Comparison of gradient encoding schemes for diffusion-tensor MRI

被引:255
作者
Hasan, KM [1 ]
Parker, DL [1 ]
Alexander, AL [1 ]
机构
[1] Univ Utah, Dept Phys, Salt Lake City, UT 84112 USA
关键词
diffusion tensor; icosahedron; encoding optimization; heuristic polyhedra; numerically optimized polyhedra; regular polyhedra;
D O I
10.1002/jmri.1107
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The accuracy of single diffusion tensor MRI (DT-MRI) measurements depends upon the encoding scheme used. In this study, the diffusion tensor accuracy of several strategies for DT-MRI encoding are compared. The encoding strategies are based upon heuristic, numerically optimized, and regular polyhedra schemes. The criteria or numerical optimization include the minimum tensor variance (MV), minimum force (MF), minimum potential energy (ME), and minimum condition number. The regular polyhedra scheme includes variations of the icosahedron. Analytical comparisons and Monte Carlo simulations show that the icosahedron scheme is optimum for six encoding directions. The MV, AW, and ME solutions for six directions are functionally equivalent to the icosahedron scheme. Two commonly used heuristic DT-MRI encoding schemes with six directions, which are based upon the geometric landmarks of a cube (vertices, edge centers, and face centers), are found to be suboptimal. For more than six encoding directions, many methods are able to generate a set of equivalent optimum encoding directions including the regular polyhedra, and the ME, Aff and MV numerical optimization solutions. For seven directions, a previously described heuristic encoding scheme (tetrahedral plus x, y, z) was also found to be optimum. This study Indicates that there is no significant advantage to using more than six encoding directions as long as an optimum encoding is used for six directions. Future DT-MRI studies are necessary to validate these observations. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:769 / 780
页数:12
相关论文
共 41 条
[1]   AN IMPROVED NUCLEAR-MAGNETIC-RESONANCE DIFFUSION-COEFFICIENT IMAGING METHOD USING AN OPTIMIZED PULSE SEQUENCE [J].
AHN, CB ;
LEE, SY ;
NALCIOGLU, O ;
CHO, ZH .
MEDICAL PHYSICS, 1986, 13 (06) :789-793
[2]   2-DIMENSIONAL CHEMICAL-SHIFT TENSOR CORRELATION SPECTROSCOPY - ANALYSIS OF SENSITIVITY AND OPTIMAL MEASUREMENT DIRECTIONS [J].
ALDERMAN, DW ;
SHERWOOD, MH ;
GRANT, DM .
JOURNAL OF MAGNETIC RESONANCE, 1990, 86 (01) :60-69
[3]  
ALEXANDER AL, 2000, P 8 ANN M ISMRM DENV, P781
[4]  
ARMITAGE PA, 1999, P 7 ANN M ISMRM PHIL, P1797
[5]   A simplified method to measure the diffusion tensor from seven MR images [J].
Basser, PJ ;
Pierpaoli, C .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (06) :928-934
[6]   Inferring microstructural features and the physiological state of tissues from diffusion-weighted images [J].
Basser, PJ .
NMR IN BIOMEDICINE, 1995, 8 (7-8) :333-344
[7]   A theoretical study of the effect of experimental noise on the measurement of anisotropy in diffusion imaging [J].
Bastin, ME ;
Armitage, PA ;
Marshall, I .
MAGNETIC RESONANCE IMAGING, 1998, 16 (07) :773-785
[8]  
CHUNG F, 1993, AM SCI, V81, P56
[9]   Encoding of anisotropic diffusion with tetrahedral gradients: A general mathematical diffusion formalism and experimental results [J].
Conturo, TE ;
McKinstry, RC ;
Akbudak, E ;
Robinson, BH .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (03) :399-412
[10]   Diffusion MRI: Precision, accuracy and flow effects [J].
Conturo, TE ;
McKinstry, RC ;
Aronovitz, JA ;
Neil, JJ .
NMR IN BIOMEDICINE, 1995, 8 (7-8) :307-332