A Distributed Amplifier System for Bilayer Lipid Membrane (BLM) Arrays With Noise and Individual Offset Cancellation

被引:24
作者
Crescentini, Marco [1 ]
Thei, Frederico [1 ]
Bennati, Marco [2 ]
Saha, Shimul [3 ,4 ]
de Planque, Maurits R. R. [3 ,4 ]
Morgan, Hywel [3 ,4 ]
Tartagni, Marco [1 ]
机构
[1] Univ Bologna, Dept Elect Elect & Informat Engn DEI Guglielmo Ma, I-47521 Cesena, Italy
[2] Univ Bologna, Ctr Ind Res ICT CIRI ICT, I-47521 Cesena, Italy
[3] Univ Southampton, Elect & Comp Sci, Southampton SO17 1BJ, Hants, England
[4] Univ Southampton, Inst Life Sci, Southampton SO17 1BJ, Hants, England
基金
英国工程与自然科学研究理事会;
关键词
Bilayer lipid membrane; current amplifier; discrete-time amplifier; electrophysiology; ion channel recording; low noise; microfluidic device; parallel BLM recording; sensor array; PLATFORM;
D O I
10.1109/TBCAS.2014.2346402
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Lipid bilayer membrane (BLM) arrays are required for high throughput analysis, for example drug screening or advanced DNA sequencing. Complex microfluidic devices are being developed but these are restricted in terms of array size and structure or have integrated electronic sensing with limited noise performance. We present a compact and scalable multichannel electrophysiology platform based on a hybrid approach that combines integrated state-of-the-art microelectronics with low-cost disposable fluidics providing a platform for high-quality parallel single ion channel recording. Specifically, we have developed a new integrated circuit amplifier based on a novel noise cancellation scheme that eliminates flicker noise derived from devices under test and amplifiers. The system is demonstrated through the simultaneous recording of ion channel activity from eight bilayer membranes. The platform is scalable and could be extended to much larger array sizes, limited only by electronic data decimation and communication capabilities.
引用
收藏
页码:334 / 344
页数:11
相关论文
共 34 条
[11]   Circuit techniques for reducing the effects of op-amp imperfections: Autozeroing, correlated double sampling, and chopper stabilization [J].
Enz, CC ;
Temes, GC .
PROCEEDINGS OF THE IEEE, 1996, 84 (11) :1584-1614
[12]  
Haigh D. G., 1983, P IEEE ISCAS
[13]  
Hille B., 2001, Ion channels of Excitable Membranes
[14]   Single molecule measurements within individual membrane-bound ion channels using a polymer-based bilayer lipid membrane chip [J].
Hromada, Louis P. ;
Nablo, Brian J. ;
Kasianowicz, John J. ;
Gaitan, Michael A. ;
DeVoe, Don L. .
LAB ON A CHIP, 2008, 8 (04) :602-608
[15]  
IonFlux System, 2013, HIGH THROUGHP AUT PA
[16]   Automated Parallel Recordings of Topologically Identified Single Ion Channels [J].
Kawano, Ryuji ;
Tsuji, Yutaro ;
Sato, Koji ;
Osaki, Toshihisa ;
Kamiya, Koki ;
Hirano, Minako ;
Ide, Toru ;
Miki, Norihisa ;
Takeuchi, Shoji .
SCIENTIFIC REPORTS, 2013, 3
[17]   Rapid Detection of a Cocaine-Binding Aptamer Using Biological Nanopores on a Chip [J].
Kawano, Ryuji ;
Osaki, Toshihisa ;
Sasaki, Hirotaka ;
Takinoue, Masahiro ;
Yoshizawa, Satoko ;
Takeuchi, Shoji .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2011, 133 (22) :8474-8477
[18]   Noise Analysis and Performance Comparison of Low Current Measurement Systems for Biomedical Applications [J].
Kim, Dongsoo ;
Goldstein, Brian ;
Tang, Wei ;
Sigworth, Fred J. ;
Culurciello, Eugenio .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2013, 7 (01) :52-62
[19]   Single polymer molecules in a protein nanopore in the limit of a strong polymer-pore attraction [J].
Krasilnikov, Oleg V. ;
Rodrigues, Claudio G. ;
Bezrukov, Sergey M. .
PHYSICAL REVIEW LETTERS, 2006, 97 (01)
[20]   Electrical Access to Lipid Bilayer Membrane Microchambers for Transmembrane Analysis [J].
Osaki, Toshihisa ;
Watanabe, Yoshihiko ;
Kawano, Ryuji ;
Sasaki, Hirotaka ;
Takeuchi, Shoji .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2011, 20 (04) :797-799