Delayed Presentation Injury of Descending Aorta and Bronchus Due to Sewing Needle Penetration: A Case Report

被引:0
|
作者
Chen, Huaidong [1 ]
Wang, Shiqiang [1 ]
Zheng, Dingwen [1 ]
He, Fan [1 ]
机构
[1] Zhejiang Univ, Sch Med, Sir Run Run Shaw Hosp, Dept Cardiac Surg, Hangzhou, Peoples R China
关键词
TRACHEAL FOREIGN-BODY; BODIES; REMOVAL;
D O I
10.1532/hsf.4461
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We report a case of a tracheal foreign body caused by a sewing needle. After about four months, the patient showed delayed dry cough and hemoptysis. The sewing needle that pierced the tracheal wall damaged the aorta, and we performed endovascular stenting to prevent arterial bleeding and removed it under a bronchoscope. The patient smoothly recovered after the operation. This case proves that treatment strategies for patients with foreign bodies in the trachea can be individualized.
引用
收藏
页码:E253 / E255
页数:3
相关论文
共 8 条
  • [1] Thoracoscopic retrieval of an intrapulmonary sewing needle: A case report
    Messaoudi, Houssem
    Ben Ismail, Imen
    Ragmoun, Wafa
    Lahdhili, Hatem
    Hachicha, Saber
    Chenik, Slim
    CLINICAL CASE REPORTS, 2020, 8 (12): : 2494 - 2497
  • [2] Spontaneous passage of ingested sewing needle: A case report
    Molla, Yohannis Derbew
    Gelaw, Tewodros Baye
    Alemu, Hirut Tesfahun
    Kassie, Melaku Tessema
    Sisay, Menarguachew Atanaw
    CLINICAL CASE REPORTS, 2024, 12 (05):
  • [3] Ileocecal junction perforation caused by a sewing needle in incarcerated inguinal hernia: An unusual case report
    Liu, Shiqi
    Li, Qifeng
    Li, Yumei
    Lv, Yi
    Niu, Jianhua
    Xu, Quan
    Zhao, Jingru
    Chen, Yajun
    Wang, Dayong
    Bai, Ruimiao
    MEDICINE, 2018, 97 (22)
  • [4] Retrieval of a broken sewing needle from the sacrum aided by a permanent magnet: a case report and literature review
    Fan, Jian
    Wang, Ming-Ming
    Liu, Yu-Ping
    OPEN MEDICINE, 2017, 12 (01): : 446 - 449
  • [5] Delayed Presentation of Thoracic Aortic Pseudoaneurysm Following Pedicle Screw Implantation: A Case Report
    Liu, Li-di
    Hong, Xin
    Li, Jiang-bi
    Zhang, Shao-kun
    ORTHOPAEDIC SURGERY, 2021, 13 (01) : 338 - 341
  • [6] Acute penetrating injury of the spinal cord by a wooden spike with delayed surgery: a case report
    Guest, James D.
    Luo, Zhuojing
    Liu, Yansheng
    Gao, Hongkun
    Wang, Dianchun
    Xu, Xiao-Ming
    Zhu, Hui
    NEURAL REGENERATION RESEARCH, 2023, 18 (12) : 2781 - 2784
  • [7] Delayed Small Bowel Obstruction Due to Intra-Abdominal Drain: Case Report and Literature Review
    Yang, Mei
    Kidane, Biniam
    Saettler, Elizabeth
    INTERNATIONAL SURGERY, 2018, 103 (3-4) : 149 - 153
  • [8] Instantaneous Death Due to Transorbital Reverse Penetration of a Screw in an Accidental Fall Unusual Autopsy Case Report and Review of the Literature
    Gioia, Sara
    Bacci, Mauro
    Lancia, Massimo
    Carlini, Luigi
    Suadoni, Fabio
    AMERICAN JOURNAL OF FORENSIC MEDICINE AND PATHOLOGY, 2014, 35 (01) : 15 - 19