Real-Time Three-Dimensional Transesophageal Echocardiography Is Useful for Percutaneous Closure of Multiple Secundum Atrial Septal Defects

被引:0
|
作者
Zhang, Chun [1 ]
Li, Zhian [1 ]
Xu, Jin [1 ]
机构
[1] Capital Med Univ, Beijing Anzhen Hosp, Dept Ultrasound, Beijing 100029, Peoples R China
关键词
Multiple atrial septal defects; transesophageal echocardiography; transcatheter closure; TRANSCATHETER CLOSURE; OCCLUDER; EXPERIENCE; IMMEDIATE;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: The purpose of this study was to investigate the clinical value of real-time three-dimensional transesophageal echocardiography (RT-3D-TEE) for percutaneous transcatheter closure of multiple secundum atrial septal defects (ASDs) using a Chinese domestic occluder device. Methods: From July 2008 to September 2011, 37 patients (mean age 28.4 +/- 9.7 years; 24 females) with multiple secundum ASDs underwent percutaneous transcatheter closure in our institution with custom-made occluder devices. RT-30-TEE was used to clarify the diagnosis and to help determine the operation scheme before the procedure, for real-time monitoring and guiding the operation during the procedure, and for evaluating the result shortly after the procedure. Results: The custom-made atrial septal occluders were successfully implanted in 36 patients under RT-3D-TEE guidance. Twenty-seven patients were implanted with two devices and 9 patients with a single device. In two patients where the distance between the two defects was less than 7 mm (5.5 mm and 6 mm), double occluder devices were also successfully implanted. One patient underwent surgery for the complication of unstable occluder and increased residual shunt after closure. No other severe complications were observed. Conclusions: RT-3D-TEE provides reliable diagnostic evidence of multiple ASDs and can help the clinician to select an appropriate operation scheme according to the number and morphology of multiple defects prior to percutaneous transcatheter closure. It also allows for proper positioning of the devices during the procedure and provides an effective means of evaluating the success of the procedure. For two devices to be implanted simultaneously in multiple ASDs, the usual requirement for the distance between the two defects may differ between our domestically made devices and the Amplatzer occluder.
引用
收藏
页码:486 / 491
页数:6
相关论文
共 50 条
  • [41] Transcatheter closure of multiple atrial septal defects - Initial results and value of two- and three-dimensional transoesophageal echocardiography
    Cao, QL
    Radtke, W
    Berger, F
    Zhu, W
    Hijazi, ZM
    EUROPEAN HEART JOURNAL, 2000, 21 (11) : 941 - 947
  • [42] Mid-term Outcomes of the Helex Septal Occluder for Percutaneous Closure of Secundum Atrial Septal Defects
    Correa, Rafael
    Zahn, Evan
    Khan, Danyal
    CONGENITAL HEART DISEASE, 2013, 8 (05) : 428 - 433
  • [43] Percutaneous closure of multiple atrial septal defects with three amplatzer septal occluder devices
    Lander, SR
    Phillips, S
    Vallabhan, RC
    Grayburn, PA
    Anwar, A
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 62 (04) : 526 - 529
  • [44] Complex Atrial Septal Defect: Percutaneous Repair Guided by Three-Dimensional Echocardiography
    Georgakis, Alexander
    Radtke, Wolfgang A. K.
    Lopez, Christian
    Fiss, David
    Moser, Cathy
    VanDecker, William
    O'Murchu, Brian
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2010, 27 (05): : 590 - 593
  • [45] Clinical Application of Three-dimensional Transesophageal Echocardiography in the Diagnosis of Atrial Septal Defect
    郑俐慧
    李治安
    王新房
    胡纲
    杨娅
    刘俐
    同济医科大学学报(外文版), 1996, (03) : 183 - 185
  • [46] Incremental Value of Live/Real Time Three-Dimensional over Two-Dimensional Transesophageal Echocardiography in the Assessment of Atrial Septal Pouch
    Elsayed, Mahmoud
    Hsiung, Ming C.
    Meggo-Quiroz, L. David
    Elguindy, Mostafa
    Uygur, Begum
    Tandon, Rohit
    Guvenc, Tolga
    Keser, Nurgul
    Vural, Mustafa G.
    Bulur, Serkan
    Chahwala, Jugal R.
    Abtahi, Firoozeh
    Nanda, Navin C.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2015, 32 (12): : 1858 - 1867
  • [47] Measurement of the aortic annulus size by real-time three-dimensional transesophageal echocardiography
    Janosi, Rolf Alexander
    Kahlert, Philipp
    Plicht, Bjoern
    Wendt, Daniel
    Eggebrecht, Holger
    Erbel, Raimund
    Buck, Thomas
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2011, 20 (02) : 85 - 94
  • [48] Evaluation of the left atrial appendage by real time three-dimensional transesophageal echocardiography online
    Zhang, Juan
    Cui, Cun-Ying
    Huang, Dan-Qing
    Liu, Yuan-Yuan
    Qin, Yun-Yun
    Zhang, Lian-Zhong
    Liu, Lin
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2018, 35 (07): : 991 - 998
  • [49] Clinical value of stereoscopic three-dimensional echocardiography in assessment of atrial septal defects: Feasibility and efficiency
    Wang, Jing
    Wang, Xinfang
    Xie, Mingxing
    He, Lin
    Lv, Qing
    Wang, Lei
    JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2009, 29 (06) : 791 - 794
  • [50] Incremental value of transesophageal echocardiography in the evaluation of patients before percutaneous closure of atrial septal defects Reply
    Chen, Qiang
    Cao, Hua
    Zhang, Gui-Can
    Chen, Liang-Wan
    Lu, Heng
    Yu, Ling-Li
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2019, 21 (03) : 177 - 177