Comparison of a New Matrix-Assisted Laser Desorption/lonization Time-of-Flight Mass Spectrometry Platform, ASTA MicrolDSys, With Bruker Biotyper for Species Identification

被引:14
|
作者
Lee, Yangsoon [1 ]
Sung, Ji Yeon [2 ]
Kim, Hyunsoo [3 ]
Yong, Dongeun [2 ]
Lee, Kyungwon [2 ]
机构
[1] Hanyang Univ, Coll Med, Dept Lab Med, Seoul, South Korea
[2] Yonsei Univ, Coll Med, Res Inst Bacterial Resistance, Dept Lab Med,Severance Hosp, Seoul, South Korea
[3] Natl Police Hosp, Dept Lab Med, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
MicrolDSys; Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry; Bruker Biotyper; DESORPTION IONIZATION-TIME; ROUTINE IDENTIFICATION; MICROFLEX LT; MS; SYSTEMS; BACTERIA;
D O I
10.3343/alm.2017.37.6.531
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry, with its accuracy and speed, is widely used for bacterial identification. The ASTA MicrolDSys system (ASTA, Korea) was recently developed for species identification. We compared its performance with that of Bruker Biotyper (Bruker Daltonics, Germany). Microbes were recovered from sputum, urine, and pus samples from patients admitted to a tertiary care hospital in Korea from January to April 2016. Matrix solution (alpha-cyano-4-hydroxycinnamic acid) was used, and the peptide profiles acquired from the Microflex LT (Bruker Daltonics) and Tinkerbell LT (ASTA) were analyzed by using their respective software. From 5,322 isolates, Bruker Biotyper identified 163 species; fifty species from 4,919 isolates were identified more than 10 times, including Klebsiella pneumoniae (n = 571), Acinetobacter baumannii (n = 436), Pseudomonas aeruginosa (n = 358), Escherichia coli (n = 372), Staphylococcus aureus (n = 511), S. epidermidis (n = 444), Enterococcus faecium (n = 262), E. faecalis (n = 220), and Candida albicans (n = 248). Identical results, confidence scores (2.0 for Bruker Biotyper), and acceptable scores (>= 140 for ASTA MicrolDSys) were obtained for 86.1% of isolates. Of 4,267 isolates, 99.2% showed acceptable scores in both systems. Results from the ASTA MicrolDSys showed good agreement with those from the Bruker Biotyper. The ASTA MicrolDSys could reliably identify clinically important microorganisms.
引用
收藏
页码:531 / 535
页数:5
相关论文
共 50 条
  • [1] Evaluation of the Bruker Biotyper Matrix-Assisted Laser Desorption/lonization Time-of-Flight Mass Spectrometry System for Identification of Clinical and Environmental Isolates of Burkholderia pseudomallei
    Wang, He
    Chen, Ya-Lei
    Teng, Shih-Hua
    Xu, Zhi-Peng
    Xu, Ying-Chun
    Hsueh, Po-Ren
    FRONTIERS IN MICROBIOLOGY, 2016, 7
  • [2] Assessment of a novel matrix-assisted desorption/ionization time-of-flight mass spectrometry platform, asta microidsys, for identification of various acinetobacter species, compared with bruker maldi biotyper
    Kim, W.
    Kim, W.
    Lee, H.
    Park, G.
    Kang, S.
    Youngjin, K.
    Shin, J.
    Won, E.
    Lee, S.
    Kim, C.
    Sookjin, J.
    CLINICA CHIMICA ACTA, 2022, 530 : S311 - S312
  • [3] Evaluation of matrix-assisted laser desorption/ionization-time of flight mass spectrometry, asta microidsys for the identification of anaerobic bacteria: Comparison with bruker biotyper
    Ko, Y. J.
    Kook, J.
    Lim, Y. K.
    Lee, S.
    Kim, C.
    Shin, J. H.
    Kim, S. H.
    Kang, S.
    Park, G.
    Jang, S.
    CLINICA CHIMICA ACTA, 2022, 530 : S312 - S312
  • [4] Evaluation of the Bruker Biotyper Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry System for Identification of Blood Isolates of Vibrio Species
    Cheng, Wern-Cherng
    Jan, I-Shiow
    Chen, Jong-Min
    Teng, Shih-Hua
    Teng, Lee-Jene
    Sheng, Wang-Huei
    Ko, Wen-Chien
    Hsueh, Po-Ren
    JOURNAL OF CLINICAL MICROBIOLOGY, 2015, 53 (05) : 1741 - 1744
  • [5] Evaluation of the Bruker Biotyper Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry System for Identification of Blood Isolates of Acinetobacter Species
    Hsueh, Po-Ren
    Kuo, Lu-Cheng
    Chang, Tsung-Chain
    Lee, Tai-Fen
    Teng, Shih-Hua
    Chuang, Yu-Chung
    Teng, Lee-Jene
    Sheng, Wang-Huei
    JOURNAL OF CLINICAL MICROBIOLOGY, 2014, 52 (08) : 3095 - 3100
  • [6] Comparison of Bruker Biotyper® and Vitek® MS matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry platforms for the identification of filamentous fungi
    Hankins, Julia D.
    Amerson-Brown, Megan H.
    Brown, Cameron A.
    Riegler, Ashleigh N.
    Muldrew, Kenneth L.
    Dunn, James J.
    FUTURE MICROBIOLOGY, 2023, 18 (09) : 553 - 561
  • [7] Utility of the Bruker Biotyper matrix-assisted laser desorption ionisation time-of-flight mass spectrometer in a clinical microbiology laboratory
    Ngan, Grace J. Y.
    Lin, Raymond T. P.
    Teo, Jeanette W. P.
    PATHOLOGY, 2012, 44 (05) : 493 - 496
  • [8] Identification of Weissella species by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry
    Lee, Meng-Rui
    Tsai, Chia-Jung
    Teng, Shih-Hua
    Hsueh, Po-Ren
    FRONTIERS IN MICROBIOLOGY, 2015, 6
  • [9] Evaluation of the matrix-assisted laser desorption/ionization time-of-flight mass spectrometry Bruker Biotyper for identification of Penicillium marneffei, Paecilomyces species, Fusarium solani, Rhizopus species, and Pseudallescheria boydii
    Chen, Ying-Sheng
    Liu, Yen-Hung
    Teng, Shih-Hua
    Liao, Chun-Hsing
    Hung, Chien-Ching
    Sheng, Wang-Huei
    Teng, Lee-Jene
    Hsueh, Po-Ren
    FRONTIERS IN MICROBIOLOGY, 2015, 6
  • [10] Evaluation of the Bruker Biotyper Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry System for Identification of Aspergillus Species Directly from Growth on Solid Agar Media
    Li, Ying
    Wang, He
    Zhao, Yu-Pei
    Xu, Ying-Chun
    Hsueh, Po-Ren
    FRONTIERS IN MICROBIOLOGY, 2017, 8