Theoretical investigation of solar desalination with solar still having phase change material and connected to a solar collector

被引:78
作者
Abu-Arabi, Mousa [1 ,2 ]
Al-harahsheh, Mohammad [1 ]
Mousa, Hasan [1 ,3 ]
Alzghoul, Zobaidah [1 ]
机构
[1] Jordan Univ Sci & Technol, Dept Chem Engn, Irbid 22110, Jordan
[2] Kuwait Univ, Fac Engn & Petr, Dept Chem Engn, POB 5969, Safat 13060, Kuwait
[3] Sultan Qaboos Univ, Dept Petr & Chem Engn, POB 33, Muscat 123, Oman
关键词
Solar still; Phase change material; Sodium thiosulfate pentahydrate; Solar collector; Productivity; Theoretical modeling; THERMAL-ENERGY STORAGE; FLAT-PLATE COLLECTOR; WATER PRODUCTION; PRODUCTIVITY; PERFORMANCE; SINGLE; TECHNOLOGIES; SYSTEM; COVER; PCM;
D O I
10.1016/j.desal.2018.09.020
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A theoretical model is developed in this work to simulate a solar still connected to an external solar collector and incorporating Sodium Thiosulfate Pentahydrate as phase change material (PCM). Excellent agreement is obtained between the theoretical and experimental results for the unit productivity of fresh water and the basin water temperature profile. Sodium thiosulfate pentahydrate worked well as PCM to supply energy during night time for continuous water production and has improved the overall productivity. Incorporating large PCM mass in the system reduced the productivity; increasing the ratio of PCM mass to water mass from 10 to 100% reduced the productivity by up to 30%. While, incorporating large PCM mass in the system has kept the basin water temperature higher for longer time. This is useful if the unit is to be used for supplying potable water and hot water mainly after sunset and for heating purposes especially in cold places. Reducing the overall heat transfer coefficient from 10.4 to 2.6 W/m(2).K can increase the productivity by > 100%. The cooling water through the glass cover can have significant effect (37% increase) on the unit productivity of fresh water if its flow rate is increased from 0.01 to 0.1 kg/s.
引用
收藏
页码:60 / 68
页数:9
相关论文
共 31 条
[1]   Modeling and performance analysis of a solar desalination unit with double-glass cover cooling [J].
Abu-Arabi, M ;
Zurigat, Y ;
Al-Hinai, H ;
Al-Hiddabi, S .
DESALINATION, 2002, 143 (02) :173-182
[2]   Enhancing the solar still using immersion type water heater productivity and the effect of external cooling fan in winter1 [J].
Ahmed Z. Al-Garni .
Applied Solar Energy, 2012, 48 (3) :193-200
[3]   Solar desalination using solar still enhanced by external solar collector and PCM [J].
Al-harahsheh, Mohammad ;
Abu-Arabi, Mousa ;
Mousa, Hasan ;
Alzghoul, Zobaidah .
APPLIED THERMAL ENGINEERING, 2018, 128 :1030-1040
[4]   The effect of coupling a flat-plate collector on the solar still productivity [J].
Badran, OO ;
Al-Tahaineh, HA .
DESALINATION, 2005, 183 (1-3) :137-142
[5]   Enhancement of solar thermal energy storage performance using sodium thiosulfate pentahydrate of a conventional solar water-heating system [J].
Canbazoglu, S ;
Sahinaslan, A ;
Ekmekyapar, A ;
Aksoy, IG ;
Akarsu, F .
ENERGY AND BUILDINGS, 2005, 37 (03) :235-242
[6]   Experimental study on the air velocity effect on the efficiency and fresh water production in a forced convective double slope solar still [J].
Castillo-Tellez, Margarita ;
Pilatowsky-Figueroa, Isaac ;
Sarichez-Juarez, Aaron ;
Luis Fernandez-Zayas, Jose .
APPLIED THERMAL ENGINEERING, 2015, 75 :1192-1200
[7]  
Chittaranjan R., 2011, DRINKING WATER TREAT
[8]  
Duffie JA, 2013, SOLAR ENGINEERING OF THERMAL PROCESSES, 4TH EDITION, P1, DOI 10.1002/9781118671603
[9]   Thermal performance of a single basin solar still with PCM as a storage medium [J].
El-Sebaii, A. A. ;
Al-Ghamdi, A. A. ;
Al-Hazmi, F. S. ;
Faidah, Adel S. .
APPLIED ENERGY, 2009, 86 (7-8) :1187-1195
[10]   Effect of wind speed on active and passive solar stills [J].
El-Sebaii, AA .
ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (7-8) :1187-1204