Numerical and experimental study on the influence of top bypass flow on the performance of plate fin heat exchanger

被引:17
作者
Cai, Huikun [1 ]
Su, Lijun [1 ]
Liao, Yidai [1 ]
Weng, Zeju [1 ]
机构
[1] Xiamen Univ, Dept Mech & Elect Engn, Room 263 Aerosp Engn Bldg, Xiamen 361102, Fujian, Peoples R China
关键词
Plate-fin heat exchanger; Top bypass flow; Thermal performance analysis; Height ratio of top bypass flow duct to fin; Optimized frontal area ratio; SINKS;
D O I
10.1016/j.applthermaleng.2018.10.007
中图分类号
O414.1 [热力学];
学科分类号
摘要
Bypass flow deserves a deep research as it is the important phenomenon in plate-fin heat exchanger and is of great influence on the thermal performance. Present studies had consulted this problem, but did not conduct a throughout study and restricted in a limited geometry. Therefore, in this paper an experimental bench is built for the research. Numerical simulations are also carried out on the models with and without bypass flow. The discrepancy of average heat transfer coefficient in simulation with bypass flow increases with air velocity and the maximum difference reaches 82.76% at the velocity of 10 m/s when compared to the model without that, but reduces to be 19.1% when compared to experimental results. After experimental validation, top bypass flow is analyzed with different ratios of top duct height to fin height and varied air velocities. A relationship between air velocity and its minimum height ratio is gained for the estimation in initial design of plate-fin heat exchanger. The optimization with varied fin numbers and interval distances is also carried out, and it is found that the optimized ratio of frontal fin area to frontal plate-fin heat exchanger area is almost keeping at an approximate value of 0.5 for all cases, but thinner fin and narrower air flowing channel can make better heat transfer effect. This paper reveals the influence of top bypass flow on thermal performance and design principle of plate-fin heat exchanger, which is hopeful to be an instruction for its future application in many fields.
引用
收藏
页码:356 / 363
页数:8
相关论文
共 22 条
  • [1] AZAR K, 1992, EIGHTH ANNUAL IEEE SEMICONDUCTOR THERMAL MEASUREMENT AND MANAGEMENT SYMPOSIUM, P12, DOI 10.1109/STHERM.1992.172847
  • [2] BUTTERBAUGH MA, 1995, ADV ELECT PACKAGING, V10, P843
  • [3] Cai Hui-kun, 2017, Journal of South China University of Technology (Natural Science Edition), V45, P91, DOI 10.3969/j.issn.1000-565X.2017.02.013
  • [4] Chapman C.L., 1994, P 1994 IEEE CPMT 10
  • [5] Experiments and modeling of the hydraulic resistance and heat transfer of in-line square pin fin heat sinks with top by-pass flow
    Dogruoz, MB
    Urdaneta, M
    Ortega, A
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2005, 48 (23-24) : 5058 - 5071
  • [6] NARROW CHANNEL FORCED AIR HEAT SINK
    GOLDBERG, N
    [J]. IEEE TRANSACTIONS ON COMPONENTS HYBRIDS AND MANUFACTURING TECHNOLOGY, 1984, 7 (01): : 154 - 159
  • [7] Performance evaluation of counter flow heat exchangers considering the effect of heat in leak and longitudinal conduction for low-temperature applications
    Gupta, P
    Atrey, MD
    [J]. CRYOGENICS, 2000, 40 (07) : 469 - 474
  • [8] Hao Guo, 2016, REFRIG AIR CONDITION, V16, P11
  • [9] Hossain J. Rakib, 2007, ANN IEEE SEM THER ME, DOI [10.1109/STHERM.2007.352427, DOI 10.1109/STHERM.2007.352427]
  • [10] Modeling of the thermal and hydraulic performance of plate fin, strip fin, and pin fin heat sinks - Influence of flow bypass
    Jonsson, H
    Moshfegh, B
    [J]. IEEE TRANSACTIONS ON COMPONENTS AND PACKAGING TECHNOLOGIES, 2001, 24 (02): : 142 - 149