Accelerated Three-dimensional T2-Weighted Turbo-Spin-Echo Sequences with Inner-Volume Excitation and Iterative Denoising in the Setting of Pelvis MRI at 1.5T: Impact on Image Quality and Lesion Detection

被引:1
作者
Almansour, Haidara [1 ]
Weiland, Elisabeth [2 ]
Kuehn, Bernd [2 ]
Kannengiesser, Stephan [2 ]
Gassenmaier, Sebastian [1 ]
Herrmann, Judith [1 ]
Hoffmann, Rueurodiger [1 ]
Othman, Ahmed E. [1 ,3 ]
Afat, Saif [1 ]
机构
[1] Eberhard Karls Univ Tubingen, Tuebingen Univ Hosp, Dept Diagnost & Intervent Radiol, Tubingen, Germany
[2] Siemens Healthcare GmbH, MR Applicat Predev, Erlangen, Germany
[3] Univ Med Ctr Mainz, Dept Neuroradiol, Mainz, Germany
关键词
Acceleration; pelvis MRI; iterative denoising; Multiplanar reconstructions; SPACE; 3D; IMPROVEMENT; ABDOMEN; SPACE;
D O I
10.1016/j.acra.2022.01.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: To investigate image quality and rate of lesion detection in a novel three-dimensional T2-weighted turbo-spin -echo sequence with inner-volume excitation (zoomed imaging) and iterative denoising processing in pelvic MRI at 1.5T. Two-dimensional T2-weighted turbo-spin-echo sequences were used as the clinical reference standard (2D-T2-TSE).Materials and Methods: This is a prospective study of patients with various pelvic pathologies. Each patient underwent standard 2D-T2-TSE in three planes with two-fold acceleration as well as a single three-dimensional T2-TSE in the sagittal plane with four-fold acceleration known as Sampling-Perfection-with-Application-optimized-Contrast-using-different-flip-angle-Evolutions (3D-T2-SPACE). The 3D-T2-SPACE images were reconstructed in three orthogonal planes at a slice thickness of 2 mm (vs. 2D-T2-TSE at 4 mm). Two radiologists conducted a qualitative image analysis on standard 2D-T2-TSE and multiplanar reconstructed 3D-T2-SPACE images. These parameters were compared and inter -reader agreement was computed. Furthermore, each reader documented the observed lesions of various pelvic organs. The rate of lesion detec-tion was compared between readers and sequences. Inter-reader and inter-sequence agreement were computed.Results: Forty patients (25 females) were included. Mean patient age was 58 </n> 13 years. 3D-T2-SPACE enabled an approximate 22% reduction of acquisition time and 50% of reconstructed slice thickness. 3D-T2-SPACE showed fewer artifacts than 2D-T2-TSE (p < 0.001). However, 2D-T2-TSE was rated to have significantly higher signal intensity than 3D-T2-SPACE (p < 0.001). There were no significant differ-ences between the two sequences regarding all other parameters. Inter-reader agreement regarding image quality parameters was substan-tial (Kappa = 0.772). For all analyzed pelvic anatomic structures, inter-reader and inter-sequence agreement for lesion detection was excellent (Kappa > 0.80).Conclusion: 3D-T2-SPACE with the inner-volume excitation and iterative denoising is clinically feasible at 1.5 T, enabling faster imaging, thinner slices, and significant reduction of artifacts. Despite that signal intensity was inferior in the SPACE images, overall image quality, diagnostic confidence and lesion detection were not compromised. This prospective study sets the stage for further clinical implementa-tion and future investigations tailored to specific indications in pelvis MRI.
引用
收藏
页码:E248 / E259
页数:12
相关论文
共 21 条
[1]   High spatial resolution 3D MR cholangiography with high sampling efficiency technique (SPACE): Comparison of 3 T vs. 1.5 T [J].
Arizono, Shigeki ;
Isoda, Hiroyoshi ;
Maetani, Yoji S. ;
Hirokawa, Yuusuke ;
Shimada, Kotaro ;
Nakamoto, Yuji ;
Shibata, Toshiya ;
Togashi, Kaori .
EUROPEAN JOURNAL OF RADIOLOGY, 2010, 73 (01) :114-118
[2]   Fast spin echo sequences with very long echo trains:: Design of variable refocusing flip angle schedules and generation of clinical T2 contrast [J].
Busse, RF ;
Hariharan, H ;
Vu, A ;
Brittain, JH .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (05) :1030-1037
[3]  
Florin M, 2021, INVEST RADIOL
[4]   Image Quality Improvement of Dynamic Contrast-Enhanced Gradient Echo Magnetic Resonance Imaging by Iterative Denoising and Edge Enhancement [J].
Gassenmaier, Sebastian ;
Herrmann, Judith ;
Nickel, Dominik ;
Kannengiesser, Stephan ;
Afat, Saif ;
Seith, Ferdinand ;
Hoffmann, Ruediger ;
Othman, Ahmed E. .
INVESTIGATIVE RADIOLOGY, 2021, 56 (07) :465-470
[5]   Application of a Novel Iterative Denoising and Image Enhancement Technique in T1-Weighted Precontrast and Postcontrast Gradient Echo Imaging of the Abdomen Improvement of Image Quality and Diagnostic Confidence [J].
Gassenmaier, Sebastian ;
Afat, Saif ;
Nickel, Dominik ;
Kannengiesser, Stephan ;
Herrmann, Judith ;
Hoffmann, Ruediger ;
Othman, Ahmed E. .
INVESTIGATIVE RADIOLOGY, 2021, 56 (05) :328-334
[6]   N/2 ghosting artifacts: Elimination at 3.0-T MR cholangiography with SPACE pulse sequence [J].
Haystead, Clare M. ;
Dale, Brian M. ;
Merkle, Elmar M. .
RADIOLOGY, 2008, 246 (02) :589-595
[7]   Hyperechoes [J].
Hennig, J ;
Scheffler, K .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (01) :6-12
[8]  
Kannengiesser SA, 2016, P ISMRM
[9]   Magnetic resonance imaging of the body trunk using a single-slab, 3-dimensional, T2-weighted turbo-spin-echo sequence with high sampling efficiency (SPACE) for high spatial resolution imaging -: Initial clinical experiences [J].
Lichy, MP ;
Wietek, BM ;
Mugler, JP ;
Horger, W ;
Menzel, MI ;
Anastasiadis, A ;
Siegmann, K ;
Niemeyer, T ;
Königsrainer, A ;
Kiefer, B ;
Schick, F ;
Claussen, CD ;
Schlemmer, HP .
INVESTIGATIVE RADIOLOGY, 2005, 40 (12) :754-760
[10]   Clinical applications of 3D T2-weighted MRI in pelvic imaging [J].
Lim, Kelvin K. ;
Noe, Geertje ;
Hornsey, Emma ;
Lim, Ruth P. .
ABDOMINAL IMAGING, 2014, 39 (05) :1052-1062