Practical time-gated luminescence flow cytometry. II: Experimental evaluation using UV LED excitation

被引:30
作者
Jin, Dayong [1 ]
Connally, Russell [1 ]
Piper, James [1 ]
机构
[1] Macquarie Univ, Ctr Lasers & Applicat, Div Informat & Commun Sci, N Ryde, NSW 2109, Australia
关键词
UV LED; europium; lanthanide; microsphere; time-gated luminescence; flow cytometry; autofluorescence; Giardia; counting efficiency;
D O I
10.1002/cyto.a.20449
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In the previous article [Part 1 (8)], we have modelled alternative approaches to design of practical time-gated luminescence (TGL) flow cytometry and examined the feasibility of employing a UV LED as the excitation source for the gated detection of europium dye labelled target in rapid flow stream. The continuous flow-section approach is well suited for rare-event cell counting in applications with a large number of nontarget autofluorescent particles. This article presents details of construction, operation and evaluation of a TGL flow cytometer using a UV LED excitation and a gated high-gain channel photomultiplier tube (CPMT) for detection. The compact prototype TGL flow cytometer was constructed and optimised to operate at a TGL cycle rate of 6 kHz, with each cycle consisting of 100 mu s LED pulsed excitation and similar to 60 mu s delay-gated detection. The performance of the TGL flow cytometer was evaluated by enumerating 5.7 Put, Eu3+ luminescence beads (having comparable intensity to europium-chelate-labeled Giardia cysts) in both autofluorescence-rich environmental water concentrates and Sulforhodamine 101 (S101) solutions (broadband red fluorescence covering the spectral band of target signals), respectively. The prototype TGL flow cytometer was able to distinguish the target beads, and a maximum signal to background ratio of 38:1 was observed. Neither the environmental water concentrates nor S101 solution contributed to the background in the TGL detection phase. The counting efficiency of the TGL flow cytometer was typically >93% of values determined using conventional counting methods. (C) 2007 International Society for Analytical Cytology.
引用
收藏
页码:797 / 808
页数:12
相关论文
共 28 条
[1]   Time-resolved fluorescence microscopy using an improved europium chelate BHHST for the in situ detection of Cryptosporidium and Giardia [J].
Connally, R ;
Veal, D ;
Piper, J .
MICROSCOPY RESEARCH AND TECHNIQUE, 2004, 64 (04) :312-322
[2]  
CONNALLY R, 2005, SPIE P, V5699, P93
[3]   High intensity solid-state UV source for time-gated luminescence microscopy [J].
Connally, Russell ;
Jin, Dayong ;
Piper, James .
CYTOMETRY PART A, 2006, 69A (09) :1020-1027
[4]   Foodborne protozoan parasites [J].
Dawson, D .
INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2005, 103 (02) :207-227
[5]  
Ferrari BC, 2000, CYTOMETRY, V41, P216, DOI 10.1002/1097-0320(20001101)41:3&lt
[6]  
216::AID-CYTO9&gt
[7]  
3.0.CO
[8]  
2-R
[9]   Combination of a gated photomultiplier tube and a phase sensitive detector for use in an intensive pulsed background light situation [J].
Iwata, T ;
Takasu, T ;
Miyata, T ;
Araki, T .
OPTICAL REVIEW, 2002, 9 (01) :18-24
[10]   Long-lived visible luminescence of UV LEDs and impact on LED excited time-resolved fluorescence applications [J].
Jin, D ;
Connally, R ;
Piper, J .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2006, 39 (03) :461-465