Reproducibility assessment of commercial optically stimulated luminescence system in diagnostic X-ray beams

被引:7
作者
Musa, Yahaya [1 ,2 ]
Hashim, Suhairul [1 ,3 ]
Bradley, David A. [4 ,5 ]
Karim, Muhammad Khalis A. [6 ]
Hashim, Asmaliza [7 ]
机构
[1] UTM, Dept Phys, Fac Sci, Skudai 81310, Johor, Malaysia
[2] Ahmadu Bello Univ, Ctr Energy Res & Training, PMB 1014, Zaria, Nigeria
[3] UTM, ISI SIR, Ctr Sustainable Nanomat CSNano, Skudai 81310, Johor, Malaysia
[4] Univ Surrey, Fac Engn & Phys Sci, Dept Phys, Guildford, Surrey, England
[5] Sunway Univ, Inst Healthcare Dev, Petaling Jaya 46150, Selangor, Malaysia
[6] Univ Putra Malaysia, Dept Phys, Serdang 43400, Selangor Darul, Malaysia
[7] Agensi Nuklear Malaysia, Med Phys Div, Selangor 4300, Malaysia
关键词
Reproducibility; NanoDots; OSLD; RQR; Depletion; OSL TECHNIQUE; DOSIMETRY; RADIOTHERAPY; NANODOT; CT;
D O I
10.1007/s10967-017-5571-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study investigates the reproducibility of commercial optically stimulated luminescence (OSL) system at different X-ray beams in general radiography. The reader stability was evaluated at first and found to be within the accepted tolerance level of +/- 10%. Henceforth, reproducibility of OSL dosimeters due to repeated readouts after single exposure were found to be between 1.0% (80 kV/20 mGy) and 5.9% (80 kV/10 mAs), while reproducibility in repeated irradiation of optically stimulated luminescence dosimeters (OSLDs) from the same batch (80 kV/8 mGy) was between 1.8 and 4.3%. After multiple readouts of OSLD, the OSL signal decreased by approximately - 0.4% per readout and - 5.4% per 10 sequential readouts. The reproducibility response demonstrates the suitability of the nanoDots OSLD for use in radiography.
引用
收藏
页码:2029 / 2036
页数:8
相关论文
共 25 条
  • [11] Changes in optically stimulated luminescent dosimeter (OSLD) dosimetric characteristics with accumulated dose
    Jursinic, Paul A.
    [J]. MEDICAL PHYSICS, 2010, 37 (01) : 132 - 140
  • [12] Landauer, 2012, INLIGHT MICROSTAR SY
  • [13] Performance of optically stimulated luminescence Al2O3 dosimeter for low doses of diagnostic energy X-rays
    Lim, Chang Seon
    Lee, Sang Bock
    Jin, Gye Hwan
    [J]. APPLIED RADIATION AND ISOTOPES, 2011, 69 (10) : 1486 - 1489
  • [14] McKeever SWS, 2003, RADIAT PROT DOSIM, V104, P263, DOI 10.1093/oxfordjournals.rpd.a006191
  • [15] Ministry of Health Malaysia, 2013, MAL DIAGN REF LEV ME
  • [16] Optically stimulated luminescence in vivo dosimetry for radiotherapy: physical characterization and clinical measurements in 60Co beams
    Mrcela, I.
    Bokulie, T.
    Izewska, J.
    Budanec, M.
    Froebe, A.
    Kusic, Z.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (18) : 6065 - 6082
  • [17] Application of the OSL technique for beta dosimetry
    Pinto, T. N. O.
    Cecatti, S. G. P.
    Gronchi, C. C.
    Caldas, L. V. E.
    [J]. RADIATION MEASUREMENTS, 2008, 43 (2-6) : 332 - 334
  • [18] Characterization of the nanoDot OSLD dosimeter in CT
    Scarboro, Sarah B.
    Cody, Dianna
    Alvarez, Paola
    Followill, David
    Court, Laurence
    Stingo, Francesco C.
    Zhang, Di
    McNitt-Gray, Michael
    Kry, Stephen F.
    [J]. MEDICAL PHYSICS, 2015, 42 (04) : 1797 - 1807
  • [19] Radiation dose measurements of an on-board imager X-ray unit using optically-stimulated luminescence dosimeters
    Smith, Leon
    Haque, Mamoon
    Morales, Johnny
    Hill, Robin
    [J]. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2015, 38 (04) : 665 - 669
  • [20] Tawfik G, 2013, WORLD C MED PHYS BIO, V39, P1195