An in-situ calibration device for portable gamma dosimeters based on minitype reference radiation

被引:0
|
作者
Liu, Y. [1 ,2 ]
Chen, Z. [1 ]
Qian, Y. [2 ,3 ]
Zhang, S. [2 ,3 ]
Feng, P. [3 ]
Mao, B. [2 ]
机构
[1] Tsinghua Univ, Dept Engn Phys, Beijing 100084, Peoples R China
[2] China Acad Engn Phys, Inst Nucl Phys & Chem, Mianyang 621999, Sichuan, Peoples R China
[3] Chongqing Univ, Minist Educ, Key Lab Optoelect Technol & Syst, Chongqing 400044, Peoples R China
基金
中国国家自然科学基金;
关键词
Dosimetry concepts and apparatus; Radiation damage monitoring systems;
D O I
10.1088/1748-0221/14/10/P10012
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper reports an in-situ calibration device for portable gamma dosimeters based on the minitype reference radiation (MRR). Compared to the standard reference radiation (SRR) regulated by the ISO-4037 series standards for gamma dosimeter calibration purposes, the dimensions of the MRR of the device were drastically reduced to 0.6 m x 0.6 m x 0.6 m, and the total weight of the device was approximately 800 kg. According to the test experiments, the device met the radiation protection requirements, and the air kerma rate range covered 1 mu Gy/h-10 mGy/h, which is appropriate for calibrating protection level gamma dosimeters. A series of dosimeters were calibrated in the SRR and the device, and the mean deviation of the calibration factors was approximately 5.66%.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Speckle-based portable device for in-situ metrology of X-ray mirrors at Diamond Light Source
    Wang, Hongchang
    Kashyap, Yogesh
    Zhou, Tunhe
    Sawhney, Kawal
    ADVANCES IN METROLOGY FOR X-RAY AND EUV OPTICS VII, 2017, 10385
  • [32] 671 nm Microsystem Diode Laser Based Portable Raman Sensor Device for In-situ Identification of Meat Spoilage
    Sowoidnich, Kay
    Schmidt, Heinar
    Schwaegele, Fredi
    Kronfeldt, Heinz-Detlef
    ADVANCED ENVIRONMENTAL, CHEMICAL, AND BIOLOGICAL SENSING TECHNOLOGIES VIII, 2011, 8024
  • [33] A novel optical shadow edge imaging method based fast in-situ measuring portable device for droplet deposition
    Liu, Jian
    Yu, Shihui
    Liu, Xuemei
    Wang, Qingde
    Cui, Huiyuan
    Zhu, Yunpeng
    Yuan, Jin
    COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2024, 217
  • [34] In-situ calibration of laser/galvo scanning system using dimensional reference artefacts
    Yeung, H.
    Lane, B. M.
    Donmez, M. A.
    Moylan, S.
    CIRP ANNALS-MANUFACTURING TECHNOLOGY, 2020, 69 (01) : 441 - 444
  • [35] Design of portable radiation-shielding device for gamma radiography of pipe welds
    Silva, JADE
    PROCEEDINGS OF THE TOPICAL MEETING ON RADIATION PROTECTION FOR OUR NATIONAL PRIORITIES: MEDICINE, THE ENVIRONMENT, AND THE LEGACY, 2000, : 535 - 540
  • [36] Performance standard on the calibration of germanium detectors for in-situ gamma ray measurements.
    Shebell, P
    HEALTH PHYSICS, 2002, 82 (06): : S194 - S195
  • [37] A smartphone-based calibration-free portable urinalysis device
    Guo Dong
    Li Gen
    Miao Jia-qi
    Shen Ya-jing
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2021, 28 (12) : 3829 - 3837
  • [38] RADIATION-PROOF GAMMA DOSIMETERS BASED ON MONOCRYSTALS OF CDS WITH COMPENSATING CONSTITUENTS
    KOPAS, NF
    KONOZENK.ID
    GALUSHKA, AP
    PRIBORY I TEKHNIKA EKSPERIMENTA, 1972, (05): : 59 - &
  • [39] Calibration of a HPGe detector for in-situ gamma spectrometry: a comparison between a Monte Carlo based code and an experimental method
    D'Alberti, F
    Forte, M
    Natural Radiation Environment VII, 2005, 7 : 198 - 206
  • [40] Study on in-situ calibration for neutron monitor in the helical type fusion experimental device based on monte carlo calculations
    Nakano, Yuji
    Yamazaki, Atsushi
    Watanabe, Kenichi
    Uritani, Akira
    Ogawa, Kunihiro
    Isobe, Mitsutaka
    Plasma and Fusion Research, 2014, 9 (SpecialIssue2)