Photonic crystal-based smart contact lens for continuous intraocular pressure monitoring

被引:49
|
作者
Maeng, Bohee [1 ]
Chang, Hyung-kwan [1 ]
Park, Jungyul [1 ]
机构
[1] Sogang Univ, Dept Mech Engn, 35 Baekbeom Ro, Seoul 04107, South Korea
基金
新加坡国家研究基金会;
关键词
GLAUCOMA; SENSOR; CURVATURE; ANGLE; TONOMETRY; THICKNESS; PEOPLE; NUMBER; RABBIT; EYES;
D O I
10.1039/c9lc01268k
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Glaucoma is a very common disease after cataracts and is dangerous enough to cause irreversible blindness. However, often the main symptom of glaucoma is difficult to recognize because it may be absent or appear late, so the risk of blindness is greater. Intraocular pressure (IOP) is a well-known primary factor indicating glaucoma. In this study, we demonstrate a smart IOP sensor embedded in a contact lens that works through visual color changes without an external power source such as a battery or RF-based wireless power transfer. A microhydraulic amplification mechanism is adopted to enhance the range of color change from a photonic crystal (PC)-based flexible membrane whose lattice distance between nanostructures varies according to the morphology changes of an eyeball caused by IOP. The performance of the sensor is quantitatively demonstrated using an artificial silicone eye model for in vitro evaluation and a porcine eyeball for ex vivo verification. It has a limit of detection (LOD) of 3.2 and 5.12 mmHg, which was measured and evaluated using a spectrometer and a smartphone camera, respectively. The results prove that our sensor embedded in the contact lens can continuously monitor the IOP change using color change, and a smartphone camera can be used as a quantitative IOP measurement system in a noninvasive manner without an expensive optical spectrometer.
引用
收藏
页码:1740 / 1750
页数:11
相关论文
共 50 条
  • [1] Non-invasive FBG-based contact lens for continuous intraocular pressure monitoring
    Kumuda, S.
    Uma, G.
    Umapathy, M.
    Anand, V. R.
    Ramanan, S. Raja
    Asokan, S.
    Rajanna, K.
    OPTICAL FIBER TECHNOLOGY, 2024, 84
  • [2] Correlation between corneal and contact lens deformation with changes in intraocular pressure for wearable monitoring systems
    Campigotto, Angelica
    Campbell, Robert J.
    Lai, Yongjun
    EYE, 2023, 37 (10) : 2055 - 2060
  • [3] Intraocular Pressure Monitoring Smart Contact Lens with High Environmental Stability
    Yang, Huan
    Zhu, Hengtian
    Liu, Hanwen
    Mao, Zhengyi
    Luo, Junxian
    Zhu, Shugeng
    Hu, Zizhong
    Yuan, Songtao
    Xu, Fei
    ADVANCED FUNCTIONAL MATERIALS, 2024, 34 (34)
  • [4] Soft wearable contact lens sensor for continuous intraocular pressure monitoring
    Chen, Guo-Zhen
    Chan, Ion-Seng
    Leung, Leo K. K.
    Lam, David C. C.
    MEDICAL ENGINEERING & PHYSICS, 2014, 36 (09) : 1134 - 1139
  • [5] Continuous 24-Hour Monitoring of Intraocular Pressure Patterns With a Contact Lens Sensor
    Mansouri, Kaweh
    Medeiros, Felipe A.
    Tafreshi, Ali
    Weinreb, Robert N.
    ARCHIVES OF OPHTHALMOLOGY, 2012, 130 (12) : 1534 - 1539
  • [6] Hydrogel-Based Smart Contact Lens for Highly Sensitive Wireless Intraocular Pressure Monitoring
    Zhu, Hengtian
    Yang, Huan
    Zhan, Liuwei
    Chen, Ye
    Wang, Junming
    Xu, Fei
    ACS SENSORS, 2022, 7 (10) : 3014 - 3022
  • [7] Prototype of a Nanostructured Sensing Contact Lens for Noninvasive Intraocular Pressure Monitoring
    Sanchez, Irene
    Laukhin, Vladimir
    Moya, Ana
    Martin, Raul
    Ussa, Fernando
    Laukhina, Elena
    Guimera, Anton
    Villa, Rosa
    Rovira, Concepcio
    Aguilo, Jordi
    Veciana, Jaume
    Pastor, Jose C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (11) : 8310 - 8315
  • [8] Wireless theranostic smart contact lens for monitoring and control of intraocular pressure in glaucoma
    Kim, Tae Yeon
    Mok, Jee Won
    Hong, Sang Hoon
    Jeong, Sang Hoon
    Choi, Hyunsik
    Shin, Sangbaie
    Joo, Choun-Ki
    Hahn, Sei Kwang
    NATURE COMMUNICATIONS, 2022, 13 (01)
  • [9] A contact lens promising for non-invasive continuous intraocular pressure monitoring
    Pang, Yu
    Li, Yuxing
    Wang, Xuefeng
    Qi, Chenjie
    Yang, Yi
    Ren, Tian-Ling
    RSC ADVANCES, 2019, 9 (09): : 5076 - 5082
  • [10] Smart Contact Lenses with a Transparent Silver Nanowire Strain Sensor for Continuous Intraocular Pressure Monitoring
    Kim, Tae Yeon
    Shin, Sangbaie
    Choi, Hyunsik
    Jeong, Sang Hoon
    Myung, David
    Hahn, Sei Kwang
    ACS APPLIED BIO MATERIALS, 2021, 4 (05) : 4532 - 4541