A computer model to simulate patellar biomechanics following total knee replacement: the effects of femoral component alignment

被引:57
作者
Heegaard, JH [1 ]
Leyvraz, PF
Hovey, CB
机构
[1] Stanford Univ, Dept Mech Engn, Biomech Engn Div, Stanford, CA 94305 USA
[2] Hop Orthoped Suisse Romande, Lausanne, Switzerland
基金
美国国家科学基金会;
关键词
total knee replacement; patellar button; 3D tracking; contact pressure; femoral component displacement; knee biomechanics; computer modeling;
D O I
10.1016/S0268-0033(01)00020-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. The objective of this study is to analyze the biomechanics of the patellar component following total knee replacement. More specifically we investigated the effect of displacing the femoral component of an Insall-Burstein II total knee replacement on the patellar tracking and patello-femoral contact pressures. Design. We used a validated computer simulation of the knee joint to virtually insert the femoral component with the following four types of placements: (1) no misplacement, (2) 5 degrees of internal rotation, (3) 5 degrees of external rotation and (4) 5 degrees of flexion rotation. The patellar 3D tracking and patello-femoral contact pressures were computed for each femoral component placement as a function of knee flexion angle, Background. Complications at the patello-femoral joint are the among most frequent following total knee replacement. Results. Femoral component placement unevenly affected the associated patellar tracking: a 5 degrees internal rotation tilted and rotated the patella laterally by about 5 degrees throughout knee flexion. A 5 degrees external rotation of the femoral component had less effect on patellar tracking. A rotation of 5 degrees in flexion primarily caused patellar rotation (5-10 degrees lateral rotation). Femoral component malalignment had only minor effects on the peak pressure distributions at the patello-femoral interface. Conclusion. These results suggest that femoral component positioning primarily affects patellar tracking, with a possible threat for patellar subluxation under external rotation of the femoral component.
引用
收藏
页码:415 / 423
页数:9
相关论文
共 29 条
  • [1] A MIXED FORMULATION FOR FRICTIONAL CONTACT PROBLEMS PRONE TO NEWTON LIKE SOLUTION METHODS
    ALART, P
    CURNIER, A
    [J]. COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 1991, 92 (03) : 353 - 375
  • [2] ANOUCHI YS, 1993, CLIN ORTHOP RELAT R, P170
  • [3] Contact areas and pressures between native patellas and prosthetic femoral components
    Benjamin, JB
    Szivek, JA
    Hammond, AS
    Kubchandhani, Z
    Matthews, AI
    Anderson, P
    [J]. JOURNAL OF ARTHROPLASTY, 1998, 13 (06) : 693 - 698
  • [4] Briard JL, 1989, J ARTHROPLASTY S, V4, P87
  • [5] BUECHEL FF, 1991, CLIN ORTHOP RELAT R, P190
  • [6] CAMERON HU, 1982, CLIN ORTHOP RELAT R, P141
  • [7] CURNIER A, 1985, UNILATERAL PROBLEMS, V2, P97
  • [8] A MATHEMATICAL-MODEL FOR THE EVALUATION OF THE BEHAVIOR DURING FLEXION OF CONDYLAR-TYPE KNEE PROSTHESES
    ESSINGER, JR
    LEYVRAZ, PF
    HEEGARD, JH
    ROBERTSON, DD
    [J]. JOURNAL OF BIOMECHANICS, 1989, 22 (11-12) : 1229 - &
  • [9] HASSENPFLUG J, 1989, PATELLOFEMORALGELENK
  • [10] THE BIOMECHANICS OF THE HUMAN PATELLA DURING PASSIVE KNEE FLEXION
    HEEGAARD, J
    LEYVRAZ, PF
    CURNIER, A
    RAKOTOMANANA, L
    HUISKES, R
    [J]. JOURNAL OF BIOMECHANICS, 1995, 28 (11) : 1265 - 1279