Improving Feedability of Highly Adhesive Active Pharmaceutical Ingredients by Silication

被引:10
作者
Escotet-Espinoza, M. Sebastian [1 ,2 ]
Scicolone, James V. [1 ]
Moghtadernejad, Sara [1 ,3 ]
Sanchez, Eric [4 ]
Cappuyns, Philippe [5 ]
Van Assche, Ivo [5 ]
Di Pretoro, Giustino [6 ]
Ierapetritou, Marianthi [1 ]
Muzzio, Fernando J. [1 ]
机构
[1] Rutgers State Univ, Dept Chem & Biochem Engn, Piscataway, NJ 08854 USA
[2] Merck & Co Inc, Oral Formulat Sci & Technol, Rahway, NJ 07065 USA
[3] Calif State Univ Long Beach, Dept Chem Engn, Long Beach, CA 90840 USA
[4] Janssen Supply Chain, Adv Technol Ctr Excellence, Gurabo, PR USA
[5] Janssen Supply Chain, Adv Technol Ctr Excellence, Beerse, Belgium
[6] Janssen Pharmaceut Companies Johnson & Johnson, Drug Prod Dev Discovery Prod Dev & Supply, Beerse, Belgium
关键词
Continuous pharmaceutical manufacturing; Active pharmaceutical ingredient; Powder feeding; Nano-silica coating; Material properties; CONTINUOUS DIRECT COMPRESSION; POWDER FLOW PROPERTIES; SURFACE-ENERGY; TABLETS; MODEL; FLOWABILITY; PERFORMANCE; HOMOGENEITY; MIXTURES; PLATFORM;
D O I
10.1007/s12247-020-09448-y
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Purpose Loss-in-weight feeders play a vital role in assuring blend and content uniformity as well as lot-to-lot powder traceability in continuous manufacturing. Irregular flow from the feeders propagates through the system, potentially resulting in out-of-specification product. Powder properties such as density, cohesion, and adhesion can cause large variability in the flow rate of ingredients from powder feeders. Feeding of active pharmaceutical ingredients (API) can be difficult because of inherently poor flow, low density, high cohesion, and adhesion. Method API was chosen due to known adhesion behavior inside feeders during continuous operations. The selected APIs were blended with nanosized silica, in a V-blender, to provide separation between the API particles and reducing the effect of interparticle forces. The material was characterized by standard pharmaceutical techniques to identify bulk changes between the as-received and the blended API. The coated API was then fed using a Coperion K-Tron KT-20 pharmaceutical loss-in-weight feeder. The material was dispensed onto a catch scale, recording mass versus time, and analyzed for relative standard deviation and deviation from the set point. Additionally, the mass of the remaining API in the feeder after the run ended was compared between the API and silica-blended API. Results Blending APIs with nanosized silica successfully improved API feeding performance despite their intrinsic highly adhesive and cohesive behavior. Both the pure and silica-blended APIs were fed using a twin screw powder feeder. When feeding unsilicated APIs, large variability in flow rate and screw speed were observed, and large amounts of material coated the inside of the hopper and screws. When the adhesive APIs were blended with nanosized silica and fed through a loss-in-weight feeder, there was significantly less adhesion to the feeder, and the material was dispensed with significant reduction in flow rate and screw speed variability. Conclusions This work provides a means to increase the applicability of continuous manufacturing by enabling the practitioner to manage adverse impact of cohesive material properties on feeder performance. Blending highly adhesive API with silica reduces the adhesion of the API to the feeder hopper and screws, while also improving the deviation in mass flow rate exiting the feeder.
引用
收藏
页码:279 / 292
页数:14
相关论文
共 55 条
[1]   Control Strategies for Drug Product Continuous Direct Compression-State of Control, Product Collection Strategies, and Startup/Shutdown Operations for the Production of Clinical Trial Materials and Commercial Products [J].
Almaya, Ahmad ;
De Belder, Lawrence ;
Meyer, Robert ;
Nagapudi, Karthik ;
Lin, Hung-Ren Homer ;
Leavesley, Ian ;
Jayanth, Jayanthy ;
Bajwa, Gurjit ;
DiNunzio, James ;
Tantuccio, Anthony ;
Blackwood, Dan ;
Abebe, Admassu .
JOURNAL OF PHARMACEUTICAL SCIENCES, 2017, 106 (04) :930-943
[2]   Continuous powder mixing of segregating mixtures under steady and unsteady state regimes: Homogeneity assessment by real-time on-line image analysis [J].
Ammarcha, C. ;
Gatumel, C. ;
Dirion, J. L. ;
Cabassud, M. ;
Berthiaux, H. .
POWDER TECHNOLOGY, 2017, 315 :39-52
[3]   Continuous mixing of powder mixtures with pharmaceutical process constraints [J].
Berthiaux, Henri ;
Marikh, Khadija ;
Gatumel, Cendrine .
CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2008, 47 (12) :2315-2322
[4]   Continuous powder feeding for pharmaceutical solid dosage form manufacture: a short review [J].
Blackshields, Caroline A. ;
Crean, Abina M. .
PHARMACEUTICAL DEVELOPMENT AND TECHNOLOGY, 2018, 23 (06) :554-560
[5]   An integrated approach for dynamic flowsheet modeling and sensitivity analysis of a continuous tablet manufacturing process [J].
Boukouvala, Fani ;
Niotis, Vasilios ;
Ramachandran, Rohit ;
Muzzio, Fernando J. ;
Ierapetritou, Marianthi G. .
COMPUTERS & CHEMICAL ENGINEERING, 2012, 42 :30-47
[6]   Achieving Continuous Manufacturing for Final Dosage Formation: Challenges and How to Meet Them May 20-21, 2014 Continuous Manufacturing Symposium [J].
Byrn, Stephen ;
Futran, Maricio ;
Thomas, Hayden ;
Jayjock, Eric ;
Maron, Nicola ;
Meyer, Robert F. ;
Myerson, Allan S. ;
Thien, Michael P. ;
Trout, Bernhardt L. .
JOURNAL OF PHARMACEUTICAL SCIENCES, 2015, 104 (03) :792-802
[7]   Surface engineered excipients: II. Simultaneous milling and dry coating for preparation of fine-grade microcrystalline cellulose with enhanced properties [J].
Chen, Liang ;
Ding, Xiaoyi ;
He, Zizhou ;
Fan, Siqi ;
Kunnath, Kuriakose T. ;
Zheng, Kai ;
Dave, Rajesh N. .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2018, 546 (1-2) :125-136
[8]   Surface engineered excipients: I. improved functional properties of fine grade microcrystalline cellulose [J].
Chen, Liang ;
Ding, Xiaoyi ;
He, Zizhou ;
Huang, Zhonghui ;
Kunnath, Kuriakose T. ;
Zheng, Kai ;
Dave, Rajesh N. .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2018, 536 (01) :127-137
[9]   On the mechanism of colloidal silica action to improve flow properties of pharmaceutical excipients [J].
Diem Trang Tran ;
Majerova, Diana ;
Vesely, Martin ;
Kulaviak, Lukas ;
Ruzicka, Marek C. ;
Zamostny, Petr .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2019, 556 :383-394
[10]   Loss-in-Weight Feeding Trials Case Study: Pharmaceutical Formulation [J].
Engisch, William E. ;
Muzzio, Fernando J. .
JOURNAL OF PHARMACEUTICAL INNOVATION, 2015, 10 (01) :56-75