Cecal intubation time between cap-assisted water exchange and water exchange colonoscopy: a randomized-controlled trial

被引:10
作者
Tseng, Chih-Wei [1 ,3 ]
Koo, Malcolm [2 ,4 ]
Hsieh, Yu-Hsi [1 ,3 ]
机构
[1] Buddhist Tzu Chi Med Fdn, Dalin Tzu Chi Hosp, Div Gastroenterol, Dept Internal Med, Chiayi, Taiwan
[2] Buddhist Tzu Chi Med Fdn, Dalin Tzu Chi Hosp, Dept Med Res, Chiayi, Taiwan
[3] Tzu Chi Univ, Sch Med, Hualien, Taiwan
[4] Univ Toronto, Dalla Lana Sch Publ Hlth, Toronto, ON, Canada
关键词
adenoma detection rate; cap-assisted water exchange; cecal intubation time; colonoscopy; water exchange; CARBON-DIOXIDE INSUFFLATION; ON-DEMAND SEDATION; ADENOMA DETECTION; UNSEDATED COLONOSCOPY; REGULAR COLONOSCOPY; TRANSPARENT HOOD; AIR INSUFFLATION; IMMERSION; IMPACT; METAANALYSIS;
D O I
10.1097/MEG.0000000000000954
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and aim The water exchange (WE) method can decrease the discomfort of the patients undergoing colonoscopy. It also provides salvage cleansing and improves adenoma detection, but a longer intubation time is required. Cap-assisted colonoscopy leads to a significant reduction in cecal intubation time compared with traditional colonoscopy with air insufflation. The aim of this study was to investigate whether combined cap-assisted colonoscopy and water exchange (CWE) could decrease the cecal intubation time compared with WE. Patients and methods A total of 120 patients undergoing fully sedated colonoscopy at a regional hospital in southern Taiwan were randomized to colonoscopy with either CWE (n = 59) or WE (n= 61). The primary endpoint was cecal intubation time. Results The mean cecal intubation time was significantly shorter in CWE (12.0 min) compared with WE (14.8 min) (P= 0.004). The volume of infused water during insertion was lower in CWE (840 ml) compared with WE (1044 ml) (P = 0.003). The adenoma detection rate was 50.8 and 47.5% for CWE and WE, respectively (P= 0.472). The Boston Bowel Preparation Scale scores were comparable in the two groups. Results from the multiple linear regression analysis indicated that WE with a cap, a higher degree of endoscopist's experience, a higher Boston Bowel Preparation Scale score, and a lower volume of water infused during insertion, without abdominal compression, without change of position, and without chronic laxative use, were significantly associated with a shorter cecal intubation time. Conclusion In comparison with WE, CWE could shorten the cecal intubation time and required lower volume of water infusion during insertion without compromising the cleansing effect of WE. Copyright (C) 2017 Wolters Kluwer Health, Inc. All rights reserved.
引用
收藏
页码:1296 / 1302
页数:7
相关论文
共 50 条
  • [31] Higher adenoma detection rates with cap-assisted colonoscopy: a randomised controlled trial
    Rastogi, Amit
    Bansal, Ajay
    Rao, Deepthi S.
    Gupta, Neil
    Wani, Sachin B.
    Shipe, Tracy
    Gaddam, Srinivas
    Singh, Vikas
    Sharma, Prateek
    GUT, 2012, 61 (03) : 402 - 408
  • [32] Randomized Trial Comparing Left Colon Mucus Production Using Water vs Saline During Water Exchange Colonoscopy
    Cheng, Chi-Liang
    Kuo, Yen-Lin
    Liu, Nai-Jen
    Lien, Jau-Min
    Su, I-Chia
    Tang, Chia-Pei
    Hsieh, Yu-Hsi
    Leung, Felix W.
    CLINICAL AND TRANSLATIONAL GASTROENTEROLOGY, 2023, 14 (07) : e00594
  • [33] Prospective multicenter randomized controlled trial comparing adenoma detection rate in colonoscopy using water exchange, water immersion, and air insufflation
    Hsieh, Yu-Hsi
    Tseng, Chih-Wei
    Hu, Chi-Tan
    Koo, Malcolm
    Leung, Felix W.
    GASTROINTESTINAL ENDOSCOPY, 2017, 86 (01) : 192 - 201
  • [34] Standard versus Endocuff versus cap-assisted colonoscopy for adenoma detection: A randomised controlled clinical trial
    Floer, Martin
    Tschaikowski, Laura
    Schepke, Michael
    Kempinski, Radoslaw
    Neubauer, Katarzyna
    Poniewierka, Elzbieta
    Kunsch, Steffen
    Ameis, Detlev
    Heinzow, Hauke Sebastian
    Auer, Agneta
    Schmidt, Hartmut H.
    Ellenrieder, Volker
    Meister, Tobias
    UNITED EUROPEAN GASTROENTEROLOGY JOURNAL, 2021, 9 (04) : 443 - 450
  • [35] Adenoma and Advanced Adenoma Detection Rates of Water Exchange, Endocuff, and Cap Colonoscopy: A Network Meta-Analysis with Pooled Data of Randomized Controlled Trials
    Shao, Paul P.
    Bui, Aileen
    Romero, Tahmineh
    Jia, Hui
    Leung, Felix W.
    DIGESTIVE DISEASES AND SCIENCES, 2021, 66 (04) : 1175 - 1188
  • [36] Water exchange colonoscopy increases adenoma detection rate: a systematic review with network meta-analysis of randomized controlled studies
    Fuccio, Lorenzo
    Frazzoni, Leonardo
    Hassan, Cesare
    La Marca, Marina
    Paci, Valentina
    Smania, Veronica
    De Bortoli, Nicola
    Bazzoli, Franco
    Repici, Alessandro
    Rex, Douglas
    Cadoni, Sergio
    GASTROINTESTINAL ENDOSCOPY, 2018, 88 (04) : 589 - +
  • [37] Effect of Abdominal Corset on Completion of Colonoscopy and Cecal and Ileocecal Intubation Time in Patients with Central Obesity: A Prospective Randomized Controlled Trial
    Gundes, Ebubekir
    Ofkeli, Ozcem
    Uzun, Orhan
    Senger, Aziz Serkan
    Polat, Erdal
    Duman, Mustafa
    ANNALI ITALIANI DI CHIRURGIA, 2024, 95 (04) : 603 - 608
  • [38] A Patient-Blinded Randomized, Controlled Trial Comparing Air Insufflation, Water Immersion, and Water Exchange During Minimally Sedated Colonoscopy
    Hsieh, Yu-Hsi
    Koo, Malcolm
    Leung, Felix W.
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2014, 109 (09) : 1390 - 1400
  • [39] Comparison of Right Colon Adenoma Miss Rates Between Water Exchange and Carbon Dioxide Insufflation A Prospective Randomized Controlled Trial
    Cheng, Chi-Liang
    Kuo, Yen-Lin
    Hsieh, Yu-Hsi
    Tang, Jui-Hsiang
    Leung, Felix W.
    JOURNAL OF CLINICAL GASTROENTEROLOGY, 2021, 55 (10) : 869 - 875
  • [40] Clinical value of sigmoid colon water exchange colonoscopy: a prospective randomized clinical trial
    Jiao, Tian-Xiao
    Hu, Yang
    Guo, Shi-Bin
    SCIENTIFIC REPORTS, 2023, 13 (01)