Rapid Detection of Circulating Breast Cancer Cells Using a Multiresonant Optical Fiber Aptasensor with Plasmonic Amplification

被引:140
作者
Loyez, Mederic [1 ]
Hassan, Eman M. [2 ]
Lobry, Maxime [3 ]
Liu, Fu [4 ]
Caucheteur, Christophe [3 ]
Wattiez, Ruddy [1 ]
DeRosa, Maria C. [2 ]
Willmore, William G. [5 ]
Albert, Jacques [4 ]
机构
[1] Univ Mons, Prote & Microbiol Dept, B-7000 Mons, Belgium
[2] Carleton Univ, Inst Biochem, Ottawa, ON K1S 5B6, Canada
[3] Univ Mons, Electromagnetism & Telecommun Dept, B-7000 Mons, Belgium
[4] Carleton Univ, Dept Elect, Ottawa, ON K1S 5B6, Canada
[5] Carleton Univ, Inst Chem, Ottawa, ON K1S 5B6, Canada
关键词
surface plasmon resonance; aptamer; mammaglobin; biomarker; breast cancer cells; biosensing; TUMOR-CELLS; RESONANCE; SENSORS; GOLD; BIOMARKER; DESIGN; MAMMAGLOBIN; GRATINGS; APTAMERS; PLATFORM;
D O I
10.1021/acssensors.9b02155
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The detection of circulating tumor cells (CTCs), which are responsible for metastasis in several forms of cancer, represents an important goal in ontological diagnosis and treatment. These cells remain extremely challenging to detect, despite numerous previous studies, due to their low concentration (1-10 cells/mL of blood). In this work, an all-fiber plasmonic aptasensor featuring multiple narrowband resonances in the near-infrared wavelength range was developed to detect metastatic breast cancer cells. To this aim, specific aptamers against mammaglobin-A were selected and immobilized as receptors on the sensor surface. In vitro assays confirm that the label-free and real-time detection of cancer cells [limit of detection (LOD) of 49 cells/mL] occurs within 5 min, while the additional use of functionalized gold nanoparticles allows a 2-fold amplification of the biosensor response. Differential measurements on selected optical resonances were used to process the sensor response, and results were confirmed by microscopy. The detection of only 10 cancer cells/mL was achieved with relevant specificity against control cells and with quick response time.
引用
收藏
页码:454 / 463
页数:19
相关论文
共 48 条
[1]   Tilted fiber Bragg grating sensors [J].
Albert, Jacques ;
Shao, Li-Yang ;
Caucheteur, Christophe .
LASER & PHOTONICS REVIEWS, 2013, 7 (01) :83-108
[2]  
[Anonymous], 2017, SENSORS BASEL, DOI DOI 10.3390/S17122732
[3]  
[Anonymous], 2019, MOLECULES
[4]   Long-period fiber grating: a specific design for biosensing applications [J].
Bandyopadhyay, Sankhyabrata ;
Biswas, Palas ;
Chiavaioli, Francesco ;
Dey, Tanoy Kumar ;
Basumallick, Nandini ;
Trono, Cosimo ;
Giannetti, Ambra ;
Tombelli, Sara ;
Baldini, Francesco ;
Bandyopadhyay, Somnath .
APPLIED OPTICS, 2017, 56 (35) :9846-9853
[5]   Clinical validity of circulating tumour cells in patients with metastatic breast cancer: a pooled analysis of individual patient data [J].
Bidard, Francois-Clement ;
Peeters, Dieter J. ;
Fehm, Tanja ;
Nole, Franco ;
Gisbert-Criado, Rafael ;
Mavroudis, Dimitrios ;
Grisanti, Salvatore ;
Generali, Daniele ;
Garcia-Saenz, Jose A. ;
Stebbing, Justin ;
Caldas, Carlos ;
Gazzaniga, Paola ;
Manso, Luis ;
Zamarchi, Rita ;
Fernandez de Lascoiti, Angela ;
De Mattos-Arruda, Leticia ;
Ignatiadis, Michail ;
Lebofsky, Ronald ;
van Laere, Steven J. ;
Meier-Stiegen, Franziska ;
Sandri, Maria-Teresa ;
Vidal-Martinez, Jose ;
Politaki, Eleni ;
Consoli, Francesca ;
Bottini, Alberto ;
Diaz-Rubio, Eduardo ;
Krell, Jonathan ;
Dawson, Sarah-Jane ;
Raimondi, Cristina ;
Rutten, Annemie ;
Janni, Wolfgang ;
Munzone, Elisabetta ;
Caranana, Vicente ;
Agelaki, Sofi A. ;
Almici, Camillo ;
Dirix, Luc ;
Solomayer, Erich-Franz ;
Zorzino, Laura ;
Johannes, Helene ;
Reis-Filho, Jorge S. ;
Pantel, Klaus ;
Pierga, Jean-Yves ;
Michiels, Stefan .
LANCET ONCOLOGY, 2014, 15 (04) :406-414
[6]  
Bray F, 2018, CA-CANCER J CLIN, V68, P394, DOI [10.3322/caac.21492, 10.3322/caac.21609]
[7]   Evaluation of gold layer configuration for plasmonic fiber grating biosensors [J].
Caucheteur, C. ;
Loyez, M. ;
Gonzalez-Vila, A. ;
Wattiez, R. .
OPTICS EXPRESS, 2018, 26 (18) :24154-24163
[8]   Review of plasmonic fiber optic biochemical sensors: improving the limit of detection [J].
Caucheteur, Christophe ;
Guo, Tuan ;
Albert, Jacques .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (14) :3883-3897
[9]   Near-infrared grating-assisted SPR optical fiber sensors: design rules for ultimate refractometric sensitivity [J].
Caucheteur, Christophe ;
Voisin, Valerie ;
Albert, Jacques .
OPTICS EXPRESS, 2015, 23 (03) :2918-2932
[10]   An easy way to realize SPR aptasensor: A multimode plastic optical fiber platform for cancer biomarkers detection [J].
Cennamo, Nunzio ;
Pesavento, Maria ;
Lunelli, Lorenzo ;
Vanzetti, Lia ;
Pederzolli, Cecilia ;
Zeni, Luigi ;
Pasquardini, Laura .
TALANTA, 2015, 140 :88-95