Comparison of the Primary Stability of Porous Tantalum and Titanium Acetabular Revision Constructs

被引:11
作者
Beckmann, Nicholas A. [1 ,2 ]
Bitsch, Rudi G. [3 ]
Schonhoff, Mareike [4 ]
Siebenrock, Klaus-Arno [2 ]
Schwarze, Martin [1 ]
Jaeger, Sebastian [4 ]
机构
[1] Heidelberg Univ Hosp, Clin Orthoped & Trauma Surg, D-69118 Heidelberg, Germany
[2] Bern Univ Hosp, Inselspital, Dept Orthopaed Surg & Traumatol, CH-3010 Bern, Switzerland
[3] Natl Joint Ctr, ATOS Clin, D-69115 Heidelberg, Germany
[4] Heidelberg Univ Hosp, Lab Biomech & Implant Res, Clin Orthoped & Trauma Surg, D-69118 Heidelberg, Germany
关键词
porous implants; tantalum; titanium; acetabulum; hip arthroplasty; hip replacement; revision hip arthroplasty; acetabular revision; primary stability; TOTAL HIP-ARTHROPLASTY; TRABECULAR METAL; BONE INGROWTH; CUPS; AUGMENTS; RECONSTRUCTION; MICROMOTION; COMPONENTS; DEFECTS;
D O I
10.3390/ma13071783
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Adequate primary stability of the acetabular revision construct is necessary for long-term implant survival. The difference in primary stability between tantalum and titanium components is unclear. Six composite hemipelvises with an acetabular defect were implanted with a tantalum augment and cup, using cement fixation between cup and augment. Relative motion was measured at cup/bone, cup/augment and bone/augment interfaces at three load levels; the results were compared to the relative motion measured at the same interfaces of a titanium cup/augment construct of identical dimensions, also implanted into composite bone. The implants showed little relative motion at all load levels between the augment and cup. At the bone/augment and bone/cup interfaces the titanium implants showed less relative motion than tantalum at 30% load (p < 0.001), but more relative motion at 50% (p = n.s.) and 100% (p < 0001) load. The load did not have a significant effect at the augment/cup interface (p = 0.086); it did have a significant effect on relative motion of both implant materials at bone/cup and bone/augment interfaces (p < 0.001). All interfaces of both constructs displayed relative motion that should permit osseointegration. Tantalum, however, may provide a greater degree of primary stability at higher loads than titanium. The clinical implication is yet to be seen
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Mechanical Stability of Novel Highly Porous Metal Acetabular Components in Revision Total Hip Arthroplasty
    Meneghini, R. Michael
    Meyer, Christopher
    Buckley, Christine A.
    Hanssen, Arlen D.
    Lewallen, David G.
    [J]. JOURNAL OF ARTHROPLASTY, 2010, 25 (03) : 337 - 341
  • [22] Use of Oversized Highly Porous Cups in Acetabular Revision
    Ranawat, Amar S.
    Meftah, Morteza
    Thomas, Anil O.
    Thippanna, Rajshekhar K.
    Ranawat, Chitranjan S.
    [J]. ORTHOPEDICS, 2016, 39 (02) : E301 - E306
  • [23] Long-term results of combined porous tantalum augments and titanium-coated cups for Paprosky type III bone defects in acetabular revision
    Xiao, Qiang
    Xu, Bing
    Zhou, Kai
    Ling, Tingxian
    Yuan, Mingcheng
    Pei, Fuxing
    Zhou, Zongke
    [J]. INTERNATIONAL ORTHOPAEDICS, 2021, 45 (07) : 1699 - 1706
  • [24] The Use of Porous Tantalum Augments for the Reconstruction of Acetabular Defect in Primary Total Hip Arthroplasty
    Ling, Ting-Xian
    Li, Jin-Long
    Zhou, Kai
    Xiao, Qiang
    Pei, Fu-Xing
    Zhou, Zong-Ke
    [J]. JOURNAL OF ARTHROPLASTY, 2018, 33 (02) : 453 - 459
  • [25] Inferior extended fixation utilizing porous titanium augments improves primary anti-rotational stability of the acetabular component
    Tang, Hao
    Zhou, Baochun
    Huang, Yong
    Zhou, Yixin
    Chen, Bo
    Li, Xinyu
    [J]. CLINICAL BIOMECHANICS, 2019, 70 : 158 - 163
  • [26] Minimum 2-Year Outcomes of a Novel 3D-printed Fully Porous Titanium Acetabular Shell in Revision Total Hip Arthroplasty
    Berlinberg, Elyse J.
    Kavian, J. Abraham
    Roof, Mackenzie A.
    Shichman, Ittai
    Frykberg, Brett
    Lutes, William B.
    Schnaser, Erik A.
    Jones, Stephen A.
    Mccalden, Richard W.
    Schwarzkopf, Ran
    [J]. ARTHROPLASTY TODAY, 2022, 18 : 39 - 44
  • [27] Porous tantalum shells and augments for acetabular cup revisions
    Moličnik A.
    Hanc M.
    Rečnik G.
    Krajnc Z.
    Rupreht M.
    Fokter S.K.
    [J]. European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (6) : 911 - 917
  • [28] Highly Porous Titanium Acetabular Components in Primary and Revision Total Hip Arthroplasty: A Systematic Review
    Malahias, Michael-Alexander
    Kostretzis, Lazaros
    Greenberg, Alex
    Nikolaou, Vasileios S.
    Atrey, Amit
    Sculco, Peter K.
    [J]. JOURNAL OF ARTHROPLASTY, 2020, 35 (06) : 1737 - 1749
  • [29] Highly Porous Tantalum Acetabular Components Without Ancillary Screws Have Similar Migration to Porous Titanium Acetabular Components With Screws at 2 Years: A Randomized Controlled Trial
    Howie, Donald W.
    Holubowycz, Oksana T.
    Callary, Stuart A.
    Robertson, Thomas S.
    Solomon, Lucian B.
    [J]. JOURNAL OF ARTHROPLASTY, 2020, 35 (10) : 2931 - 2937
  • [30] Porous Tantalum and Titanium in Orthopedics: A Review
    Han, Qing
    Wang, Chenyu
    Chen, Hao
    Zhao, Xue
    Wang, Jincheng
    [J]. ACS BIOMATERIALS SCIENCE & ENGINEERING, 2019, 5 (11) : 5798 - 5824