Use of personal protective equipment and operating boom behaviors in four surgical subspecialties: Personal protective equipment and behaviors in surgery

被引:39
作者
Akduman, D
Kim, LE
Parks, RL
L'Ecuyer, PB
Mutha, S
Jeffe, DB
Evanoff, BA
Fraser, VJ
机构
[1] Washington Univ, Sch Med, Dept Internal Med, Div Infect Dis, St Louis, MO 63110 USA
[2] Gazi Univ, Fac Med, Dept Infect Dis, Ankara, Turkey
[3] Washington Univ, Sch Med, Dept Med, Div Gen Med Sci, St Louis, MO 63110 USA
[4] Washington Univ, Sch Med, Div Hlth Behav Res, St Louis, MO 63130 USA
关键词
D O I
10.1086/501601
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
OBJECTIVE: To evaluate Universal Precautions (UP) compliance in the operating room (OR). DESIGN: Prospective observational cohort. Trained observers recorded information about (1) personal protective equipment used by OR staff; (2) eyewear, glove, or gown breaks; (3) the nature of sharps transfers; (4) risk-taking behaviors of the OR staff; and (5) needlestick injuries and other blood and bodyfluid exposures. SETTING: Barnes-Jewish Hospital, a 1,000-bed, tertiary-care hospital affiliated with Washington University School of Medicine, St Louis, Missouri. PARTICIPANTS: OR personnel in four surgical specialties (gynecologic, orthopedic, cardiothoracic, and general). Procedures eligible for the study were selected randomly Hand surgery and procedures requiring no or a very small incision (eg, arthroscopy, laparoscopy) were excluded. RESULTS: A total of 597 healthcare workers' procedures were observed in 76 surgical cases (200 hours). Of the 597 healthcare workers, 32% wore regular glasses, and 24% used no eye protection. Scrub nurses and medical students were more likely than other healthcare workers to wear goggles. Only 28% of healthcare workers double gloved, with orthopedic surgery personnel being the most compliant. Sharps passages were not announced in 91% of the surgical procedures. In 65 cases (86%), sharps were adjusted manually Three percutaneous and 14 cutaneous exposures occurred, for a total exposure rate of 22%. CONCLUSION: OR personnel had poor compliance with UP. Although there was significant variation in use of personal protective equipment between groups, the total exposure rate was high (22%), indicating the need for further training and reinforcement of UP to reduce occupational exposures (Infect Control Hosp Epidemiol 1999;20:110-114).
引用
收藏
页码:110 / 114
页数:5
相关论文
共 21 条
[1]  
[Anonymous], 1990, MMWR Recomm Rep, V39, P1
[2]  
[Anonymous], 1987, MMWR-MORBID MORTAL W
[3]   COMPLIANCE WITH UNIVERSAL PRECAUTIONS IN A UNIVERSITY HOSPITAL EMERGENCY DEPARTMENT [J].
BARAFF, LJ ;
TALAN, DA .
ANNALS OF EMERGENCY MEDICINE, 1989, 18 (06) :654-657
[4]  
*CDCP, 1997, HIV AIDS SURV REP, V7, P15
[5]  
Centers for Disease Control, 1988, MMWR Morb Mortal Wkly Rep, V37, P377
[6]   RISK OF EXPOSURE OF SURGICAL PERSONNEL TO PATIENTS BLOOD DURING SURGERY AT SAN-FRANCISCO-GENERAL-HOSPITAL [J].
GERBERDING, JL ;
LITTELL, C ;
TARKINGTON, A ;
BROWN, A ;
SCHECTER, WP .
NEW ENGLAND JOURNAL OF MEDICINE, 1990, 322 (25) :1788-1793
[7]   A COMPARISON OF OBSERVED AND SELF-REPORTED COMPLIANCE WITH UNIVERSAL PRECAUTIONS AMONG EMERGENCY DEPARTMENT PERSONNEL AT A MINNESOTA PUBLIC TEACHING HOSPITAL - IMPLICATIONS FOR ASSESSING INFECTION CONTROL PROGRAMS [J].
HENRY, K ;
CAMPBELL, S ;
MAKI, M .
ANNALS OF EMERGENCY MEDICINE, 1992, 21 (08) :941-946
[8]   THE RISK OF OCCUPATIONAL HUMAN-IMMUNODEFICIENCY-VIRUS INFECTION IN HEALTH-CARE WORKERS - ITALIAN MULTICENTER STUDY [J].
IPPOLITO, G ;
PURO, V ;
DECARLI, G .
ARCHIVES OF INTERNAL MEDICINE, 1993, 153 (12) :1451-1458
[9]   HEPATITIS-B AND HEPATITIS-C IN EMERGENCY DEPARTMENT PATIENTS [J].
KELEN, GD ;
GREEN, GB ;
PURCELL, RH ;
CHAN, DW ;
QAQISH, BF ;
SIVERTSON, KT ;
QUINN, TC .
NEW ENGLAND JOURNAL OF MEDICINE, 1992, 326 (21) :1399-1404
[10]  
KELEN GD, 1990, J ACQ IMMUN DEF SYND, V3, P987