CT Pulmonary Angiography Using Automatic Tube Current Modulation Combination with Different Noise Index with Iterative Reconstruction Algorithm in Different Body Mass Index: Image Quality and Radiation Dose

被引:6
|
作者
Zhao, Yong-Xia [1 ]
Zuo, Zi-Wei [1 ]
Suo, Hong-Na [2 ]
Wang, Jia-ning [1 ]
Chang, Jin [3 ]
机构
[1] Affiliated Hosp Hebei Univ, Dept Radiol, 212 Yuhua East Rd Baoding City Hebei Prov, Baoding 071000, Peoples R China
[2] Hebei Univ, Sch Med, Baoding 071000, Peoples R China
[3] Tianjin Univ, Sch Life Sci, Tianjin 300072, Peoples R China
关键词
Automatic tube current modulation; noise index; radiation dose; image quality; CT pulmonary angiography; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; FILTERED BACK-PROJECTION; LOW KILOVOLTAGE SETTINGS; MULTIDETECTOR ROW CT; CHEST CT; CONTRAST ENHANCEMENT; IONIZING-RADIATION; VASCULAR ENHANCEMENT; EXPOSURE; STANDARD;
D O I
10.1016/j.acra.2016.07.018
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: This study aimed to determine the appropriate body mass index (BMI)-dependent noise index (NI) setting in computed tomography pulmonary angiography (CTPA) with automatic tube current modulation with adaptive statistical iterative reconstruction (ASiR). Materials and Methods: A total of 480 patients who had a CTPA were divided into group A (18.5 kg/m(2) <= BMI < 25 kg/m(2)), group B (25 kg/m(2) <= BMI < 30 kg/m(2)), and group C (BMI >= 30 kg/m(2)), according to their BMI values; each group had 160 patients. The three groups were further randomly divided into four subgroups: A1, A2, A3, A4; B1, B2, B3, B4; and Cl, C2, C3, C4, with corresponding NI values of 26, 36, 40, and 46, respectively. All images were restructured with the ASiR algorithm, and the images with the lowest NI (26 Hounsfield units) in each group were used as reference standard. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) for the pulmonary artery of each group were calculated. Subjective image quality was evaluated using a five-score method by two independent radiologists. The CT dose index of volume and dose-length product were recorded and were converted to effective dose (ED). SNR and CNR in the group A, B, and C subgroups were compared to repeated measures analysis of variance, and the subjective score, Volumetric CT dose index of volume, dose-length product, and ED were compared to one-way analysis of variance. Results: For groups A and B, the SNR, CNR, and subjective scores of the images in their subgroups showed no statistical differences (P >.05). The ED in subgroups A4 and B4 was significantly lower than that in subgroups Al (by 33.24%) and B1 (by 34.47%) (P <.01). For group C, there was no significant difference in the SNR, CNR, and the subjective image scores between subgroups C3 and Cl (P >.05). The ED in subgroup C3 was significantly lower than the ED in subgroup Cl (by 47.75%) (P <.01) Conclusions: Patient BMI-dependent NI settings that are higher than the recommended value may be used in CTPA with automatic tube current modulation and ASiR to effectively reduce radiation dose while maintaining diagnostic image quality.
引用
收藏
页码:1513 / 1520
页数:8
相关论文
共 50 条
  • [21] CT angiography of the kidney using routine CT and the latest Gemstone Spectral Imaging combination of different noise indexes: image quality and radiation dose
    Yongxia Zhao
    Yanmin Wu
    Ziwei Zuo
    Shujie Cheng
    La radiologia medica, 2017, 122 : 327 - 336
  • [22] The investigation of dose and image quality of chest computed tomography using different combinations of noise index and adaptive statistic iterative reconstruction level
    Sookpeng, Supawitoo
    Martin, Colin J.
    Butdee, Chitsanupong
    INDIAN JOURNAL OF RADIOLOGY AND IMAGING, 2019, 29 (01): : 53 - 60
  • [23] Effect of iterative reconstruction algorithm levels on noise index and figure-of-merit in CT pulmonary angiography examinations
    Harun, H. H.
    Karim, M. K. A.
    Abbas, Z.
    Sabarudin, A.
    Muniandy, S. C.
    Ibahim, M. J.
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2020, 28 (05) : 893 - 903
  • [24] Iterative Reconstruction Algorithm for Abdominal Multidetector CT at Different Tube Voltages: Assessment of Diagnostic Accuracy, Image Quality, and Radiation Dose in a Phantom Study
    Schindera, Sebastian T.
    Diedrichsen, Lars
    Mueller, Hubert C.
    Rusch, Oliver
    Marin, Daniele
    Schmidt, Bernhard
    Raupach, Rainer
    Vock, Peter
    Szucs-Farkas, Zsolt
    RADIOLOGY, 2011, 260 (02) : 454 - 462
  • [25] Effect of Automatic Tube Current Modulation on Radiation Dose and Image Quality for Low Tube Voltage Multidetector Row CT Angiography: Phantom Study
    Schindera, Sebastian T.
    Nelson, Rendon C.
    Yoshizumi, Terry
    Toncheva, Greta
    Nguyen, Giao
    DeLong, David M.
    Szucs-Farkas, Zsolt
    ACADEMIC RADIOLOGY, 2009, 16 (08) : 997 - 1002
  • [26] The impact of tube current and iterative reconstruction algorithm on dose and image quality of infant CT head examination
    Muhammad, N. A.
    Karim, M. K. A.
    Harun, H. H.
    Rahman, M. A. A.
    Azlan, R. N. R. M.
    Sumardi, N. F.
    RADIATION PHYSICS AND CHEMISTRY, 2022, 200
  • [27] Ultra-low dose CT colonography with automatic tube current modulation and sinogram-affirmed iterative reconstruction: Effects on radiation exposure and image quality
    Cianci, Roberta
    Pizzi, Andrea Delli
    Esposito, Gianliugi
    Timpani, Mauro
    Tavoletta, Alessandra
    Pulsone, Pierluigi
    Basilico, Raffaella
    Cotroneo, Antonio Raffaele
    Filippone, Antonella
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (01): : 321 - 330
  • [28] Pediatric cardiovascular CT angiography: Radiation dose reduction using automatic anatomic tube current modulation
    Herzog, Christopher
    Mulvihill, Denise M.
    Nguyen, Shaun A.
    Savino, Giancarlo
    Schmidt, Bernhard
    Costello, Philip
    Vogl, Thomas J.
    Schoepf, U. Joseph
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (05) : 1232 - 1240
  • [29] Improved image quality and low radiation dose with hybrid iterative reconstruction with 80 kV CT pulmonary angiography
    Laqmani, Azien
    Regier, Marc
    Veldhoen, Simon
    Backhaus, Alexandra
    Wassenberg, Felicia
    Sehner, Susanne
    Groth, Michael
    Nagel, Hans-Dieter
    Adam, Gerhard
    Henes, Frank O.
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (10) : 1962 - 1969
  • [30] Implementing a coronary CT angiography protocol based on the body mass index: radiation dose reduction, image quality, and diagnostic performance
    Cuellar-Calabria, H.
    Burceta, G.
    Juarez-Garcia, M. S.
    Reyes-Juareza, J. L.
    Pizzib, M. N.
    Aguade-Bruixc, S.
    Roquea, A.
    RADIOLOGIA, 2024, 66 (01): : 2 - 12