [J].
Dobbins, JT ;
Godfrey, DJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (19) :R65-R106