A Distributed Amplifier System for Bilayer Lipid Membrane (BLM) Arrays With Noise and Individual Offset Cancellation

被引:24
作者
Crescentini, Marco [1 ]
Thei, Frederico [1 ]
Bennati, Marco [2 ]
Saha, Shimul [3 ,4 ]
de Planque, Maurits R. R. [3 ,4 ]
Morgan, Hywel [3 ,4 ]
Tartagni, Marco [1 ]
机构
[1] Univ Bologna, Dept Elect Elect & Informat Engn DEI Guglielmo Ma, I-47521 Cesena, Italy
[2] Univ Bologna, Ctr Ind Res ICT CIRI ICT, I-47521 Cesena, Italy
[3] Univ Southampton, Elect & Comp Sci, Southampton SO17 1BJ, Hants, England
[4] Univ Southampton, Inst Life Sci, Southampton SO17 1BJ, Hants, England
基金
英国工程与自然科学研究理事会;
关键词
Bilayer lipid membrane; current amplifier; discrete-time amplifier; electrophysiology; ion channel recording; low noise; microfluidic device; parallel BLM recording; sensor array; PLATFORM;
D O I
10.1109/TBCAS.2014.2346402
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Lipid bilayer membrane (BLM) arrays are required for high throughput analysis, for example drug screening or advanced DNA sequencing. Complex microfluidic devices are being developed but these are restricted in terms of array size and structure or have integrated electronic sensing with limited noise performance. We present a compact and scalable multichannel electrophysiology platform based on a hybrid approach that combines integrated state-of-the-art microelectronics with low-cost disposable fluidics providing a platform for high-quality parallel single ion channel recording. Specifically, we have developed a new integrated circuit amplifier based on a novel noise cancellation scheme that eliminates flicker noise derived from devices under test and amplifiers. The system is demonstrated through the simultaneous recording of ion channel activity from eight bilayer membranes. The platform is scalable and could be extended to much larger array sizes, limited only by electronic data decimation and communication capabilities.
引用
收藏
页码:334 / 344
页数:11
相关论文
共 34 条
[1]   Formation of artificial lipid bilayers using droplet dielectrophoresis [J].
Aghdaei, Sara ;
Sandison, Mairi E. ;
Zagnoni, Michele ;
Green, Nicolas G. ;
Morgan, Hywel .
LAB ON A CHIP, 2008, 8 (10) :1617-1620
[2]  
[Anonymous], 1999, Axopatch 200B Patch Clamp Theory and Operation Part Number 2500-121 Rev D
[3]  
[Anonymous], 2014, QPATCH AUTOMATED PAT
[4]  
[Anonymous], 2011, TECELLA PICO 2 TECEL
[5]   Nanopore-Based Single-Molecule Mass Spectrometry on a Lipid Membrane Microarray [J].
Baaken, Gerhard ;
Ankri, Norbert ;
Schuler, Anne-Katrin ;
Ruehe, Juergen ;
Behrends, Jan C. .
ACS NANO, 2011, 5 (10) :8080-8088
[6]   Droplet interface bilayers [J].
Bayley, Hagan ;
Cronin, Brid ;
Heron, Andrew ;
Holden, Matthew A. ;
Hwang, William L. ;
Syeda, Ruhma ;
Thompson, James ;
Wallace, Mark .
MOLECULAR BIOSYSTEMS, 2008, 4 (12) :1191-1208
[7]  
Bennati Marco, 2009, 2009 IEEE International Solid-State Circuits Conference (ISSCC 2009), P348, DOI 10.1109/ISSCC.2009.4977451
[8]  
Crescentini M., 2011, 20 EUR C CIRC THEOR
[9]   Noise Limits of CMOS Current Interfaces for Biosensors: A Review [J].
Crescentini, Marco ;
Bennati, Marco ;
Carminati, Marco ;
Tartagni, Marco .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2014, 8 (02) :278-292
[10]   High-throughput electrophysiology: an emerging paradigm for ion-channel screening and physiology [J].
Dunlop, John ;
Bowlby, Mark ;
Peri, Ravikumar ;
Vasilyev, Dmytro ;
Arias, Robert .
NATURE REVIEWS DRUG DISCOVERY, 2008, 7 (04) :358-368