Comparison of a New Matrix-Assisted Laser Desorption/lonization Time-of-Flight Mass Spectrometry Platform, ASTA MicrolDSys, With Bruker Biotyper for Species Identification

被引:14
|
作者
Lee, Yangsoon [1 ]
Sung, Ji Yeon [2 ]
Kim, Hyunsoo [3 ]
Yong, Dongeun [2 ]
Lee, Kyungwon [2 ]
机构
[1] Hanyang Univ, Coll Med, Dept Lab Med, Seoul, South Korea
[2] Yonsei Univ, Coll Med, Res Inst Bacterial Resistance, Dept Lab Med,Severance Hosp, Seoul, South Korea
[3] Natl Police Hosp, Dept Lab Med, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
MicrolDSys; Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry; Bruker Biotyper; DESORPTION IONIZATION-TIME; ROUTINE IDENTIFICATION; MICROFLEX LT; MS; SYSTEMS; BACTERIA;
D O I
10.3343/alm.2017.37.6.531
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry, with its accuracy and speed, is widely used for bacterial identification. The ASTA MicrolDSys system (ASTA, Korea) was recently developed for species identification. We compared its performance with that of Bruker Biotyper (Bruker Daltonics, Germany). Microbes were recovered from sputum, urine, and pus samples from patients admitted to a tertiary care hospital in Korea from January to April 2016. Matrix solution (alpha-cyano-4-hydroxycinnamic acid) was used, and the peptide profiles acquired from the Microflex LT (Bruker Daltonics) and Tinkerbell LT (ASTA) were analyzed by using their respective software. From 5,322 isolates, Bruker Biotyper identified 163 species; fifty species from 4,919 isolates were identified more than 10 times, including Klebsiella pneumoniae (n = 571), Acinetobacter baumannii (n = 436), Pseudomonas aeruginosa (n = 358), Escherichia coli (n = 372), Staphylococcus aureus (n = 511), S. epidermidis (n = 444), Enterococcus faecium (n = 262), E. faecalis (n = 220), and Candida albicans (n = 248). Identical results, confidence scores (2.0 for Bruker Biotyper), and acceptable scores (>= 140 for ASTA MicrolDSys) were obtained for 86.1% of isolates. Of 4,267 isolates, 99.2% showed acceptable scores in both systems. Results from the ASTA MicrolDSys showed good agreement with those from the Bruker Biotyper. The ASTA MicrolDSys could reliably identify clinically important microorganisms.
引用
收藏
页码:531 / 535
页数:5
相关论文
共 50 条
  • [41] Identification of Cronobacter species by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry with an optimized analysis method
    Wang, Qi
    Zhao, Xiao-Juan
    Wang, Zi-Wei
    Liu, Li
    Wei, Yong-Xin
    Han, Xiao
    Zeng, Jing
    Liao, Wan-Jin
    JOURNAL OF MICROBIOLOGICAL METHODS, 2017, 139 : 172 - 180
  • [42] Species identification of clinical isolates of Bacteroides by matrix-assisted laser-desorption/ionization time-of-flight mass spectrometry
    Nagy, E.
    Maier, T.
    Urban, E.
    Terhes, G.
    Kostrzewa, M.
    CLINICAL MICROBIOLOGY AND INFECTION, 2009, 15 (08) : 796 - 802
  • [43] Matrix-Assisted Laser Desorption Time of Flight Mass Spectrometry
    Wolk, Donna M.
    Clark, Andrew E.
    CLINICS IN LABORATORY MEDICINE, 2018, 38 (03) : 471 - +
  • [44] Detection of solid cobalt species by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry
    Matsumoto, K
    Ajiro, H
    Habaue, S
    Okamoto, Y
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (07) : 730 - 732
  • [45] Evaluation of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry for the discrimination of Lacticaseibacillus species
    Kim, Eiseul
    Yang, Seung-Min
    Cho, Eun-Ji
    Kim, Hae-Yeong
    FOOD MICROBIOLOGY, 2022, 107
  • [47] Evaluation of Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry in Identification of Nontuberculous Mycobacteria
    Marekovic, Ivana
    Bosnjak, Zrinka
    Jakopovic, Marko
    Boras, Zagorka
    Jankovic, Mateja
    Popovic-Grle, Sanja
    CHEMOTHERAPY, 2015, 61 (04) : 167 - 170
  • [48] Matrix-assisted laser desorption-ionization time-of-flight mass spectrometry for the identification of Neisseria gonorrhoeae
    Buchanan, R.
    Ball, D.
    Dolphin, H.
    Dave, J.
    CLINICAL MICROBIOLOGY AND INFECTION, 2016, 22 (09) : 815.e5 - 815.e7
  • [49] Identification of the 'Streptococcus anginosus group' by matrix-assisted laser desorption ionization - time-of-flight mass spectrometry
    Woods, Katherine
    Beighton, David
    Klein, John L.
    JOURNAL OF MEDICAL MICROBIOLOGY, 2014, 63 : 1143 - 1147
  • [50] Comparison of the Bruker Biotyper and Vitek MS Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry Systems for Identification of Mycobacteria Using Simplified Protein Extraction Protocols
    Mather, Cheryl A.
    Rivera, Sheila F.
    Butler-Wu, Susan M.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2014, 52 (01) : 130 - 138