Ultra fast electron beam X-ray computed tomography for two-phase flow measurement

被引:87
作者
Fischer, F. [1 ]
Hampel, U. [1 ]
机构
[1] Forschungszentrum Dresden Rossendorf eV, Inst Safety Res, D-01314 Dresden, Germany
关键词
D O I
10.1016/j.nucengdes.2009.11.016
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Electron beam X-ray CT is a new technique for a fast measurement of multiphase flows with frame rates of 1000 images per second and more. It gives, in principle, quantitatively accurate images of the flow at high spatial resolution and it is non-intrusive since moderately radiation absorbing vessel walls can be penetrated by X-rays. However, on the road to a technical realisation of such a technique within a computed tomography system many problems have to be solved. As a first prototype for scientific flow measurement studies, we devised and built a fast scanned electron beam X-ray tomography scanner. The scanner consists of an electron beam unit that can be operated at up to 150 kV acceleration voltage and up to 65 mA electron beam current, with the required electron optics for beam adjustment, beam focusing and beam deflection unit and a fast circular CZT detector comprising 240 elements of 1.5 mm x 1.5 mm x 1.5 mm active pixel area. X-ray radiation is produced on a circular water cooled tungsten target. The CT system achieves up to 7000 frames per second with a spatial resolution of 1 mm. First two-phase flow experiments have been carried out on gas-water flows in bubble columns. Further, a vertical test section made of titanium alloy has been installed at the TOPFLOW facility and will be used in future to study the evolution of two-phase gas-water pipe flow at high pressures and temperatures. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:2254 / 2259
页数:6
相关论文
共 10 条
  • [1] Evaluation of a limited angle scanned electron beam x-ray CT approach for two-phase pipe flows
    Bieberle, M.
    Hampel, U.
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2006, 17 (08) : 2057 - 2065
  • [2] Ultrafast limited-angle-type x-ray tomography
    Bieberle, M.
    Fischer, F.
    Schleicher, E.
    Hampel, U.
    Koch, D.
    Aktay, K. S. D. C.
    Menz, H.-J.
    Mayer, H.-G.
    [J]. APPLIED PHYSICS LETTERS, 2007, 91 (12)
  • [3] CARDIAC COMPUTED-TOMOGRAPHY
    BOYD, DP
    LIPTON, MJ
    [J]. PROCEEDINGS OF THE IEEE, 1983, 71 (03) : 298 - 307
  • [4] An ultra fast electron beam x-ray tomography scanner
    Fischer, F.
    Hoppe, D.
    Schleicher, E.
    Mattausch, G.
    Flaske, H.
    Bartel, R.
    Hampel, U.
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2008, 19 (09)
  • [5] GOULD RG, 1992, COMPUTED TOMOGRAPHY
  • [6] Experimental ultra fast X-ray computed tomography with a linearly scanned electron beam source
    Hampel, U
    Speck, M
    Koch, D
    Menz, HJ
    Mayer, HG
    Fietz, J
    Hoppe, D
    Schleicher, E
    Zippe, C
    Prasser, HM
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 2005, 16 (2-3) : 65 - 72
  • [7] Kak A.C. Slaney M., 1999, PRINCIPLES COMPUTERI
  • [8] The multipurpose thermalhydraulic test facility TOPFLOW:: an overview on experimental capabilities, instrumentation and results
    Prasser, H. -M.
    Beyer, M.
    Carl, H.
    Manera, A.
    Pietruske, H.
    Schuetz, P.
    Weiss, F-P.
    [J]. KERNTECHNIK, 2006, 71 (04) : 163 - 173
  • [9] A new electrode-mesh tomograph for gas-liquid flows
    Prasser, HM
    Bottger, A
    Zschau, J
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 1998, 9 (02) : 111 - 119
  • [10] SPECK M, 2005, P 4 WORLD C IND PROC, P681