Color duplex ultrasound and contrast-enhanced ultrasound in comparison to MS-CT in the detection of endoleak following endovascular aneurysm repair

被引:54
作者
Clevert, D. -A. [1 ,2 ]
Minaifar, N. [1 ]
Weckbach, S. [1 ]
Kopp, R.
Meimarakis, G.
Clevert, D. -A. [1 ,2 ]
Reiser, M. [1 ]
机构
[1] Univ Munich, Univ Hosp Grosshadern, Dept Clin Radiol, D-81377 Munich, Germany
[2] Charite Univ Med Berlin, Med Clin Nephrol & Internal Intens Care, Berlin, Germany
关键词
endoleak; contrast enhanced ultrasound; MS-CT; color duplex ultrasound; ABDOMINAL AORTIC-ANEURYSMS; COMPUTED-TOMOGRAPHY; ENDOLUMINAL REPAIR; STENT-GRAFTS; SURVEILLANCE;
D O I
10.3233/CH-2008-1075
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to compare Color Duplex Ultrasound (CDU), Contrast-Enhanced Ultrasound (CEUS) and Multislice Computed Tomography (MS-CT) angiography in the routine follow up of patients following Endovascular Repair (EVAR) of Abdominal Aortic Aneurysm ( AAA). 43 consecutive patients with AAA underwent endovascular aneurysm repair and were imaged with CDU, CEUS and MS-CT angiography at regular intervals after the procedure. Each imaging modality was evaluated for the detection of endoleaks. The presence of endoleaks was analyzed and the conspicuity of findings was assessed. CTA was used as gold standard in determining the presence of endoleaks. CDU was true positive for endoleaks in 5/43 patients (11.6%) and false positive for endoleaks in 2/43 patients (4.6%). The sensitivity of CDU was therefore 33.3% and its specificity 92.8%; the positive and negative predictive values were 0.71 and 0.72, respectively. CEUS was true positive for the detection of endoleaks in 15/43 patients (34.9%) and false positive in 2/43 patients ( 4.6%). The sensitivity of CEUS was therefore 100% and its specificity 93%; the positive and negative predictive values were 0.88 and 1. In the follow up the two false positive endoleaks in CEUS were confirmed as true positive endoleaks by CEUS and MS-CT. In our small patient group, contrast-enhanced ultrasound seemed to be more accurately in demonstrating endoleaks after EVAR than MS-CT angiography and may be considered as a primary surveillance modality whereas duplex ultrasound scanning alone is not as sensitive as CEUS and MS-CT angiography in detection of endoleaks. Especially in patients with contraindications for CT contrast agents ( e. g. due to renal failure or severe allergy) CEUS provides a good alternative to MS-CT.
引用
收藏
页码:121 / 132
页数:12
相关论文
共 22 条
  • [1] Computed tomography versus color duplex ultrasound for surveillance of abdominal aortic Stent-Grafts
    AbuRahma, AF
    Welch, CA
    Mullins, BB
    Dyer, B
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2005, 12 (05) : 568 - 573
  • [2] Type II lumbar endoleaks: Hemodynamic differentiation by contrast-enhanced ultrasound scanning and influence on aneurysm enlargement after endovascular aneurysm repair
    Bargellini, I
    Napoli, V
    Petruzzi, P
    Cioni, R
    Vignali, C
    Sardella, SG
    Ferrari, M
    Bartolozzi, C
    [J]. JOURNAL OF VASCULAR SURGERY, 2005, 41 (01) : 10 - 18
  • [3] Comparison of contrast-enhanced ultrasound and computed tomography in classifying endoleaks after endovascular treatment of abdominal aorta aneurysms:: Preliminary experience
    Carrafiello, Gianpaolo
    Lagana, Domenico
    Recaldini, Chiara
    Mangini, Monica
    Bertolotti, Elena
    Caronno, Roberto
    Tozzi, Matteo
    Piffaretti, Gabriele
    Genovese, Eugenio Annibale
    Fugazzola, Carlo
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 29 (06) : 969 - 974
  • [4] CLEVERT DA, IMAGING ENDOLEAKS EN
  • [5] Endovascular stent-graft in abdominal aortic aneurysms: The relationship between patent vessels that arise from the aneurysmal sac and early endoleak
    Fan, CM
    Rafferty, EA
    Geller, SC
    Kaufman, JA
    Brewster, DC
    Cambria, RP
    Waltman, AC
    [J]. RADIOLOGY, 2001, 218 (01) : 176 - 182
  • [6] Giannoni MF, 2003, J ENDOVASC THER, V10, P208, DOI 10.1583/1545-1550(2003)010<0208:CUIFAS>2.0.CO
  • [7] 2
  • [8] Fate of endoleaks after endoluminal repair of abdominal aortic aneurysms with the EVT® device
    Makaroun, M
    Zajko, A
    Sugimoto, H
    Eskandari, M
    Webster, M
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1999, 18 (03) : 185 - 190
  • [9] Clinical consequences of periprosthetic leak after endovascular repair of abdominal aortic aneurysm
    Matsumura, JS
    Moore, WS
    [J]. JOURNAL OF VASCULAR SURGERY, 1998, 27 (04) : 606 - 613
  • [10] Abdominal aortic aneurysm: Contrast-enhanced US for missed endoleaks after endoluminal repair
    Napoli, V
    Bargellini, I
    Sardella, SG
    Petruzzi, P
    Cioni, R
    Vignali, C
    Ferrari, M
    Bartolozzi, C
    [J]. RADIOLOGY, 2004, 233 (01) : 217 - 225