HDPE geogrid-residual soil interaction under monotonic and cyclic pullout loading

被引:33
作者
Ferreira, E. B. [1 ]
Vieira, C. S. [1 ]
Lopes, M. L. [1 ]
Ferreira, P. G. [2 ]
机构
[1] Univ Porto, Fac Engn, CONSTRUCT GEO, R Dr Roberto Frias, Porto, Portugal
[2] Univ Porto, Fac Engn, CONSTRUCT ViBest, R Dr Roberto Frias, Porto, Portugal
关键词
Geosynthetics; Pullout tests; Cyclic loading; HDPE uniaxial geogrid; Granite residual soil; Frequency; Amplitude; DIRECT SHEAR; MOISTURE CONTENT; OUT RESISTANCE; SCALE PULLOUT; BEHAVIOR; GEOSYNTHETICS; REINFORCEMENT; DEFORMATION; STRENGTH; DENSITY;
D O I
10.1680/jgein.19.00057
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
The understanding of soil-geosynthetic interaction under cyclic loading conditions is essential for the safe design of geosynthetic-reinforced soil structures subjected to repeated loads, such as those induced by road and railway traffic and earthquakes. This paper describes a series of large-scale monotonic and multistage pullout tests carried out to investigate the behaviour of an HDPE uniaxial geogrid embedded in a locally available granite residual soil under monotonic and cyclic pullout loading. The effects of the pullout load level at the start of the cyclic stage, cyclic load frequency and amplitude, number of cycles and soil density on the load-strain-displacement response of the reinforcement are evaluated and discussed. Test results show that the cumulative displacements measured along the length of the geogrid during cyclic loading increased significantly with the precyclic pullout load level and the load amplitude. In contrast, the cumulative cyclic displacements were found to decrease with increasing frequency and soil density. In medium dense soil conditions, the geogrid post-cyclic pullout resistance decreased by up to 20%, with respect to the value obtained in the comparable monotonic test. However, for dense soil, the effect of cyclic loading on the peak pullout forces recorded during the tests was almost negligible.
引用
收藏
页码:79 / 96
页数:18
相关论文
共 61 条
[1]  
AASHTO, 2017, LRFD bridge design specifications. Customary U.S. units, V8th
[2]  
Abdel-Rahman A. H., 2011, GEOTECHNICAL SPECIAL, V2011, P3087
[3]   Observed long-term performance of geosynthetic walls and implications for design [J].
Allen, TM ;
Bathurst, RJ .
GEOSYNTHETICS INTERNATIONAL, 2002, 9 (5-6) :567-606
[4]  
[Anonymous], 2006, Canadian Foundation Engineering Manual
[5]  
[Anonymous], D248711 ASTM INT
[6]  
[Anonymous], 1995, THESIS
[7]  
Bathurst R.J., 1994, GEOSYNTH INT, V1, P1, DOI DOI 10.1680/GEIN.1.0001
[8]  
Bernardi M., 2010, DESIGN MANUAL SEGMEN, P22
[9]  
BSI, 1995, BS8006
[10]   The influence of a cyclic loading history on soil-geogrid interaction under pullout condition [J].
Cardile, G. ;
Pisano, M. ;
Moraci, N. .
GEOTEXTILES AND GEOMEMBRANES, 2019, 47 (04) :552-565