Radiation Dose Monitoring for Fluoroscopically Guided Interventional Procedures: Effect on Patient Radiation Exposure

被引:23
作者
Liu, Bob [1 ]
Hirsch, Joshua A. [1 ]
Li, Xinhua [1 ]
Sheridan, Robert M. [1 ]
Rehani, Madan M. [1 ]
Zheng, Hui [3 ]
Rabinov, James D. [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, 55 Fruit St, Boston, MA 02114 USA
[2] Massachusetts Gen Hosp, Dept Neurosurg, 55 Fruit St, Boston, MA 02114 USA
[3] Massachusetts Gen Hosp, Biostat Ctr, 55 Fruit St, Boston, MA 02114 USA
关键词
SKIN INJURIES; GUIDELINES;
D O I
10.1148/radiol.2019180799
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To analyze the clinical effect of continuous dose monitoring and patient follow-up for fluoroscopically guided vascular interventional procedures over 8 years. Materials and Methods: In this retrospective study, an in-house semiautomated system was developed for fluoroscopic dose monitoring. The quarterly number of procedures from January 2010 to December 2017 was analyzed with count time series to estimate quarterly change rate. Technologists recorded four dose surrogates in custom fields of institutional dictation software through a Web interface. Radiation doses were transferred automatically to the radiology report and a centralized dose database when the radiologist initiated procedure dictation. A medical physicist reported weekly on procedures with air kerma at the reference point (K-a,K-r) of 2 Gy or higher to a division-designated radiologist and hospital radiation safety committee who required the attending radiologist to set up follow-up appointments for patients who underwent procedures with a K-a,K-r greater than or equal to 5 Gy. Results: There were a total of 41 585 procedures; 1553 (3.7%) procedures had a K-a,K-r of 2-5 Gy. Among 240 procedures with K-a,K-r greater than 5 Gy, 22 had K-a,K-r greater than 9 Gy. The percentage of high K-a,K-r procedures decreased over time, going from 5.9% in 2010 to 2.0% in 2017 for procedures with K-a,K-r of 2-5 Gy and from 1.0% in 2010 to 0.13% in 2017 for procedures with K-a,K-r greater than or equal to 5 Gy. Relative reduction per quarter was approximately 2.7% (95% confidence interval: 1.5%, 3.8%) for K-a,K-r of 2-5 Gy and 4.5% (95% confidence interval: 1.5%, 7.6%) for K-a,K-r greater than or equal to 5 Gy. Conclusion: Eight-year temporal trends show three-to eightfold reduction in the number of high-dose procedures. (C) RSNA, 2019
引用
收藏
页码:744 / 749
页数:6
相关论文
共 50 条
  • [31] Radiation dose exposure in patients affected by lymphoma undergoing repeat CT examinations: how to manage the radiation dose variability
    Paolicchi, Fabio
    Bastiani, Luca
    Guido, Davide
    Dore, Antonio
    Aringhieri, Giacomo
    Caramella, Davide
    RADIOLOGIA MEDICA, 2018, 123 (03): : 191 - 201
  • [32] Radiation Dose of Interventional Radiology System Using a Flat-Panel Detector
    Chida, Koichi
    Inaba, Yohei
    Saito, Haruo
    Ishibashi, Tadashi
    Takahashi, Shoki
    Kohzuki, Masahiro
    Zuguchi, Masayuki
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (06) : 1680 - 1685
  • [33] Radiation Dose to the Pediatric Cardiac Catheterization and Intervention Patient
    Chida, Koichi
    Ohno, Tadayuki
    Kakizaki, Shuhei
    Takegawa, Mika
    Yuuki, Hiroko
    Nakada, Mitsuru
    Takahashi, Shoki
    Zuguchi, Masayuki
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (05) : 1175 - 1179
  • [34] Retrospective study of patients radiation dose during cardiac catheterization procedures
    Osei, Beverley
    Xu, Lu
    Johnston, Amanda
    Darko, Sara
    Darko, Johnson
    Osei, Ernest
    BRITISH JOURNAL OF RADIOLOGY, 2019, 92 (1099)
  • [35] Evaluation of radiation dose to the lens in interventional cardiology physicians before and after dose limit regulation changes
    Sagehashi, Kodai
    Haga, Yoshihiro
    Takahira, Saki
    Tanabe, Mako
    Nakamura, Mio
    Sota, Masahiro
    Kaga, Yuji
    Abe, Mitsuya
    Tada, Norio
    Chida, Koichi
    JOURNAL OF RADIOLOGICAL PROTECTION, 2024, 44 (03)
  • [36] Monte Carlo-based patient internal dosimetry in fluoroscopy-guided interventional procedures: A review
    Fum, Wilbur K. S.
    Wong, Jeannie Hsiu Ding
    Tan, Li Kuo
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 84 : 228 - 240
  • [37] High-dose radiation exposure and hypothyroidism: aetiology, prevention and replacement therapy
    Reiners, Christoph
    Hanscheid, Heribert
    Schneider, Rita
    JOURNAL OF RADIOLOGICAL PROTECTION, 2021, 41 (04) : R125 - R139
  • [38] DEVELOPMENT OF REAL-TIME RADIATION EXPOSURE DOSIMETRY SYSTEM USING SYNTHETIC RUBY FOR INTERVENTIONAL RADIOLOGY
    Hosokai, Yoshiyuki
    Matsumoto, Kenki
    Kozakai, Masataka
    Takahashi, Kaito
    Usui, Akihito
    Win, Thet Pe
    Muroi, Kenzo
    Saito, Haruo
    RADIATION PROTECTION DOSIMETRY, 2017, 175 (04) : 517 - 522
  • [39] Effect of backscatter radiation on the occupational eye-lens dose
    Ohno, Saya
    Konta, Satoe
    Shindo, Ryota
    Yamamoto, Keisuke
    Isobe, Rio
    Inaba, Yohei
    Suzuki, Masatoshi
    Zuguchi, Masayuki
    Chida, Koichi
    JOURNAL OF RADIATION RESEARCH, 2024, : 450 - 458
  • [40] Fluoroscopically-guided interventions with radiation doses exceeding 5000mGy reference point air kerma: a dosimetric analysis of 89,549 interventional radiology, neurointerventional radiology, vascular surgery, and neurosurgery encounters
    Bundy, Jacob J.
    McCracken, Ian W.
    Shin, David S.
    Monroe, Eric J.
    Johnson, Guy E.
    Ingraham, Christopher R.
    Kanal, Kalpana M.
    Bundy, Richa A.
    Jones, Sean T.
    Valji, Karim
    Chick, Jeffrey Forris Beecham
    CVIR ENDOVASCULAR, 2020, 3 (01)