Comparison of three-view thoracic radiography and computed tomography for detection of pulmonary nodules in dogs with neoplasia

被引:77
作者
Armbrust, Laura J. [1 ]
Biller, David S. [1 ]
Bamford, Aubrey [1 ]
Chun, Ruthanne [1 ]
Garrett, Laura D. [1 ]
Sanderson, Michael W. [1 ]
机构
[1] Kansas State Univ, Coll Vet Med, Dept Clin Sci, Manhattan, KS 66502 USA
来源
JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION | 2012年 / 240卷 / 09期
关键词
PRIMARY LUNG-TUMORS; THIN-SECTION; HELICAL CT; METASTASES; HEMANGIOSARCOMA; OSTEOSARCOMA; MANAGEMENT; DISEASE; IMAGES;
D O I
10.2460/javma.240.9.1088
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective-To compare the detection of pulmonary nodules by use of 3-view thoracic radiography and CT in dogs with confirmed neoplasia. Design-Prospective case series. Animals-33 dogs of various breeds. Procedures-3 interpreters independently evaluated 3-view thoracic radiography images. The location and size of pulmonary nodules were recorded. Computed tomographic scans of the thorax were obtained and evaluated by a single interpreter. The location, size, margin, internal architecture, and density of pulmonary nodules were recorded. Sensitivity, specificity, positive predictive value, and negative predictive value were calculated for thoracic radiography (with CT as the gold standard). Results-21 of 33 (64%) dogs had pulmonary nodules or masses detected on CT. Of the dogs that had positive CT findings, 17 of 21 (81%) had pulmonary nodules or masses detected on radiographs by at least 1 interpreter. Sensitivity of radiography ranged from 71% to 95%, and specificity ranged from 67% to 92%. Radiography had a positive predictive value of 83% to 94% and a negative predictive value of 65% to 89%. The 4 dogs that were negative for nodules on thoracic radiography but positive on CT were all large-breed to giant-breed dogs with osteosarcoma. Conclusions and Clinical Relevance-CT was more sensitive than radiography for detection of pulmonary nodules. This was particularly evident in large-breed to giant-breed dogs. Thoracic CT is recommended in large-breed to giant-breed dogs with osteosarcoma if the detection of pulmonary nodules will change treatment. (J Am Vet Med Assoc 2012;240:1088-1094)
引用
收藏
页码:1088 / 1094
页数:7
相关论文
共 35 条
  • [31] A cloud-based computer-aided detection system improves identification of lung nodules on computed tomography scans of patients with extra-thoracic malignancies
    Vassallo, Lorenzo
    Traverso, Alberto
    Agnello, Michelangelo
    Bracco, Christian
    Campanella, Delia
    Chiara, Gabriele
    Fantacci, Maria Evelina
    Torres, Ernesto Lopez
    Manca, Antonio
    Saletta, Marco
    Giannini, Valentina
    Mazzetti, Simone
    Stasi, Michele
    Cerello, Piergiorgio
    Regge, Daniele
    EUROPEAN RADIOLOGY, 2019, 29 (01) : 144 - 152
  • [32] A cloud-based computer-aided detection system improves identification of lung nodules on computed tomography scans of patients with extra-thoracic malignancies
    Lorenzo Vassallo
    Alberto Traverso
    Michelangelo Agnello
    Christian Bracco
    Delia Campanella
    Gabriele Chiara
    Maria Evelina Fantacci
    Ernesto Lopez Torres
    Antonio Manca
    Marco Saletta
    Valentina Giannini
    Simone Mazzetti
    Michele Stasi
    Piergiorgio Cerello
    Daniele Regge
    European Radiology, 2019, 29 : 144 - 152
  • [33] Comparison of Chest Dual-energy Subtraction Digital Tomosynthesis and Dual-energy Subtraction Radiography for Detection of Pulmonary Nodules: Initial Evaluations in Human Clinical Cases
    Gomi, Tsutomu
    Nozaki, Miwako
    Takeda, Tohoru
    Umeda, Tokuo
    Takahashi, Kazutoshi
    Nakajima, Masahiro
    ACADEMIC RADIOLOGY, 2013, 20 (11) : 1357 - 1363
  • [34] Improved detection of air-filled lesions using computed tomography in dogs with recurrent spontaneous pneumothorax through reduction of pulmonary atelectasis via positive pressure ventilation
    Toshima, Atsushi
    Fulkerson, Caroline V.
    Kagawa, Yumiko
    Murakami, Masahiro
    FRONTIERS IN VETERINARY SCIENCE, 2024, 11
  • [35] Lung nodule detection performance in five observers on computed tomography (CT) with adaptive iterative dose reduction using three-dimensional processing (AIDR 3D) in a Japanese multicenter study: Comparison between ultra-low-dose CT and low-dose CT by receiver-operating characteristic analysis
    Nagatani, Yukihiro
    Takahashi, Masashi
    Murata, Kiyoshi
    Ikeda, Mitsuru
    Yamashiro, Tsuneo
    Miyara, Tetsuhiro
    Koyama, Hisanobu
    Koyama, Mitsuhiro
    Sato, Yukihisa
    Moriya, Hiroshi
    Noma, Satoshi
    Tomiyama, Noriyuki
    Ohno, Yoshiharu
    Murayama, Sadayuki
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (07) : 1401 - 1412