Rotational positioning of the tibial tray in total knee arthroplasty: A CT evaluation

被引:25
作者
Berhouet, J. [1 ,2 ]
Beaufils, P. [1 ]
Boisrenoult, P. [1 ]
Frasca, D. [3 ]
Pujol, N. [1 ]
机构
[1] Versailles St Quentin Univ, Andre Mignot Hosp, Versailles Hosp Ctr, Dept Orthopaed & Trauma, F-78157 Le Chesnay, France
[2] Univ Tours, Trousseau Univ Reg Hosp Ctr, Dept Orthopaed & Trauma, F-37170 Chambray Les Tours, France
[3] Univ Poitiers, La Miletrie Univ Hosp Ctr, Dept Anaesthesia & Intens Care, F-86021 Poitiers, France
关键词
Knee; Total knee arthroplasty; Tibial rotation; Computed tomography scanning (CT scanning); Tibial component positioning; FEMORAL COMPONENT; PATELLAR TRACKING; DISTAL FEMUR; ALIGNMENT; AXIS; REPLACEMENT; LANDMARKS; ANATOMY; SCAN;
D O I
10.1016/j.otsr.2011.05.006
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Various surgical techniques have been described to set the rotational alignment of the tibial baseplate during total knee arthroplasty. The self-positioning method ("self-adjustment'') aligns the tibial implant according to the rotational alignment of the femoral component which is used as a reference after performing repeated knee flexion/extension cycles. Postoperative computed tomography scanning produces accurate measurements of the tibial baseplate rotational alignment with respect to the femoral component. Hypothesis: The rotational positioning of the tibial baseplate matches the rotation of the femoral component with parallel alignment to the prosthetic posterior bicondylar axis. Patients and methods: A 3-month follow-up CT scan was carried out after primary total knee arthroplasty implanted in osteoarthritic patients with a mean 7.8 degrees varus deformity of the knee in 50 cases and a mean 8.7 degrees valgus deformity of the knee in 44 cases. The NexGen LPS Flex (Zimmer) fixed-bearing knee prosthesis was used in all cases. An independant examiner (not part of the operating team) measured different variables: the angle between the anatomic transepicondylar axis and the posterior bicondylar axis of the femoral prosthesis (prosthetic posterior condylar angle), the angle between the posterior bicondylar axis and the posterior marginal axis of the tibial prosthesis, the angle between the posterior marginal axis of the tibial prosthesis and the posterior marginal axis of the tibial bone and finally the angle between the anatomic transepicondylar axis and the posterior marginal axis of the tibial prosthesis. Results: For the genu varum and genu valgum subgroups, the mean posterior condylar axis of the femoral prosthesis was 3.1 degrees (SD: 1.91; extremes 0 degrees to 17.5 degrees) and 4.7 degrees (SD: 2.7; extremes 0 degrees to 11 degrees) respectively. The tibial baseplate was placed in external rotation with respect to the femoral component: 0.7 degrees (SD : 4.45; extremes -9.5 degrees to 9.8 degrees) and 0.9 degrees (SD: 4.53; extremes -10.8 degrees to 9.5 degrees), but also to the native tibia: 6.1 degrees (SD: 5.85; extremes -4.6 degrees to 22.5 degrees) and 12.5 degrees (SD: 8.6; extremes -10 degrees to 28.9 degrees). The tibial component was placed in internal rotation relative to the anatomic transepicondylar axis: 1.9 degrees (SD : 4.93; extremes -13.6 degrees to 7 degrees) and 3 degrees (SD : 4.38; extremes -16.2 degrees to 4.8 degrees). Discussion: The tibial component is aligned parallel to the femoral component whatever the initial frontal deformity (P congruent to 0.7). However, a difference was observed between the rotational alignment of the tibial baseplate and the native tibia depending on the initial deformity and could be attributed to the morphological variations of the bony tibial plateau in case of genu valgum. Conclusion: The self-positioning method is a reproducible option when using this type of implant since it allows the tibial component to be positioned parallel to the posterior border of the femur. Level of evidence: Level III. Observational prospective study. (C) 2011 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:699 / 704
页数:6
相关论文
共 50 条
[11]   Evaluation of tibial rotational alignment in total knee arthroplasty: a cadaver study [J].
Roberto Rossi ;
Matteo Bruzzone ;
Davide Edoardo Bonasia ;
Antonio Marmotti ;
Filippo Castoldi .
Knee Surgery, Sports Traumatology, Arthroscopy, 2010, 18 :889-893
[12]   Total Knee Arthroplasty With Asymmetric Femoral Condyles and Tibial Tray [J].
Crockarell, John R., Jr. ;
Hicks, John M. ;
Schroeder, R. Jason ;
Guyton, James L. ;
Harkess, James W. ;
Lavelle, David G. .
JOURNAL OF ARTHROPLASTY, 2010, 25 (01) :108-113
[13]   Rotational malalignment of the femoral and tibial components in total knee arthroplasty [J].
Nagamine, R ;
Whiteside, LA ;
Miura, H ;
Urabe, K ;
Matsuda, S ;
Iwamoto, Y .
JOINT ARTHROPLASTY, 1999, :373-383
[14]   Tibial Rotational Alignment Was Significantly Improved by Use of a CT-Navigated Control Device in Total Knee Arthroplasty [J].
Kuriyama, Shinichi ;
Hyakuna, Katsufumi ;
Inoue, Satoshi ;
Tamaki, Yasuyuki ;
Ito, Hiromu ;
Matsuda, Shuichi .
JOURNAL OF ARTHROPLASTY, 2014, 29 (12) :2352-2356
[15]   The medial border of the tibial tuberosity as an auxiliary tool for tibial component rotational alignment during total knee arthroplasty (TKA) [J].
Drexler, Michael ;
Backstein, David ;
Studler, Ueli ;
Lakstein, Dror ;
Haviv, Barak ;
Schwarzkopf, Ran ;
Rutenberg, Tal Frenkel ;
Warschawski, Yaniv ;
Rath, Ehud ;
Kosashvili, Yona .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (06) :1736-1742
[16]   Effect of tibial tray design on cement morphology in total knee arthroplasty [J].
Ulf J Schlegel ;
Klaus Püschel ;
Michael M Morlock ;
Katrin Nagel .
Journal of Orthopaedic Surgery and Research, 9
[17]   Synchronisation of tibial rotational alignment with femoral component in total knee arthroplasty [J].
Dong-Hoon Lee ;
Jai-Gon Seo ;
Young-Wan Moon .
International Orthopaedics, 2008, 32 :223-227
[18]   Optimal rotational positioning of tibial component in total knee arthroplasty: determined by linker surgical technique using a high definition CT [J].
Woon-Hwa Jung ;
Jai-Gon Seo ;
Dong Hyun Kim ;
Suryamanikanta Balabadra ;
Utkrisht Mandot ;
Dinesh Kumar .
Archives of Orthopaedic and Trauma Surgery, 2020, 140 :401-408
[19]   Evaluation of tibial rotational axis in total knee arthroplasty using magnetic resonance imaging [J].
Nam, Ji-Hoon ;
Koh, Yong-Gon ;
Kim, Paul Shinil ;
Kim, Gihun ;
Kwak, Yoon Hae ;
Kang, Kyoung-Tak .
SCIENTIFIC REPORTS, 2020, 10 (01)
[20]   Total knee arthroplasty: posterior tibial slope influences the size but not the rotational alignment of the tibial component [J].
Ismailidis, Petros ;
Kremo, Valerie ;
Muendermann, Annegret ;
Mueller-Gerbl, Magdalena ;
Nowakowski, Andrej Maria .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2020, 28 (12) :3899-3905