Cascaded analysis of signal and noise propagation through a heterogeneous breast model

被引:10
作者
Mainprize, James G. [1 ]
Yaffe, Martin J. [1 ,2 ]
机构
[1] Sunnybrook Hlth Sci Ctr, Toronto, ON M4N 3M5, Canada
[2] Univ Toronto, Dept Med Biophys, Toronto, ON M4N 3M5, Canada
关键词
anatomic noise; mammography; cascaded systems; breast density; POWER-LAW NOISE; HUMAN-OBSERVER; TOMOSYNTHESIS; VARIABILITY; MAMMOGRAPHY; PERFORMANCE; SIMULATION; IMAGES;
D O I
10.1118/1.3483095
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The detectability of lesions in radiographic images can be impaired by patterns caused by the surrounding anatomic structures. The presence of such patterns is often referred to as anatomic noise. Others have previously extended signal and noise propagation theory to include variable background structure as an additional noise term and used in simulations for analysis by human and ideal observers. Here, the analytic forms of the signal and noise transfer are derived to obtain an exact expression for any input random distribution and the "power law" filter used to generate the texture of the tissue distribution. Methods: A cascaded analysis of propagation through a heterogeneous model is derived for x-ray projection through simulated heterogeneous backgrounds. This is achieved by considering transmission through the breast as a correlated amplification point process. The analytic forms of the cascaded analysis were compared to monoenergetic Monte Carlo simulations of x-ray propagation through power law structured backgrounds. Results: As expected, it was found that although the quantum noise power component scales linearly with the x-ray signal, the anatomic noise will scale with the square of the x-ray signal. There was a good agreement between results obtained using analytic expressions for the noise power and those from Monte Carlo simulations for different background textures, random input functions, and x-ray fluence. Conclusions: Analytic equations for the signal and noise properties of heterogeneous backgrounds were derived. These may be used in direct analysis or as a tool to validate simulations in evaluating detectability. (C) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3483095]
引用
收藏
页码:5243 / 5250
页数:8
相关论文
共 15 条
[1]   Human- and model-observer performance in ramp-spectrum noise: effects of regularization and object variability [J].
Abbey, CK ;
Barrett, HH .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2001, 18 (03) :473-488
[2]  
Barrett H.H., 1989, PROCSPIE MEDICAL IMA, V1090, P176, DOI DOI 10.1117/12.953202
[3]   OBJECTIVE ASSESSMENT OF IMAGE QUALITY .2. FISHER INFORMATION, FOURIER CROSSTALK, AND FIGURES OF MERIT FOR TASK-PERFORMANCE [J].
BARRETT, HH ;
DENNY, JL ;
WAGNER, RF ;
MYERS, KJ .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1995, 12 (05) :834-852
[4]   A three-dimensional breast software phantom for mammography simulation [J].
Bliznakova, K ;
Bliznakov, Z ;
Bravou, V ;
Kolitsi, Z ;
Pallikarakis, N .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (22) :3699-3719
[5]   Statistical texture synthesis of mammographic images with clustered lumpy backgrounds [J].
Bochud, FO ;
Abbey, CK ;
Eckstein, MP .
OPTICS EXPRESS, 1999, 4 (01) :33-43
[6]   Human observer detection experiments with mammograms and power-law noise [J].
Burgess, AE ;
Jacobson, FL ;
Judy, PF .
MEDICAL PHYSICS, 2001, 28 (04) :419-437
[7]   Signal detection in power-law noise: effect of spectrum exponents [J].
Burgess, Arthur E. ;
Judy, Philip E. .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2007, 24 (12) :B52-B60
[8]   CHARACTERIZATION OF MAMMOGRAPHIC PARENCHYMAL PATTERN BY FRACTAL DIMENSION [J].
CALDWELL, CB ;
STAPLETON, SJ ;
HOLDSWORTH, DW ;
JONG, RA ;
WEISER, WJ ;
COOKE, G ;
YAFFE, MJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (02) :235-247
[9]   A computer simulation study comparing lesion detection accuracy with digital mammography, breast tomosynthesis, and cone-beam CT breast imaging [J].
Gong, X ;
Glick, SJ ;
Liu, B ;
Vedula, AA ;
Thacker, S .
MEDICAL PHYSICS, 2006, 33 (04) :1041-1052
[10]   Characterizing anatomical variability in breast CT images [J].
Metheany, Kathrine G. ;
Abbey, Craig K. ;
Packard, Nathan ;
Boone, John M. .
MEDICAL PHYSICS, 2008, 35 (10) :4685-4694