Novel scatter correction for three-dimensional positron emission tomography by use of a beam stopper device

被引:6
作者
Chuang, KS [1 ]
Wu, J [1 ]
Jan, ML [1 ]
Chen, S [1 ]
Hsu, CH [1 ]
机构
[1] Natl Tsing Hua Univ, Dept Nucl Sci, Hsinchu 30013, Taiwan
关键词
beam stopper; scatter correction; positron emission tomography;
D O I
10.1016/j.nima.2005.06.050
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Modern positron emission tomography scanners generally perform three-dimensional data collection without septa, which increases not only true coincidences but also scattered coincidences. In this study, a beam stopper (BS) device which is made of lead was used to estimate the scatter component in the PET sinogram. Scattered events were then directly measured from those lines of response blocked by stoppers. By assuming that the scatter distribution is a spatially slow-varying function, the scatter component can be recovered using the cubic-spline interpolation from the local measurements. Monte Carlo simulations of an abdomen phantom and the Zubal phantom were performed. Preliminary results demonstrated that the proposed BS method can improve image contrast and quantitative accuracy. Among different configurations, the BS device consisting of twelve lead stoppers with 3 mm radius yielded the optimal result compared to the other BS configurations. This BS method also outperformed the dual-energy window method up to 40% based on the mean squared error. The results indicated that the proposed BS method permits a direct, fast, and accurate scatter correction. (c) 2005 Published by Elsevier B.V.
引用
收藏
页码:540 / 552
页数:13
相关论文
共 34 条
[1]   Optimization of a fully 3D single scatter simulation algorithm for 3D PET [J].
Accorsi, R ;
Adam, LE ;
Werner, ME ;
Karp, JS .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (12) :2577-2598
[2]  
AXELSSON B, 1984, J NUCL MED, V25, P490
[3]   A CONVOLUTION-SUBTRACTION SCATTER CORRECTION METHOD FOR 3D PET [J].
BAILEY, DL ;
MEIKLE, SR .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (03) :411-424
[4]  
Bailey DL, 1998, DEV NUC MED, V32, P55
[5]  
BENTOURKIA M, 1995, J NUCL MED, V36, P121
[6]   EFFECTS OF SCATTER ON MODEL PARAMETER ESTIMATES IN 3D PET STUDIES OF THE HUMAN BRAIN [J].
CHERRY, SR ;
HUANG, SC .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) :1174-1179
[7]  
CHERRY SR, 1993, J NUCL MED, V34, P671
[8]   A hybrid scatter correction for 3D PET based on an estimation of the distribution of unscattered coincidences:: implementation on the ECAT EXACT HR [J].
Ferreira, NC ;
Trébossen, R ;
Lartizien, C ;
Brulon, V ;
Merceron, P ;
Bendriem, B .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (09) :1555-1571
[9]   Correction for scatter in 3D brain PET using a dual energy window method [J].
Grootoonk, S ;
Spinks, TJ ;
Sashin, D ;
Spyrou, NM ;
Jones, T .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (12) :2757-2774
[10]  
HARRISON RL, 1993, IEEE NUCL SCI S