Reversible 3D compression of segmented medical volumes: usability analysis for teleradiology and storage

被引:3
作者
Aldemir, Erdogan [1 ]
Gezer, Naciye Sinem [2 ]
Tohumoglu, Gulay [3 ]
Baris, Mustafa [2 ]
Kavur, A. Emre [1 ]
Dicle, Oguz [2 ]
Selver, M. Alper [3 ]
机构
[1] Dokuz Eylul Univ, Grad Sch Nat & Appl Sci, DEU Tinaztepe Campus 22, TR-35390 Izmir, Turkey
[2] Dokuz Eylul Univ, Med Sch, Dept Radiol, Mithatpasa St,Inciralti Campus, TR-35340 Narlidere Izmir, Turkey
[3] Dokuz Eylul Univ, Elect & Elect Engn Dept, DEU Kaynaklar Campus 22, TR-35090 Izmir, Turkey
关键词
DICOM; reversible compression; segmentation; teleradiology; visualization; LOSSLESS COMPRESSION; FILE FORMATS; IMAGES; DICOM; ALGORITHMS; 2D;
D O I
10.1002/mp.14053
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background DICOM standard does not have modules that provide the possibilities of two-dimensional Presentation States to three-dimensional (3D). Once the final 3D rendering is obtained, only video/image exporting or snapshots can be used. To increase the utility of 3D Presentation States in clinical practice and teleradiology, the storing and transferring the segmentation results, obtained after tedious procedures, can be very effective. Purpose To propose a strategy for preserving interaction and mobility of visualizations for teleradiology by storing and transferring only binary segmented data, which is effectively compressed by modern adaptive and context-based reversible methods. Material and Methods A diverse set of segmented data, which include four abdominal organs (liver, spleen, right, and left kidneys) from 20 T1-DUAL and 20 T2-SPIR MRI, liver from 20 CT, and abdominal aorta with aneurysms (AAA) from 19 computed tomography-angiography datasets, are collected. Each organ is segmented manually by expert physicians, and binary volumes are created. The well-established reversible binary compression methods PNG, JPEG-LS, JPEG-XR, CCITT-G4, LZW, JBIG2, and ZIP are applied to medical datasets. Recently proposed context-based (3D-RLE) and adaptive (ABIC) algorithms are also employed. The performance assessment has been presented in terms of the compression ratio that is a universal compression metric. Results Reversible compression of binary volumes results with substantial decreases in file size such as 254 to 2.14 MB for CT-AAA, 56.7 to 0.3 MB for CT-liver. Moreover, compared to the performance of well-established methods (i.e., mean 76.14%), CR is observed to be increased significantly for all segmented organs from both CT and MRI datasets when ABIC (95.49%) and 3D-RLE (94.98%) are utilized. The hypothesis is that morphological coherence of scanning procedure and adaptation between the segmented organs, that is, bi-level images, contributes to compression performance. Although the performance of well-established techniques is satisfactory, the sensitivity of ABIC to modality type and the advantage of 3D-RLE when the spatial coherence between the adjacent slices are high results with up to 10 times more CR performance. Conclusion Adaptive and context-based compression strategies allow effective storage and transfer of segmented binary data, which can be used to re-produce visualizations for better teleradiology practices preserving all interaction mechanisms.
引用
收藏
页码:1727 / 1737
页数:11
相关论文
共 42 条
[1]  
Aldemir E, 2018, RAD SOC N AM 2018 SC
[2]   Binary medical image compression using the volumetric run-length approach [J].
Aldemir, Erdogan ;
Tohumoglu, Gulay ;
Selver, M. Alper .
IMAGING SCIENCE JOURNAL, 2019, 67 (03) :123-135
[3]   Optimizing Analysis, Visualization, and Navigation of Large Image Data Sets: One 5000-Section CT Scan Can Ruin Your Whole Day [J].
Andriole, Katherine P. ;
Wolfe, Jeremy M. ;
Khorasani, Ramin ;
Treves, S. Ted ;
Getty, David J. ;
Jacobson, Francine L. ;
Steigner, Michael L. ;
Pan, John J. ;
Sitek, Arkadiusz ;
Seltzer, Steven E. .
RADIOLOGY, 2011, 259 (02) :346-362
[4]   Watermark Compression in Medical Image Watermarking Using Lempel-Ziv-Welch (LZW) Lossless Compression Technique [J].
Badshah, Gran ;
Liew, Siau-Chuin ;
Zain, Jasni Mohd ;
Ali, Mushtaq .
JOURNAL OF DIGITAL IMAGING, 2016, 29 (02) :216-225
[5]   Off-site teleradiology: The pros [J].
Bradley, William G., Jr. .
RADIOLOGY, 2008, 248 (02) :337-341
[6]   An easy measure of compactness for 2D and 3D shapes [J].
Bribiesca, Ernesto .
PATTERN RECOGNITION, 2008, 41 (02) :543-554
[7]   Data compression technology in ASIC cores [J].
Burroughs, SH ;
Lattrell, TR .
IBM JOURNAL OF RESEARCH AND DEVELOPMENT, 1998, 42 (06) :725-731
[8]  
Cai C, 2019, IEEE T IMAGE PROCESS, V14, P1
[9]   High-capacity reversible data hiding in encrypted images based on extended run-length coding and block-based MSB plane rearrangement [J].
Chen, Kaimeng ;
Chang, Chin-Chen .
JOURNAL OF VISUAL COMMUNICATION AND IMAGE REPRESENTATION, 2019, 58 :334-344
[10]   Lossless compression of grayscale medical images - Effectiveness of traditional and state of the art approaches [J].
Clunie, DA .
MEDICAL IMAGING 2000: PACS DESIGN AND EVALUATION - ENGINEERING AND CLINICAL ISSUES, 2000, 3980 :74-84