Gas transfer performance of a hollow fiber silicone membrane oxygenator:: Ex vivo study

被引:13
作者
Kawahito, S
Maeda, T
Takano, T
Nonaka, K
Linneweber, J
Mikami, M
Motomura, T
Ichikawa, S
Glueck, J
Sato, K
Kuwana, J
Nosé, Y
机构
[1] Baylor Coll Med, Michael E DeBakey Dept Surg, Houston, TX 77030 USA
[2] Fuji Syst Inc, Tokyo, Japan
关键词
hollow fiber; silicone membrane; oxygenator; pediatric; cardiopulmonary bypass; extracorporeal membrane oxygenation;
D O I
10.1046/j.1525-1594.2001.06706-4.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Based on the results of in vitro studies of many experimental models, a silicone hollow fiber membrane oxygenator for pediatric cardiopulmonary bypass (CPB) and extracorporeal membrane oxygenation (ECMO) was developed using an ultrathin silicone hollow fiber with a 300 mum outer diameter and a wall thickness of 50 mum. In this study, we evaluated the gas transfer performance of this oxygenator simulating pediatric CPB and ECMO conditions. Two ex vivo studies in a pediatric CPB condition for 6 h and 5 ex vivo studies in an ECMO condition for 1 week were performed with venoarterial bypass using healthy calves. At a blood flow rate of 2 L/min and V/Q = 4 (V = gas flow rate, Q = blood flow rate) (pediatric CPB condition), the O-2 and CO2 gas transfer rates were maintained at 97.44 +/- 8.88 (mean +/- SD) and 43.59 +/- 15.75 ml/min/m(2), respectively. At a blood flow rate of 1 L/min and V/Q = 4 (ECMO condition), the O-2 and CO2 gas transfer rates were maintained at 56.15 +/- 8.49 and 42.47 +/- 9.22 ml/min/m(2), respectively. These data suggest that this preclinical silicone membrane hollow fiber oxygenator may be acceptable for both pediatric CPB and long-term ECMO use.
引用
收藏
页码:498 / 502
页数:5
相关论文
共 9 条
[1]   Development of a membrane oxygenator for ECMO using a novel fine silicone hollow fiber [J].
Funakubo, A ;
Higami, T ;
Sakuma, I ;
Fukui, Y ;
Kawamura, T ;
Sato, K ;
Sueoka, A ;
Nose, Y .
ASAIO JOURNAL, 1996, 42 (05) :M837-M840
[2]  
KOLOBOW T, 1971, ASAIO T, V17, P350
[3]   Preclinical evaluation of a hollow fiber silicone membrane oxygenator for extracorporeal membrane oxygenator application [J].
Maeda, T ;
Iwasaki, A ;
Kawahito, S ;
Nakata, K ;
Nonaka, K ;
Linneweber, J ;
Shulte-Eistrup, S ;
Takano, T ;
Yoshikawa, M ;
Sato, K ;
Kuwana, J ;
Murabayashi, S ;
Nosé, Y .
ASAIO JOURNAL, 2000, 46 (04) :426-430
[4]  
Montoya J P, 1992, ASAIO J, V38, pM399, DOI 10.1097/00002480-199207000-00064
[5]  
Mottaghy K, 1989, ASAIO Trans, V35, P640
[6]  
Niimi Y, 1997, ASAIO J, V43, pM706
[7]  
Niimi Y, 1997, ARTIF ORGANS, V21, P1082
[8]   Development of an antithrombogenic and antitraumatic blood pump:: The Gyro C1E3 [J].
Takano, T ;
Nakata, K ;
Yoshikawa, M ;
Maeda, T ;
Glueck, J ;
Fujisawa, A ;
Makinouchi, K ;
Yokokawa, M ;
Murabayashi, S ;
Nosé, Y .
ASAIO JOURNAL, 2000, 46 (01) :123-127
[9]   Development of a silicone hollow fiber membrane oxygenator for ECMO application [J].
Yamane, S ;
Ohashi, Y ;
Sueoka, A ;
Sato, K ;
Kuwana, J ;
Nose, Y .
ASAIO JOURNAL, 1998, 44 (05) :M384-M387