The Accuracy of Intraoperative O-arm Images for the Assessment of Pedicle Screw Postion

被引:70
作者
Santos, Edward R. G. [1 ]
Ledonio, Charles G. [1 ]
Castro, Carlos A. [1 ]
Truong, Walter H. [1 ]
Sembrano, Jonathan N. [1 ]
机构
[1] Univ Minnesota, Dept Orthopaed, Minneapolis, MN 55454 USA
关键词
intraoperative imaging; pedicle screws; screw revision; COMPUTED-TOMOGRAPHY; PLACEMENT; FIXATION; COMPLICATIONS; RELIABILITY; AGREEMENT;
D O I
10.1097/BRS.0b013e3182257cae
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Human cadaveric study. Objective. The objective of the study was to determine the accuracy of intraoperative O-arm images in determining pedicle screw position using open dissection as the gold standard. Summary of Background Data. Pedicle screws are widely used in the treatment of various spinal disorders. Postoperative computed tomographic scans are the imaging gold standard to detect pedicle screw malposition. However, a second procedure is necessary if such malpositioned screws have to be revised. The O-arm is an intraoperative scanner that allows revision of a screw without having to return the patient to the operating room for a separate procedure. No previous studies have looked at the accuracy of intraoperative O-arm images in determining pedicle screw position. Methods. This factorial validation study utilized 9 cadavers in a comparison of intraoperative O-arm images and the dissection gold standard. Four hundred sixteen screws were inserted using 3-dimensional image (O-arm) guidance from C2 to S1. The screw positions were randomized into 3 groups: "IN" (fully contained within the pedicle), "OUT-lateral," or "OUT-medial." After screw insertion, O-arm images were obtained and reviewed in a blinded fashion by 3 independent observers. Dissection identified the true position of the screws. Specificity, sensitivity, positive predictive value (PPV), and negative predictive value (NPV) were calculated using dissection results as the gold standard. The interobserver reliability was also determined. Results. The overall accuracy, specificity, sensitivity, PPV, and NPV of O-arm images for the thoracic and lumbar spine were 73%, 76%, 71%, 74%, and 72%, respectively. Accuracy of surgeon perception in the cervical spine was significantly less than in the thoracic and lumbosacral spine. There was substantial interobserver agreement between the 3 readers. Conclusion. Intraoperative O-arm images accurately detect significant pedicle screw violations in the thoracic and lumbosacral spine but are less accurate for the cervical spine.
引用
收藏
页码:E119 / E125
页数:7
相关论文
共 13 条
[1]   Imaging assessment of lumbar pedicle screw placement - Sensitivity and specificity of plain radiographs and computer axial tomography [J].
Brooks, Dahari ;
Eskander, Mark ;
Balsis, Steve ;
Ordway, Nat ;
Connolly, Patrick .
SPINE, 2007, 32 (13) :1450-1453
[2]   COMPLICATIONS OF LUMBAR SPINAL-FUSION WITH TRANSPEDICULAR INSTRUMENTATION [J].
DAVNE, SH ;
MYERS, DL .
SPINE, 1992, 17 (06) :S184-S189
[3]   COMPLICATIONS ASSOCIATED WITH THE TECHNIQUE OF PEDICLE SCREW FIXATION - A SELECTED SURVEY OF ABS MEMBERS [J].
ESSES, SI ;
SACHS, BL ;
DREYZIN, V .
SPINE, 1993, 18 (15) :2231-2239
[4]   Reliability of roentgenogram evaluation of pedicle screw position [J].
Ferrick, MR ;
Kowalski, JM ;
Simmons, ED .
SPINE, 1997, 22 (11) :1249-1252
[5]   The use of pedicle-screw internal fixation for the operative treatment of spinal disorders [J].
Gaines, RW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (10) :1458-1476
[6]   Accuracy of pedicle screw insertion: A prospective CT study in 30 low back patients [J].
Laine T. ;
Mäkitalo K. ;
Schlenzka D. ;
Tallroth K. ;
Poussa M. ;
Alho A. .
European Spine Journal, 1997, 6 (6) :402-405
[7]   MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA [J].
LANDIS, JR ;
KOCH, GG .
BIOMETRICS, 1977, 33 (01) :159-174
[8]   APPLICATION OF HIERARCHICAL KAPPA-TYPE STATISTICS IN ASSESSMENT OF MAJORITY AGREEMENT AMONG MULTIPLE OBSERVERS [J].
LANDIS, JR ;
KOCH, GG .
BIOMETRICS, 1977, 33 (02) :363-374
[9]   Assessment of pedicle screw placement utilizing conventional radiography and computed tomography: A proposed systematic approach to improve accuracy of interpretation [J].
Learch, TJ ;
Massie, JB ;
Pathria, MN ;
Ahlgren, BA ;
Garfin, SR .
SPINE, 2004, 29 (07) :767-773
[10]   Esophageal injury from thoracic pedicle screw placement in a polytrauma patient - A case report and literature review [J].
O'Brien, J. R. ;
Krushinski, E. ;
Zai-Ro, C. M. ;
Sciadini, M. ;
Gelb, D. ;
Ludwig, S. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2006, 20 (06) :431-434