Turn to Turn Fault Detection, Discrimination, and Faulty Region Identification in the Stator and Rotor Windings of Synchronous Machines Based on the Rotational Magnetic Field Distortion

被引:42
作者
Afrandideh, Saeed [1 ]
Milasi, Mostafa Eshaghi [1 ]
Haghjoo, Farhad [1 ]
Cruz, Sergio M. A. [2 ,3 ]
机构
[1] Shahid Beheshti Univ, Abbaspour Sch Engn, Dept Elect Engn, HV MV Devices Protect Res Lab, Tehran 1983969411, Iran
[2] Univ Coimbra, Dept Elect & Comp Engn, P-3030290 Coimbra, Portugal
[3] Inst Telecomunicacoes, P-3030290 Coimbra, Portugal
关键词
Stator windings; Rotors; Voltage measurement; Windings; Magnetic fields; Harmonic analysis; Fault detection; fault region identification; rotational magnetic field; rotor winding; stator windings; synchronous generators; INTERTURN SHORT-CIRCUIT; GENERATOR; DIAGNOSIS; MOTORS; MODEL; INFORMATION; FAILURES;
D O I
10.1109/TEC.2019.2951528
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A flux-based technique is proposed for the on-line detection, localization and discrimination of stator and rotor turn-to-turn faults in synchronous generators, using the measured air-gap rotational magnetic field. Simple magnetic field sensors (MFSs) are installed in the stator slots at different regions, and the corresponding induced voltages are measured. Several differential voltages are then obtained to give a picture of the rotational magnetic field symmetricity, whose distortions indicate the presence of the stator or rotor faults. The proposed diagnostic technique is presented in detail and validated initially by simulation results obtained with a finite element simulation package and afterwards through the experimental tests. The obtained results demonstrate that the proposed technique can be used to detect and discriminate stator and rotor turn-to-turn faults with appropriate sensitivity. In addition, the region of the stator turn-to-turn faults can be identified as well.
引用
收藏
页码:292 / 301
页数:10
相关论文
共 49 条
[31]  
Penman J., 1996, International Conference on Opportunities and Advances in International Power Generation (Conf. Publ. No.419), P137, DOI 10.1049/cp:19960135
[32]  
Reimert D., 2005, PROTECTIVE RELAYING
[33]  
Rodriguez P, 2015, 2015 IEEE 10TH INTERNATIONAL SYMPOSIUM ON DIAGNOSTICS FOR ELECTRIC MACHINES, POWER ELECTRONICS AND DRIVES (SDEMPED), P246, DOI 10.1109/DEMPED.2015.7303697
[34]   DETECTING TURN SHORTS IN ROTOR WINDINGS A new test using magnetic flux monitoring [J].
Sasic, Mladen ;
Stone, Greg C. ;
Stein, Jan ;
Stinson, Chris .
IEEE INDUSTRY APPLICATIONS MAGAZINE, 2013, 19 (02) :63-69
[35]   Finite Element Analysis of Turbine Generator Rotor Winding Shorted Turns [J].
Sasic, Mladen ;
Lloyd, Blake ;
Elez, Ante .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2012, 27 (04) :930-937
[36]   10.1109/TIM.2018.2870265Broken Rotor Bar Detection in Induction Motors Based on Air-Gap Rotational Magnetic Field Measurement [J].
Soleimani, Younes ;
Cruz, Sergio M. A. ;
Haghjoo, Farhad .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2019, 68 (08) :2916-2925
[37]  
Stone GC, 2014, ELECTRICAL INSULATION FOR ROTATING MACHINES: DESIGN, EVALUATION, AGING, TESTING, AND REPAIR, 2ND EDITION, P1, DOI 10.1002/9781118886663
[38]   Application of the zero-sequence voltage component to detect stator winding inter-turn faults in PMSMs [J].
Urresty, Julio-Cesar ;
Riba, Jordi-Roger ;
Romeral, Luis .
ELECTRIC POWER SYSTEMS RESEARCH, 2012, 89 :38-44
[39]   Analysis and Neutral Voltage-Based Detection of Interturn Faults in High-Speed Permanent-Magnet Machines With Parallel Strands [J].
van der Geest, Martin ;
Polinder, Henk ;
Ferreira, Jan Abraham ;
Veltman, Andre ;
Wolmarans, Johan J. ;
Tsiara, Nefeli .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (06) :3862-3873
[40]  
Wan ST, 2005, ICEMS 2005: Proceedings of the Eighth International Conference on Electrical Machines and Systems, Vols 1-3, P2207