Prospective electrocardiography-triggered CT angiography of the great thoracic vessels in infants and toddlers with congenital heart disease: Feasibility and image quality

被引:43
作者
Pache, Gregor [1 ]
Grohmann, Jochen [2 ]
Bulla, Stefan [1 ]
Arnold, Raoul [2 ]
Stiller, Brigitte [2 ]
Schlensak, Christian [3 ]
Langer, Mathias [1 ]
Blanke, Philipp [1 ]
机构
[1] Univ Hosp Freiburg, Dept Diagnost Radiol, D-79104 Freiburg, Germany
[2] Univ Hosp Freiburg, Dept Pediat Cardiol, D-79104 Freiburg, Germany
[3] Univ Hosp Freiburg, Dept Cardiovasc Surg, D-79104 Freiburg, Germany
关键词
Congenital heart disease; Children; Computed tomography angiography; CHILDREN; REDUCTION; AORTA;
D O I
10.1016/j.ejrad.2011.01.032
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate feasibility and image quality and to calculate radiation dose estimates for computed tomography angiography (CTA) of the great thoracic vessels in infants and toddlers with congenital heart disease (CHD) using end-systolic prospective electrocardiography-triggered sequential dual-source data acquisition. Methods: This study was institutional review board approved; informed consent was obtained. Twenty children (age 1.2 +/- 1.1 years) underwent 22 prospective ECG-triggered sequential dual-source CTA examinations (Somatom Definition, Siemens) with tube current (250 mAs/rot) centered at 250 ms past the R-peak in the cardiac cycle (end-systole). Tube voltage was set to 80 kV. Image quality was evaluated by two readers independently using a four-point grading scale (4 = excellent, 1 = non-diagnostic). Radiation dose estimates were calculated from the dose-length-product (DLP). Results: All CT images showed diagnostic image quality (mean score 3.67 +/- 0.67, kappa = 0.85). Stair-step artifacts were present in one and breathing artifacts in 4 patients, with neither impairing diagnostic image quality. Mean heart rate (bpm) was 107.6 +/- 12.1 (76-130), mean heart rate variability (bpm) was 2.5 +/- 2.0 (1-9). Mean scan length (mm) was 90.7 +/- 22.7 (50-134). Mean estimated effective dose was 0.32 +/- 0.11 mSv. Conclusion: Prospective ECG-triggered sequential dual source CTA is feasible in infants and toddlers with CHD, thereby allowing almost motion-free imaging of the great thoracic vessels with the benefit of a low radiation dose. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:E440 / E445
页数:6
相关论文
共 20 条
[11]   APPLICATION OF HIERARCHICAL KAPPA-TYPE STATISTICS IN ASSESSMENT OF MAJORITY AGREEMENT AMONG MULTIPLE OBSERVERS [J].
LANDIS, JR ;
KOCH, GG .
BIOMETRICS, 1977, 33 (02) :363-374
[12]   Pre- and postoperative evaluation of congenital heart disease in children and adults with 64-section CT [J].
Leschka, Sebastian ;
Oechslin, Erwin ;
Husmann, Lars ;
Desbiolles, Lotus ;
Marincek, Borut ;
Genoni, Michele ;
Pretre, Rene ;
Jenni, Rolf ;
Wildermuth, Simon ;
Alkadhi, Hatem .
RADIOGRAPHICS, 2007, 27 (03) :829-846
[13]   Abdominal CT with low tube voltage: Preliminary observations about radiation dose, contrast enhancement, image quality, and noise [J].
Nakayama, Y ;
Awai, K ;
Funama, Y ;
Hatemura, M ;
Imuta, M ;
Nakaura, T ;
Ryu, D ;
Morishita, S ;
Sultana, S ;
Sato, N ;
Yamashita, Y .
RADIOLOGY, 2005, 237 (03) :945-951
[14]   Multidetector CT for congenital heart patients: what a paediatric radiologist should know [J].
Paul, Jean-Francois ;
Rohnean, Adela ;
Sigal-Cinqualbre, Anne .
PEDIATRIC RADIOLOGY, 2010, 40 (06) :869-875
[15]   Relationship between noise, dose, and pitch in cardiac multi-detector row CT [J].
Primak, Andrew N. ;
McCollough, Cynthia H. ;
Bruesewitz, Michael R. ;
Zhang, Jie ;
Fletcher, Joel G. .
RADIOGRAPHICS, 2006, 26 (06) :1785-1794
[16]   Thoracic aorta: Motion artifact reduction with retrospective and prospective electrocardiography-assisted multi-detector row CT [J].
Roos, JE ;
Willmann, JK ;
Weishaupt, D ;
Lachat, M ;
Marincek, B ;
Hilfiker, PR .
RADIOLOGY, 2002, 222 (01) :271-277
[17]   Surgically corrected congenital heart disease: Utility of 64-MDCT [J].
Spevak, Philip J. ;
Johnson, Pamela T. ;
Fishman, Elliot K. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (03) :854-861
[18]   Dual-source CT in step-and-shoot mode: Noninvasive coronary angiography with low radiation dose [J].
Stolzmann, Paul ;
Leschka, Sebastian ;
Scheffel, Hans ;
Krauss, Tobias ;
Desbiolles, Lotus ;
Plass, Andre ;
Genoni, Michele ;
Flohr, Thomas G. ;
Wildermuth, Simon ;
Marincek, Borut ;
Alkadhi, Hatem .
RADIOLOGY, 2008, 249 (01) :71-80
[19]   Age-specific effective doses for pediatric MSCT examinations at a large children's hospital using DLP conversion coefficients: a simple estimation method [J].
Thomas, Karen E. ;
Wang, Bo .
PEDIATRIC RADIOLOGY, 2008, 38 (06) :645-656
[20]   RELATIONSHIPS BETWEEN LEFT VENTRICULAR EJECTION TIME, STROKE VOLUME, AND HEART RATE IN NORMAL INDIVIDUALS AND PATIENTS WITH CARDIOVASCULAR DISEASE [J].
WEISSLER, AM ;
PEELER, RG ;
ROEHLL, WH .
AMERICAN HEART JOURNAL, 1961, 62 (03) :367-&