Novel scatter correction for three-dimensional positron emission tomography by use of a beam stopper device

被引:6
作者
Chuang, KS [1 ]
Wu, J [1 ]
Jan, ML [1 ]
Chen, S [1 ]
Hsu, CH [1 ]
机构
[1] Natl Tsing Hua Univ, Dept Nucl Sci, Hsinchu 30013, Taiwan
关键词
beam stopper; scatter correction; positron emission tomography;
D O I
10.1016/j.nima.2005.06.050
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Modern positron emission tomography scanners generally perform three-dimensional data collection without septa, which increases not only true coincidences but also scattered coincidences. In this study, a beam stopper (BS) device which is made of lead was used to estimate the scatter component in the PET sinogram. Scattered events were then directly measured from those lines of response blocked by stoppers. By assuming that the scatter distribution is a spatially slow-varying function, the scatter component can be recovered using the cubic-spline interpolation from the local measurements. Monte Carlo simulations of an abdomen phantom and the Zubal phantom were performed. Preliminary results demonstrated that the proposed BS method can improve image contrast and quantitative accuracy. Among different configurations, the BS device consisting of twelve lead stoppers with 3 mm radius yielded the optimal result compared to the other BS configurations. This BS method also outperformed the dual-energy window method up to 40% based on the mean squared error. The results indicated that the proposed BS method permits a direct, fast, and accurate scatter correction. (c) 2005 Published by Elsevier B.V.
引用
收藏
页码:540 / 552
页数:13
相关论文
共 34 条
[21]  
Meikle SR, 2003, POSITRON EMISSION TO, P115
[22]   SCATTERED RADIATION IN CHEST RADIOGRAPHY [J].
NIKLASON, LT ;
SORENSON, JA ;
NELSON, JA .
MEDICAL PHYSICS, 1981, 8 (05) :677-681
[23]   Model-based scatter correction for fully 3D PET [J].
Ollinger, JM .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (01) :153-176
[24]   TRIPLE ENERGY WINDOW SCATTER CORRECTION TECHNIQUE IN PET [J].
SHAO, LX ;
FREIFELDER, R ;
KARP, JS .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (04) :641-648
[25]  
Shepp L A, 1982, IEEE Trans Med Imaging, V1, P113, DOI 10.1109/TMI.1982.4307558
[26]   PHYSICAL PERFORMANCE OF A POSITRON TOMOGRAPH FOR BRAIN IMAGING WITH RETRACTABLE SEPTA [J].
SPINKS, TJ ;
JONES, T ;
BAILEY, DL ;
TOWNSEND, DW ;
GROOTOONK, S ;
BLOOMFIELD, PM ;
GILARDI, MC ;
CASEY, ME ;
SIPE, B ;
REED, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (08) :1637-1655
[27]   FULLY 3-DIMENSIONAL RECONSTRUCTION FOR A PET CAMERA WITH RETRACTABLE SEPTA [J].
TOWNSEND, DW ;
GEISSBUHLER, A ;
DEFRISE, M ;
HOFFMAN, EJ ;
SPINKS, TJ ;
BAILEY, DL ;
GILARDI, MC ;
JONES, T .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (04) :505-512
[28]   New, faster, image-based scatter correction for 3D PET [J].
Watson, CC .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (04) :1587-1594
[29]   Evaluation of simulation-based scatter correction for 3-D PET cardiac imaging [J].
Watson, CC ;
Newport, D ;
Casey, ME ;
DeKemp, RA ;
Beanlands, RS ;
Schmand, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (01) :90-97
[30]   Fast implementation of the single scatter simulation algorithm and its use in iterative image reconstruction of PET data [J].
Werling, A ;
Bublitz, O ;
Doll, J ;
Adam, LE ;
Brix, G .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (16) :2947-2960