Photonic crystal-based smart contact lens for continuous intraocular pressure monitoring

被引:49
|
作者
Maeng, Bohee [1 ]
Chang, Hyung-kwan [1 ]
Park, Jungyul [1 ]
机构
[1] Sogang Univ, Dept Mech Engn, 35 Baekbeom Ro, Seoul 04107, South Korea
基金
新加坡国家研究基金会;
关键词
GLAUCOMA; SENSOR; CURVATURE; ANGLE; TONOMETRY; THICKNESS; PEOPLE; NUMBER; RABBIT; EYES;
D O I
10.1039/c9lc01268k
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Glaucoma is a very common disease after cataracts and is dangerous enough to cause irreversible blindness. However, often the main symptom of glaucoma is difficult to recognize because it may be absent or appear late, so the risk of blindness is greater. Intraocular pressure (IOP) is a well-known primary factor indicating glaucoma. In this study, we demonstrate a smart IOP sensor embedded in a contact lens that works through visual color changes without an external power source such as a battery or RF-based wireless power transfer. A microhydraulic amplification mechanism is adopted to enhance the range of color change from a photonic crystal (PC)-based flexible membrane whose lattice distance between nanostructures varies according to the morphology changes of an eyeball caused by IOP. The performance of the sensor is quantitatively demonstrated using an artificial silicone eye model for in vitro evaluation and a porcine eyeball for ex vivo verification. It has a limit of detection (LOD) of 3.2 and 5.12 mmHg, which was measured and evaluated using a spectrometer and a smartphone camera, respectively. The results prove that our sensor embedded in the contact lens can continuously monitor the IOP change using color change, and a smartphone camera can be used as a quantitative IOP measurement system in a noninvasive manner without an expensive optical spectrometer.
引用
收藏
页码:1740 / 1750
页数:11
相关论文
共 50 条
  • [31] Temperature Self-Compensating Intelligent Wireless Measuring Contact Lens for Quantitative Intraocular Pressure Monitoring
    Li, Xu
    Chen, Wei
    Li, Hongyang
    Shen, Biwen
    He, Jiangang
    Gao, Huanlin
    Bin, Fengjiao
    Li, Hui
    Xiao, Dengbao
    ACS APPLIED MATERIALS & INTERFACES, 2024, 16 (17) : 22522 - 22531
  • [32] Microfluidic contact lenses for continuous non-invasive intraocular pressure monitoring
    An, Hongbin
    Chen, Liangzhou
    Liu, Xiaojun
    Zhao, Bin
    TENTH INTERNATIONAL SYMPOSIUM ON PRECISION ENGINEERING MEASUREMENTS AND INSTRUMENTATION, 2019, 11053
  • [33] Continuous 24-hour intraocular pressure monitoring in normal Chinese adults using a novel contact lens sensor system
    Zhang, Yuning
    Wei, Yifan
    Lee, Ching Hymn Christopher
    Or, Ping Wai
    Karunaratne, Isuru Kaweendra
    Deng, Mingjie
    Yang, Wenxin
    Chong, Iok Tong
    Yang, Yangfan
    Chen, Zidong
    Fan, Yanmei
    Lam, David C. C.
    Yu, Minbin
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2024,
  • [34] Effect of variations of corneal physiology on novel non-invasive intraocular pressure monitoring soft contact lens
    Angelica Campigotto
    Ankur Ralhan
    Rick Helgason
    Robert J. Campbell
    Yongjun Lai
    Biomedical Microdevices, 2021, 23
  • [35] Evaluation of a Contact Lens-Embedded Sensor for Intraocular Pressure Measurement
    Twa, Michael D.
    Roberts, Cynthia J.
    Karol, Huikai J.
    Mahmoud, Ashraf M.
    Weber, Paul A.
    Small, Robert H.
    JOURNAL OF GLAUCOMA, 2010, 19 (06) : 382 - 390
  • [36] Microfluidic contact lenses for unpowered, continuous and non-invasive intraocular pressure monitoring
    An, Hongbin
    Chen, Liangzhou
    Liu, Xiaojun
    Zhao, Bin
    Zhang, Hong
    Wu, Zhigang
    SENSORS AND ACTUATORS A-PHYSICAL, 2019, 295 : 177 - 187
  • [37] Efficacy of a Contact Lens Sensor for Monitoring 24-H Intraocular Pressure Related Patterns
    Mansouri, Kaweh
    Weinreb, Robert N.
    Liu, John H. K.
    PLOS ONE, 2015, 10 (05):
  • [38] Recent progress of continuous intraocular pressure monitoring
    Xu, Jiandong
    Li, Ruisong
    Xu, Haokai
    Yang, Yi
    Zhang, Sheng
    Ren, Tian-Ling
    NANO SELECT, 2022, 3 (01): : 1 - 19
  • [39] Meeting an unmet need in glaucoma: continuous 24-h monitoring of intraocular pressure
    Mansouri, Kaweh
    Weinreb, Robert N.
    EXPERT REVIEW OF MEDICAL DEVICES, 2012, 9 (03) : 225 - 231
  • [40] Transient changes in refractive error and corneal tomography after 24-h continuous monitoring of intraocular pressure patterns with a contact lens sensor
    Miki, Atsuya
    Kumoi, Miho
    Maeda, Naoyuki
    Koh, Shizuka
    Matsushita, Kenji
    Nishida, Kohji
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2020, 64 (02) : 127 - 133