Photonic crystal-based smart contact lens for continuous intraocular pressure monitoring

被引:49
|
作者
Maeng, Bohee [1 ]
Chang, Hyung-kwan [1 ]
Park, Jungyul [1 ]
机构
[1] Sogang Univ, Dept Mech Engn, 35 Baekbeom Ro, Seoul 04107, South Korea
基金
新加坡国家研究基金会;
关键词
GLAUCOMA; SENSOR; CURVATURE; ANGLE; TONOMETRY; THICKNESS; PEOPLE; NUMBER; RABBIT; EYES;
D O I
10.1039/c9lc01268k
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Glaucoma is a very common disease after cataracts and is dangerous enough to cause irreversible blindness. However, often the main symptom of glaucoma is difficult to recognize because it may be absent or appear late, so the risk of blindness is greater. Intraocular pressure (IOP) is a well-known primary factor indicating glaucoma. In this study, we demonstrate a smart IOP sensor embedded in a contact lens that works through visual color changes without an external power source such as a battery or RF-based wireless power transfer. A microhydraulic amplification mechanism is adopted to enhance the range of color change from a photonic crystal (PC)-based flexible membrane whose lattice distance between nanostructures varies according to the morphology changes of an eyeball caused by IOP. The performance of the sensor is quantitatively demonstrated using an artificial silicone eye model for in vitro evaluation and a porcine eyeball for ex vivo verification. It has a limit of detection (LOD) of 3.2 and 5.12 mmHg, which was measured and evaluated using a spectrometer and a smartphone camera, respectively. The results prove that our sensor embedded in the contact lens can continuously monitor the IOP change using color change, and a smartphone camera can be used as a quantitative IOP measurement system in a noninvasive manner without an expensive optical spectrometer.
引用
收藏
页码:1740 / 1750
页数:11
相关论文
共 50 条
  • [21] Changes in corneal biomechanical properties after 24 hours of continuous intraocular pressure monitoring using a contact lens sensor
    Morales-Fernandez, Laura
    Garcia-Bella, Javier
    Martinez-de-la-Casa, Jose M.
    Sanchez-Jean, Ruben
    Saenz-Frances, Federico
    Arriola-Villalobos, Pedro
    Perucho, Lucia
    Santos-Bueso, Enrique
    Garcia-Feijoo, Julian
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2018, 53 (03): : 236 - 241
  • [22] The importance of and potential for continuous monitoring of intraocular pressure
    McMonnies, Charles W.
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2017, 100 (03) : 203 - 207
  • [23] High-sensitive microfluidic contact lens sensor for intraocular pressure visualized monitoring
    Yuan, Miao
    Liu, Zhiduo
    Wu, Xiaoting
    Gou, Haoyang
    Zhang, Yugui
    Ning, Xin
    Li, Weijun
    Yao, Zhaohui
    Wang, Yijun
    Pei, Weihua
    Chen, Hongda
    SENSORS AND ACTUATORS A-PHYSICAL, 2023, 354
  • [24] A wearable contact lens sensor for noninvasive in-situ monitoring of intraocular pressure
    Fan, Yanyan
    Tu, Hailing
    Zhao, Hongbin
    Wei, Feng
    Yang, Yi
    Ren, Tianling
    NANOTECHNOLOGY, 2021, 32 (09)
  • [25] Notched-ring structured microfluidic contact lens for intraocular pressure monitoring
    Yang, Wentuo
    Zhang, Xiaoshuang
    Wang, Yan
    Fan, Qian
    Zhang, Shuaihua
    Chen, Yongqi
    Shen, Xiaotian
    Xie, Mengying
    Duan, Xuexin
    APPLIED PHYSICS LETTERS, 2021, 119 (19)
  • [26] Continuous 24 h monitoring of changes in intraocular pressure with the wireless contact lens sensor Triggerfish™. First results in patients
    Faschinger, C.
    Mossboeck, G.
    OPHTHALMOLOGE, 2010, 107 (10): : 918 - 922
  • [27] An Ultrasensitive Ti3C2Tx MXene-based Soft Contact Lens for Continuous and Nondestructive Intraocular Pressure Monitoring
    Duan, Zhongyi
    Yuan, Miao
    Liu, Zhiduo
    Pei, Weihua
    Jiang, Kai
    Li, La
    Shen, Guozhen
    SMALL, 2024, 20 (24)
  • [28] Tolerability of 24-Hour Intraocular Pressure Monitoring of a Pressure-sensitive Contact Lens
    Lorenz, Katrin
    Korb, Christina
    Herzog, Nicola
    Vetter, Jan M.
    Elflein, Heike
    Keilani, Munir M.
    Pfeiffer, Norbert
    JOURNAL OF GLAUCOMA, 2013, 22 (04) : 311 - 316
  • [29] Small core FBG-based temperature compensated ‘smart’ contact lens for effective intraocular pressure measurement
    Chen Y.
    Wang J.
    Zhao Y.
    Liu X.-J.
    Zhang H.
    Murdoch I.
    Hull C.
    Barbur J.
    Sun T.
    Grattan K.V.
    Measurement: Sensors, 2019, 1
  • [30] A Piezoresistive-Based Contact Lens for Non-invasive Intraocular Pressure Measurement
    Kumuda, S.
    Gandhi, Uma
    Mangalanathan, Umapathy
    Rajanna, K.
    Pandi, N. Veera
    SENSING AND IMAGING, 2024, 25 (01):