B1+ Phase mapping at 7 T and its application for in vivo electrical conductivity mapping

被引:125
作者
van Lier, Astrid L. H. M. W. [1 ]
Brunner, David O. [2 ,3 ]
Pruessmann, Klaas P. [2 ,3 ]
Klomp, Dennis W. J. [1 ]
Luijten, Peter R. [1 ]
Lagendijk, Jan J. W. [1 ]
van den Berg, Cornelis A. T. [1 ]
机构
[1] Univ Med Ctr Utrecht, Imaging Div, NL-3584 CX Utrecht, Netherlands
[2] Univ Zurich, Inst Biomed Engn, Zurich, Switzerland
[3] ETH, Zurich, Switzerland
关键词
electrical conductivity; dielectric properties; B?1+phase; high field MRI; BIRDCAGE COIL; HIGH-FIELD; RESONANCE; POLARIZATION; SYSTEM; MRI; SAR;
D O I
10.1002/mrm.22995
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this study, a new approach to measure local electrical conductivity in tissue is presented, which is based on the propagating B?1+ phase and the homogeneous Helmholtz equation. This new MRI technique might open future opportunities for tumor and lesion characterization based on conductivity differences, while it may also find application in radio frequency safety assessment. Prerequisites for conductivity mapping using only the B?1+ phase (instead of the complex B?+1 field) are addressed. Furthermore it was found that the B?1+ phase can be derived directly from the measurable transceive phase arg(B?+1 B?-1) in the head. Validation for a human head excited by a 7 T-birdcage coil using simulations and measurements showed that it is possible to measure in vivo conductivity patterns in the brain using B?1+ phase information only. Conductivity contrast between different brain tissues is clearly observed. The measured mean values for white matter, gray matter and cerebrospinal fluid differed 54%, 26%, and -13% respectively from literature values. The proposed method for B?1+ phase measurements is very suited for in vivo applications, as the measurement is short (less than a minute per imaged slice) and exposes the patient to low RF power, contrary to earlier proposed approaches. Magn Reson Med, 2012. (C) 2011 Wiley Periodicals, Inc.
引用
收藏
页码:552 / 561
页数:10
相关论文
共 33 条
[1]  
[Anonymous], 2004, HDB MRI PULSE SEQUEN, DOI 10.1016/B978-0-12-092861-3.X5000-6
[2]   B1+ Interferometry for the Calibration of RF Transmitter Arrays [J].
Brunner, David O. ;
Pruessmann, Klaas P. .
MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (06) :1480-1488
[3]   SAR and B1 field distributions in a heterogeneous human head model within a birdcage coil [J].
Collins, CM ;
Li, SZ ;
Smith, MB .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (06) :847-856
[4]   Central brightening due to constructive interference with, without, and despite dielectric resonance [J].
Collins, CM ;
Liu, WZ ;
Schreiber, W ;
Yang, QX ;
Smith, MB .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (02) :192-196
[5]   Saturated double-angle method for rapid B1 plus mapping [J].
Cunningham, Charles H. ;
Pauly, John M. ;
Nayak, Krishna S. .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (06) :1326-1333
[6]  
DUENSING R, 2005, Patent No. 6865494
[7]   Dielectric properties of biological tissue: Variation with age [J].
Gabriel, C .
BIOELECTROMAGNETICS, 2005, :S12-S18
[8]   COMPARISON OF LINEAR AND CIRCULAR-POLARIZATION FOR MAGNETIC-RESONANCE IMAGING [J].
GLOVER, GH ;
HAYES, CE ;
PELC, NJ ;
EDELSTEIN, WA ;
MUELLER, OM ;
HART, HR ;
HARDY, CJ ;
ODONNELL, M ;
BARBER, WD .
JOURNAL OF MAGNETIC RESONANCE, 1985, 64 (02) :255-270
[9]   Magnetic induction tomography - A measuring system for biological tissues [J].
Griffiths, H ;
Stewart, WR ;
Gough, W .
ELECTRICAL BIOIMPEDANCE METHODS: APPLICATIONS TO MEDICINE AND BIOTECHNOLOGY, 1999, 873 :335-345
[10]   AUTOMATIC, LOCALIZED INVIVO ADJUSTMENT OF ALL 1ST-ORDER AND 2ND-ORDER SHIM COILS [J].
GRUETTER, R .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (06) :804-811